Sec. 22-50. - Septic tanks—Generally.
(a) Septic tanks shall be provided for water carriage sewage disposal where no public sewers are available. No tank shall be located within ten (10) feet of a house. They shall be constructed with watertight walls and bottom, with inlets baffled or submerged to a depth of twelve (12) to eighteen (18) inches and outlets baffled or submerged to a depth of at least eighteen (18) inches below the surface of liquid in the tank but not more than half the liquid depth. With two-compartment tanks there should be adequate connections about at middepth, and two-thirds or more of the required capacity should be in the first compartment. Septic tanks shall be made with removable covers or manholes so as to provide access to the tank for purposes of cleaning. Cleanout manholes on septic tanks are to be brought up to grade to facilitate inspection and cleaning of tanks; such covers shall be flytight. At least two (2) manholes shall be provided for tanks more than ten (10) feet long and at least one manhole per compartment. No septic tank shall have a liquid capacity of less than seven hundred fifty (750) gallons below the outlet invert. The minimum liquid depth of septic tanks shall be thirty-six (36) inches, measured from the bottom to the invert of the outlet. Septic tanks are to be cleaned out at intervals not to exceed two (2) years. (b) The minimum liquid capacities for more than one family are as follows: Two (2) families, one thousand five hundred (1,500) gallons; three (3) families, two thousand two hundred (2,200) gallons; larger sizes proportional. (c) Where additional capacity is needed, two (2) tanks may be used in series for one installation. No more than two (2) tanks shall be installed in series or parallel but larger tanks shall be used to make up the required capacity. Sometimes sectional units of approved design may be put together to make up what is virtually a single tank although the tank is usually constructed as a complete unit. (d) Houses of new construction may provide for a separate leaching system for kitchen and laundry waste. Such a leaching system may consist of either one or more dry wells. No garbage grinder is to be installed in this system. Drainage from kitchen and laundry is in no way to be connected to the septic tank system for bathroom fixtures. This system is to be placed on lower ground than that for bathroom fixtures wherever feasible and shall be located in accordance with provisions stated in section 22-48. In no event shall this system be higher in elevation than that used for bathroom fixtures.
(Code 1960, § 7-10)
Ask a question about Bristol law
Corpus searches the Bristol sections it holds and shows the ones that match, with their citations. Free, no sign-in.