Sec. 22-45. - House sewer specifications.

House sewers shall not be less than four (4) inches in diameter, and preferably five (5) or six (6) inches to avoid stoppages. The grade shall be one-quarter inch per foot for four (4) inch sewers and shall not be less than one-eighth inch per foot for larger sizes. House sewers shall be laid with tight joints to a septic tank in a straight line and on a uniform grade. Pipe for such house sewers shall be of cast iron, with leaded joints, to a point at least ten (10) feet beyond the foundation wall of any cellar or basement. Portions of house sewers within seventy-five (75) feet of a well shall be of cast iron, with leaded joints, but no portion of such sewer, however constructed, shall be within twenty-five (25) feet of a well. No sewer shall be located within twenty-five (25) feet of a cellar drain or groundwater drain unless pipe is of cast iron with leaded joints.

(Code 1960, § 7-10)