Sec. 5-3-9. - Sampling and analytical requirements.

(a) Sampling requirements for users. (1) A minimum of four (4) grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide, and volatile organics. The Assistant Director of Utilities will determine on a case-by-case whether the user will be able to composite the individual grab samples. For all other pollutants, 24-hour composite samples must be obtained through flow-proportional composite sampling techniques where feasible. Augusta may waive flow-proportional composite sampling for any user that demonstrates that flow-proportional is infeasible. In such cases, samples may be obtained through time-proportional composite sampling techniques or through a minimum of four (4) grab samples where the user demonstrates that this will provide a representative sample of the effluent being discharged. (2) Samples should be taken immediately downstream from pretreatment facilities if such exist or immediately downstream from the regulated or manufacturing process if no pretreatment exists or as determined by Augusta and contained in the user's wastewater discharge permit. For categorical users, if other wastewaters are mixed with the regulated wastewater prior to pretreatment the user should measure the flows and concentrations necessary to allow use of the combined wastestream formula of 40 CFR 403.6(e) in order to evaluate compliance with the Applicable Categorical Pretreatment Standards. For other SIUs, for which Augusta has adjusted its local limits to factor out dilution flows, the user should measure the flows and concentrations necessary to evaluate compliance with the adjusted pretreatment standard(s). (3) All sample results shall indicate the time, date and place, of sampling, and methods of analysis, and shall certify that such sampling and analysis is representative of normal work cycles and expected pollutant discharges from the user. If a user sampled and analyzed more frequently than what was required in its wastewater discharge permit, using methodologies in 40 CFR Part 136, it must submit all results of sampling and analysis of the discharge as part of its self-monitoring report. (b) Analytical requirements. All pollutant analyses, including sampling techniques, shall be performed in accordance with the techniques prescribed in 40 CFR Part 136, unless otherwise specified in an applicable categorical pretreatment standard. If 40 CFR Part 136 does not contain sampling or analytical techniques for the pollutant in question, sampling and analyses must be performed in accordance with procedures approved by the EPA. (c) Augusta monitoring of user's wastewater. Augusta will follow the same procedures as outlined in Sections 5-3-9(a) and (b). Additionally, industrial users must ensure that appropriate monitoring devices and methods consistent with approved scientific practices shall be selected and used to ensure the accuracy and reliability of measurements of the volume of monitored discharges. The devices shall be installed, calibrated, and maintained to ensure that the accuracy of the measurements are consistent with the accepted capability of that type of device. Flow monitoring devices shall be capable of measuring flows with a less than 10% error from true discharge rate throughout the expected discharge volumes.

( Ord. No. 6557 , § 1, 10-3-2002)

Ask a question about Augusta-Richmond County consolidated government law

Corpus searches the Augusta-Richmond County consolidated government sections it holds and shows the ones that match, with their citations. Free, no sign-in.