§ 230-19.2 — IS Institutional Service District
City Code of the City of Milford, Delaware (Supplement 29 Update 1 (2025-01-27)) · Milford City Code § 230-19.2
Corpus is an independent public-information project, not the official City of Milford website. Stable reference: corpuslaw.us/code/c5321b72-9495-4f56-9035-ab32479bc925
§ 230-19.2. - IS Institutional Service District.
A. Purpose. The purpose of the Institutional Service District is to further the public health, safety and welfare by providing a location for schools, governmental buildings and uses, health-care-related uses, a hospital, and all other health-care facilities with appropriate access to public streets, utilities and municipal services, adequate parking areas, and circulation of traffic. This district is created to serve residents of the City of Milford as well as surrounding areas by allowing the existing educational, governmental, hospital and health-care facilities and corresponding supporting uses and structures to expand, in order to meet the growing demand and needs of the community for these above-mentioned uses. This district has been created to establish reasonable standards for such educational, governmental, health-care facilities and services, as well as uses permitted in the R-8 Zoning District. B. Permitted uses. (1) Hospital and all other health-care facilities, including any and all support services related thereto. (2) Outpatient health-care centers and health-care facilities. (3) Professional and medical offices involving the diagnosis, treatment and care of humans, including any and all support services related thereto. (4) Medical laboratories utilized for the diagnosis, treatment, and care of humans. (5) Pharmacies. (6) Heliports. (7) Private education institutions and training centers. (8) Nursing facilities, convalescent homes, and a continued-care retirement communities. (9) Child or adult day-care facilities (including both day-care homes and day-care centers) to accommodate patients, patient families, health-care employers and their employees, and the public. (10) Publicly and privately owned utilities, including supporting structures and uses, including but not limited to water, sewer, electric, communications, fiber optics, natural gas, data and computer processing, and similar uses and structures which reflect and incorporate technological advancements. (11) Cafeteria facilities snack and gift shops, banking facilities, restaurants and retail or personal service shops primarily for the use of health-care employees, patients and visitors. (12) Health-care uses and health-care facilities which reflect and incorporate technological advancements in the health-care industry. (13) Ambulance and emergency rescue services. (14) Maintenance and laundry facilities. (15) Libraries (16) Places of worship. (17) Parking areas, including parking facilities. (18) Publicly owned and/or health-related recreation facilities. (19) Rehabilitation facilities. (20) Government offices, municipal and public services and facilities, including city hall, water storage towers, water reservoirs, pumping stations, water treatment plants, sewerage pumping stations, sewers (storm and sanitary), street rights-of-way, utility transmission and distribution lines, police and fire stations and substations for electric, gas, and telephone facilities. (21) Auditoriums. (22) Modular office units. (23) Overnight accommodations for patient families and individuals that are receiving treatment at the hospital facility. (24) Public and private elementary, junior or senior high schools and colleges. (25) Registered Compassion Center Dispensary. C. Conditional uses subject to special regulations. The following uses may be permitted with the approval of a conditional use permit by the Milford City Council in accordance with the provisions in Article IX of this chapter: (1) All residential uses permitted in the R-8 Zoning District subject to its area regulations. (2) Any residential housing owned, maintained and operated by a health-care organization for the primary benefit of its patients, patient families, students and/or residents and/or health-care employers and their employees. (3) Places of worship. (4) Emergency shelter facility. (a) The lot on which an emergency shelter facility is located shall not be within 500 feet of a lot on which another emergency shelter facility or group home is located. (b) All state licenses and permits for such a facility have been obtained. (5) Community energy generating facility. (a) The footprint of the solar array, as defined as the by the outer limit of the panels and exclusive of buffers shall be no larger than 50 acres in size. (b) No more than one Community Solar Energy Facility (SEF) shall be permitted on a parcel. All separate parcels in existence on June 1, 2023, shall be considered original parcels. Future subdivision of an original parcel shall not enable the development of additional Community Solar Energy Facilities. (c) Facility location and siting shall be in accordance with the requirements of Title 26 Public Utilities of the Delaware Administrative Code, 3001 (Rules for Certification and Regulation