§ 8-1-45 — Building standards for streams without established base flood elevations and/or floodways (A-zones)
Code of Ordinances of Augusta-Richmond County, Georgia (Recodification: codified through Ordinance No. 7807, adopted December 7, 2021) · Augusta Code of Ordinances § 8-1-45
Corpus is an independent public-information project, not the official City of Augusta-Richmond County consolidated government website. Stable reference: corpuslaw.us/code/9add7473-0f4a-4106-88a0-a2716501924f
Sec. 8-1-45. - Building standards for streams without established base flood elevations and/or floodways (A-zones).
Located within the Area of Special Flood Hazard established in Article 3, Section 8-1-17, where streams exist but no base flood data have been provided (A-Zones), OR where base flood data have been provided but a Floodway has not been delineated, the following provisions apply: (a) No encroachments, including structures, accessory structures, or fill material, shall be located within an area equal to five (5) times the width of the stream or twenty (20) feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels (flood heights) during the occurrence of the base flood discharge (a No-Rise Certification). (b) In the Area of Special Flood Hazard without Base Flood Elevation data, new construction and substantial improvements of existing structures, to include accessory structures not used solely for parking or storage, pursuant to 8-1-43(l) and 8-1-43(m), shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three (3) feet above the Highest Adjacent Grade at the building site. Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of Article 5, Section 8-1-43(j), "Elevated Structures". (1) All heating and air conditioning equipment and components (including ductwork), all mechanical, electrical, ventilation, plumbing, and other service facilities shall be elevated no less than three (3) feet above the Highest Adjacent Grade at the building site. The Director shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file. (c) When Base Flood Elevation data or floodway data have not been provided in accordance with Article 3, Section 8-1-17, then the Director shall obtain, review, and reasonably utilize any scientific or historic Base Flood Elevation and floodway data available from a Federal, State, or other source, in order to administer the provisions of Article 5. ONLY if data are not available from these sources, then the provisions of (a) and (b) of this Section shall apply.
( Ord. No. 7147 , § 1, 9-15-2009; Ord. No. 7282 , § 8-1-45, 9-6-2011; Ord. No. 7574 , § 1(8-1-45), 6-29-2017; Ord. No. 7687 , § 8-1-45, 10-21-2019; Ord. No. 7752 , § 8-1-45, 2-2-2021)
Ask a question about Augusta-Richmond County consolidated government law
Corpus searches the Augusta-Richmond County consolidated government sections it holds and shows the ones that match, with their citations. Free, no sign-in.