Sec. 8-1-43. - General standards.

In ALL of the Area of Special Flood Hazard the following provisions are required: (a) New construction and substantial improvements of existing structures shall be anchored to prevent flotation, collapse, and lateral movement of the structure; (b) Manufactured homes shall be anchored to prevent flotation, collapse, and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable State requirements for resisting wind forces; (c) New construction and substantial improvements of existing structures shall be constructed with materials and utility equipment resistant to flood damage; (d) New construction and substantial improvements of existing structures shall be constructed by methods and practices that minimize flood damage; (e) All heating and air conditioning equipment and components, all electrical, ventilation, plumbing, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (f) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; (g) New and replacement s sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters; (h) New on-site waste disposal systems shall be located within the Area of Special Flood Hazard per the provisions of the Georgia Onsite Wastewater Regulations; (i) Any alteration, repair, reconstruction or improvement to a structure which is not compliant with the provisions of this Chapter, shall be undertaken only if the non-conformity is not furthered, extended, or replaced; and (j) Elevated structures. All new construction and substantial improvements of existing structures that include ANY fully enclosed area located below the lowest floor formed by foundation and other exterior walls shall be designed so as to be an unfinished or a flood damage-resistant enclosure. For any unfinished or flood-resistant enclosed area below the regulatory flood protection elevation with a height greater than or equal to four (4) feet, the owner must sign Augusta's Non-Conversion Agreement stating that enclosed area shall not be converted to habitable space without obtaining a permit and allowing the Director, or his/her designee, access (at any time) to ensure the enclosed area is not in violation to this Chapter. The owner must record the Non-Conversion Agreement with the deed for use by future owners. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater. (1) A minimum of two (2) openings that are installed no more than twelve (12) inches above the higher of the final interior or exterior grade, and that are installed in at least two different sides (preferably the sides in the direction of the flow of floodwater) of each enclosed area, must be provided, where the openings: (a) Have a total open net area of not less than one square inch for every square foot of enclosed area Openings may be equipped with screens, louvers, valves or other coverings or devices provided they are disabled in the open position and also permit the automatic flow of floodwater in both directions.; or (b) Are individually certified by a design professional licensed to do design work in the State of Georgia stating that the openings are designed to automatically equalize hydrostatic flood loads on exterior walls by allowing the automatic entry and exit of floodwaters in accordance with the American Society of Civil Engineers - Flood Resistant Design and Construction (ASCE 24) and that an appropriate number of vents are provided. A copy of the Engineer's Certification (signed and sealed) along with the applicable section from this Chapter (this section) allowing for the use of these engineered openings must be attached to the Elevation Certificate; or (c) Are ICC-ES accepted engineered flood vents, and the appropriate number of such vents are provided and installed in accordance with the manufacturer's specifications. A copy of the ICC-ES Evaluation Report along with the applicable section from this Chapter (this section) allowing for the use of these engineered flood vents must be attached to the Elevation Certificate. (2) So as not to violate the "Lowest Floor" criteria of this Chapter, the unfinished or flood damage-resistant enclosure shall only be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area; and (3) The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (4) An attached garage may have its floor below the BFE provided the garage meets all of the requirements for an enclosed area below the BFE, including, but not limited to, the installation of openings that meet Section 8-1-43(j)(1) above. Openings may be installed in garage doors; however, garage doors without openings do not meet the requirement for openings. The use of the garage space must be limited to parking of vehicles, building access and storage. Section 8-1-43(j)(3), above, must be strictly adhered to. Flood damage-resistant materials must be used below the BFE and all utilities must be elevated to be three (3) feet above the BFE. (5) Crawlspaces that are below-grade on all sides (basements) are not allowed. (k) Detached garages, detached storage buildings/accessory structures are allowed, without the requirement to elevate to three (3) feet above the BFE in AE zones, or three (3) feet above the Highest Adjacent Grade (HAG) in A zones, if they comply with all of the requirements