of Electric Suppliers) as amended. (d) Setbacks for the Facility shall be: [1] Front setback shall be 75 feet. [2] Side setback shall be 50 feet. [3] Rear setback shall be 50 feet. [4] Distance from any off-site dwelling unit shall be 100 feet. [5] Distance from any State recognized Scenic Byway shall be 150 feet. [6] Distance from any wetlands shall be 100 feet. (e) The site area shall be planted to achieve a minimum six-foot high four-season visual barrier in accordance with the following guidelines: [1] Include a variety of native evergreen trees. Existing native vegetation may be used to achieve the required planted buffer. [2] A minimum of two rows shall be installed and trees shall be planted in staggered rows. Plantings shall be placed at maximum 20 feet apart within the same row and 10 feet apart from the adjacent, staggered row. [3] Include groundcover to minimize growth of invasive species or provide a mowing schedule until the area is fully established in a natural condition. [4] The buffer shall be maintained to prevent disease from spreading and any trees that don't survive shall be replaced. [5] A raised berm with a 1:4 side slope and flat top may be used to achieve minimum height at planting. (f) The required buffer may be counted toward planting requirements included in this Chapter. (g) If topsoil is removed for improvements, it shall remain on the site. (h) Noninvasive, perennial vegetative ground cover must be maintained or established in all areas containing solar arrays and in required setbacks to prevent erosion and manage run-off. A seed mix will be used to promote the growth of a ground cover that is favorable to future use of the land by animals. The height of the vegetation growth shall be maintained as to reduce the possibility of the airborne spreading of weeds and seeds transmitted to other adjacent lands. (i) A soils study establishing the presence of any contaminants shall be completed prior to construction and every five years thereafter. Surface Soil samples shall be collected from the first six inches of soil. One composite sample shall be collected every 5 acres of SEF footprint. The composite sample should be a maximum of 10 aliquots collected from evenly spaced locations throughout the 5-acre footprint. A baseline sample shall be collected prior to the start of the SEF construction. The composite sample should be analyzed for the primary component of the installed solar panel via the prevailing EPA method for Inorganic Compounds. A letter report of findings shall be submitted within 45 days from receipt of the laboratory results to the City and shall include a summary table showing current and past results and the original certified laboratory results. A sketch showing the sample locations should be provided with the letter report. The full report shall be kept on file by the applicant and available for review by the City. If contaminate levels appear to exceed the baseline, the City will forward the report to DNREC to determine appropriate mitigation measures. If the 5 year and 10 year tests do not show material increase in the metal constituents tested, then testing interval may be extended to every 10 years. (j) Signage, not to exceed six square feet, identifying the operator, its contact numbers, 911 address and emergency contact information shall be posted at each entrance or exit of the property. (k) Abandonment. A Community Energy Generating Facility that does not produce energy for a continuous period of one year or more shall be presumed to have been abandoned. The Applicant may request a Good Cause Exemption that may not be unreasonably withheld so long as all Real Estate and Personal Property Taxes are in Good Standing. Any Facility that has been abandoned without attaining a Good Cause Exemption must be decommissioned and removed within 180 days. Decommissioning must consist of: [1] Physical removal of all solar photovoltaic facilities, structures, equipment, security barriers and transmission lines from the site. [2] Recycling or disposal of all solid and hazardous waste in accordance with local, state, and federal regulations. [3] Stabilization or re-vegetation of the site as necessary to minimize erosion. The Planning Director is authorized to allow the owner or operator to leave landscaping or designated below-grade foundations in place in order to minimize erosion and disruption to vegetation and/or agriculture. (l) Decommissioning plan. [1] A decommissioning plan outlining the anticipated means and costs of removing the solar facility must be submitted, with the application. [2] The decommissioning plan should ensure that the owner or operator properly removes the equipment and facilities upon the end of project life or after their useful life. The plan must include provisions for the removal of all structures and foundations, the removal of all electrical transmission components and the restoration of soil and vegetation. [3] The owner/operator must provide a present-day decommissioning cost estimate and identify the parties responsible for decommissioning. (m) Financial Assurance. The operator or property owner shall provide a bond, surety, letter of credit, or other financial assurance in a form and amount acceptable to the Department to secure payment of 100% of the anticipated cost of removal of all associated site improvements and restoration of the site to its pre-development condition. The financial assurance shall remain in full force and effect as long as the solar Facility remains in place. The financial assurance shall be reviewed and renewed every five years to ensure the amount reflects the current market. (6) Energy system utility scale solar & wind. (a) The following are conditions specific to Solar Facilities: [1] Setbacks for a Solar facility shall be: [a] Front setback shall be 100 feet. [b] Side setback shall be 75 feet. [c] Rear setback shall be 75 feet. [d] Distance from any off-site dwelling unit shall be 100 feet. [e] Distance from any State recognized Scenic Byway shall be 150 feet. [f] Distance from any wetlands shall be 100 feet. [2] The required setback shall be planted to achieve a minimum six-foot high four-season visual barrier in accordance with the following guidelines: [a] Include a variety of native evergreen trees. Existing native vegetation may be used to achieve the required planted buffer. [b] A minimum of two rows shall be installed and trees shall be planted in staggered rows. Plantings shall be placed at maximum 20 feet apart within the same row and 10 feet apart from the adjacent, staggered row. [c] Include groundcover to minimize growth of invasive species or provide a mowing schedule until the area is fully established in a natural condition. [d] The buffer shall be maintained to prevent disease from spreading and any trees that don't survive shall be replaced. [e] A raised berm with a 1:4 side slope and flat top may be used to achieve minimum height at planting. [3] A soils study establishing the presence of any contaminants shall be completed prior to construction and every five years thereafter. Surface Soil samples shall be collected from the first six inches of soil. One composite sample shall be collected every 5 acres of SEF footprint. The composite sample should be a maximum of 10 aliquots collected from evenly spaced locations throughout the 5-acre footprint. A baseline sample shall be collected prior to the start of the SEF construction. The composite sample should be analyzed for the primary component of the installed solar panel via the prevailing EPA method for Inorganic Compounds. A letter report of findings shall be submitted within 45 days from receipt of the laboratory results to the City and shall include a summary table showing current and past results and the original certified laboratory results. A sketch showing the sample locations should be provided with the letter report. The full report shall be kept on file by the applicant and available for review by the City. If contaminate levels appear to exceed the baseline, the City will forward the report to DNREC to determine appropriate mitigation measures. If the 5 year and 10 year tests do not show material increase in the metal constituents tested, then testing interval may be extended to every 10 years. [4] Signage, not to exceed six square feet, identifying the operator, its contact numbers, 911 address and emergency contact information shall be posted at each entrance or exit of the property. (b) The following are conditions specific to Wind Facilities: [1] Setbacks for a Wind Facility shall be: [a] Front setback shall be 800 feet. [b] Side setback shall be 800 feet. [c] Rear setback shall be 800 feet. [d] Distance from any off-site dwelling unit shall be 1,000 feet. [e] Distance from any State recognized Scenic Byway shall be 800 feet. [f] Distance from any wetlands shall be 100 feet. [2] No climbing pegs or tower ladders shall be located closer than 12 feet to the ground level at the base of the structure for freestanding single poles. [3] The facility shall be designed to prevent unauthorized external access to electrical and mechanical components and shall have access doors that are kept securely locked. [4] All access roads shall be gated and locked. [5] All power transmission lines from the tower to any other building or other structure shall be located underground to the maximum extent practical. [6] No tower shall be lit except to comply with Federal Aviation Administration requirements. Minimum-security lighting for ground level facilities shall be allowed as approved on the site plan. Security lighting shall be designed to minimize light pollution, including the use of light hoods, low-glare fixtures, and directing lights at the ground. [7] All structures in a project shall be finished in a single, non-reflective, matte color or a camouflage scheme. [8] Signs. [a] No advertising signs are allowed on any part of the WECS, including fencing and support structures. [b] No lettering, company insignia, advertising, or graphics shall be on any part of the tower, hub, or blades. [c] Appropriate warning signs shall be posted. At least one sign shall be posted at the base of the tower warning of electrical shock or high voltage. A sign shall be posted on the entry area of the fence around each tower or group of towers