for enclosures: (a) must be a walled and roofed structure; (b) must be used for parking of vehicles and storage only; (c) must not be larger than one-story in height; (d) must not exceed 600 square feet in size; (e) must have a low flood damage potential; (f) must be constructed of flood damage-resistant materials below the area that is three (3) feet above the BFE, or three (3) feet above the HAG, whichever is applicable; (g) all utilities must be elevated to be three (3) feet above the BFE, or three (3) feet above the HAG, whichever is applicable; (h) must have flood openings that meet the requirements of Section 8-1-43(j)(1), in order to equalize hydrostatic forced on exterior walls by allowing the automatic entry and exit of floodwaters, (i) must be anchored to resist flotation, collapse, and lateral movement under flood conditions; (j) may not store any materials that could negatively react with water or be water-reactive; (k) must agree not to convert, or modify in any manner, the approved use. (l) Development of accessory structures that are not walled and roofed, are not used only for parking or storage, or are larger than one-story in height, or 600 square feet in size, or which have a medium or high flood damage potential, must be designed and constructed to meet or exceed the minimum requirements for structures in SFHAs as set forth in this Chapter; to include any structure that has a human habitation component (apartment, carriage house, guest house, bath house, recreational rooms or game rooms) and structures such as gazebos, pergolas and carports that are not walled and roofed. The property owner may apply for and the City of Augusta may grant, on a case-by-case basis, a variance to allow accessory structures larger than 600 square feet to be wet floodproofed. (m) For parcels of land than have only one structure, that structure is considered the principal structure for floodplain management purposes, even if the structure would otherwise meet the definition for accessory structure based on its size and use. In these cases, the accessory structure must be elevated or dry floodproofed pursuant to the requirement of this Chapter, unless the property owner applies for and is granted a variance to allow the accessory structure to be wet floodproofed. (n) Agricultural structures are allowed, without the requirement to elevate to three (3) feet above the BFE in AE zones, or three (3) feet above the Highest Adjacent Grade (HAG) in A zones, if they comply with all of the requirements for enclosures: (a) must be a walled and roofed structure, silo/grain bin or elevator, or tank; (b) must be larger than 600 square feet; (c) must not be used for human habitation, employment, manufacturing, or entertainment; (d) must be used exclusively for agricultural purposes or uses; (e) must have a low flood damage potential; (f) must be constructed of flood damage-resistant materials below the area that is three (3) feet above the BFE, or three (3) feet above the HAG, whichever is applicable; (g) all utilities must be elevated to be three (3) feet above the BFE, or three (3) feet above the HAG, whichever is applicable; (h) must have flood openings that meet the requirements of Section 8-1-43(j)(1), in order to equalize hydrostatic forced on exterior walls by allowing the automatic entry and exit of floodwaters, (i) must be anchored to resist flotation, collapse, and lateral movement under flood conditions; (j) may not store any materials that could negatively react with water or be water-reactive; (k) may not have any of the following uses: manure storage, livestock confinement operations, liquefied natural gas terminals, and production or storage of highly volatile, or toxic materials. (l) must agree not to convert, or modify in any manner, the approved use. (o) Development of agricultural structures that are not walled and roofed, may be used for human habitation (including worker dormitories), employment, manufacturing or entertainment, or which are not used exclusively for agricultural purposes, or which have a medium or high flood damage potential, must be designed and constructed to meet or exceed the minimum requirements for structures in SFHAs as set forth in this Chapter. (p) On property containing an Area of Special Flood Hazard, all new construction, requiring a Site Plan, must conform to Augusta's Stormwater Management Ordinance and Augusta's Stormwater Management Manual, current edition, which include, but are not limited to, Best Management Practices (BMPs) which control the quality and/or quantity of storm water runoff and which are compatible with the planned land use. (q) As mandated by the State of Georgia, any land determined to be a State Water Buffer, shall be reserved, and shall not be developed, unless expressly permitted by the State of Georgia.

( Ord. No. 7147 , § 1, 9-15-2009; Ord. No. 7282 , § 8-1-43, 9-6-2011; Ord. No. 7574 , § 1(8-1-43), 6-29-2017; Ord. No. 7687 , § 8-1-43, 10-21-2019; Ord. No. 7752 , § 8-1-43, 2-2-2021)

Ask a question about Augusta-Richmond County consolidated government law

Corpus searches the Augusta-Richmond County consolidated government sections it holds and shows the ones that match, with their citations. Free, no sign-in.