and any building (or on the tower or building if there is no fence) containing emergency contact information, 911 address, including a local telephone number with 24-hour, 7-days-a-week coverage. The City may require additional signs based on safety needs. [9] Noise level shall not exceed 50 dBA, including constructive interference at existing off-site residences, businesses, and public buildings. (c) The following are conditions required for all Utility Solar and Wind Energy Facilities [1] Required buffers may be counted toward planting requirements included in this Chapter. [2] If topsoil is removed for improvements, it shall remain on the site. [3] Noninvasive, perennial vegetative ground cover must be maintained or established in all areas containing solar arrays and in required setbacks to prevent erosion and manage run-off. A seed mix will be used to promote the growth of a ground cover that is favorable to future use of the land by animals. The height of the vegetation growth shall be maintained as to reduce the possibility of the airborne spreading of weeds and seeds transmitted to other adjacent lands. [4] Abandonment. A Utility Solar or Wind Facility that does not produce energy for a continuous period of one year or more shall be presumed to have been abandoned. The Applicant may request a Good Cause Exemption that may not be unreasonably withheld so long as all Real Estate and Personal Property Taxes are in Good Standing. Any Utility Solar Facility that has been abandoned without attaining a Good Cause Exemption must be decommissioned and removed within 180 days. Decommissioning must consist of: [a] Physical removal of all solar photovoltaic facilities, wind turbines, structures, equipment, security barriers and transmission lines from the site. [b] Recycling or disposal of all solid and hazardous waste in accordance with local, state, and federal regulations. [c] Stabilization or re-vegetation of the site as necessary to minimize erosion. The Planning Director is authorized to allow the owner or operator to leave landscaping or designated below-grade foundations in place in order to minimize erosion and disruption to vegetation. [5] Decommissioning plan. [a] A decommissioning plan outlining the anticipated means and costs of removing the facility must be submitted, with the application. [b] The decommissioning plan should ensure that the owner or operator properly removes the equipment and facilities upon the end of project life or after their useful life. The plan must include provisions for the removal of all structures and foundations, the removal of all electrical transmission components and the restoration of soil and vegetation and/or agriculture. [c] The owner/operator must provide a present-day decommissioning cost estimate and identify the parties responsible for decommissioning. [6] Financial Assurance. Prior to final plan approval, the operator or property owner shall provide a bond, surety, letter of credit, or other financial assurance in a form and amount acceptable to the Department to secure payment of 100% of the anticipated cost of removal of all associated site improvements and restoration of the site to its pre-development condition. The financial assurance shall remain in full force and effect as long as the facility remains in place. The financial assurance shall be reviewed and renewed every five years to ensure the amount reflects the current market. D. Area regulations. (1) The minimum area to request an Institutional Service District shall be 20 acres. (2) Maximum lot coverage shall be 75%. (3) Minimum lot width shall be 150 feet. (4) Height of buildings, including any hospital structure existing as of the date of enactment of this section, shall not be greater than 140 feet, excluding smokestacks and/or other rooftop ancillary services (such as heating and air conditioning equipment, staircases, fire escapes or walkways, elevator shafts, enclosed mechanical rooms and similar appurtenances). (5) Minimum front yard setback shall be 50 feet. (6) Side yards shall be a minimum of 50 feet. (7) Minimum rear yard setback shall be 50 feet. (8) Parking shall comply with the requirements provided in Article IV of this chapter. (9) Landscape screening shall comply with the requirements provided in Article V of this chapter. (10) Signs shall comply with the requirements provided in Article VI of this chapter. (11) Accessory structures in aggregate shall occupy no more than 10 percent of the required rear and side yard of the lot area and may not dominate in area, extent or purpose to the principal use or structure. The area of the principal structure shall be calculated using the definition of floor area in this chapter. (12) Accessory structures shall be located in the side and rear lot areas. (13) Accessory structures shall meet the principal use setbacks and shall not be located less than 5 feet from a principal structure.
[Ord. No. 2022-06, 1-24-2022; Ord. No. 2023-28, § 4, 8-14-2023; Ord. No. 2024-11, § 2, 1-13-2025]
Ask a question about Milford law
Corpus searches the Milford sections it holds and shows the ones that match, with their citations. Free, no sign-in.
