Sec. 8-1-44. - Specific standards.
In the Area of Special Flood Hazard the following provisions are required: (a) New construction and substantial improvements, to include accessory structures not used solely for parking or storage, pursuant to 8-1-43(l) and 8-1-43(m). Where Base Flood Elevation data are available, new construction and substantial improvement of any structure, including manufactured homes, and accessory structures not used solely for parking or storage, shall have the lowest floor, including basement, elevated no lower than three (3) feet above the Base Flood Elevation (also known as the "flood protection elevation"). Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of Article 5, Section 8-1-43(j), "Elevated Structures". (1) All heating and air conditioning equipment and components (including ductwork), all mechanical, electrical, ventilation, plumbing, and other service facilities shall be elevated at or above three (3) feet above the Base Flood Elevation. (b) Non-residential construction. New construction and substantial improvements of non-residential structures may be dry floodproofed in lieu of elevation pursuant to the requirements found in the definition for dry floodproofing found in Article 2, Section 8-1-10. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to three (3) feet above the Base Flood Elevation (also known as the "flood protection elevation"), with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the Director as set forth above and in Article 4, Section 8-1-31(g). (1) All heating and air conditioning equipment and components (including ductwork), all mechanical, electrical, ventilation, plumbing, and other service facilities shall be elevated at or above three (3) feet above the Base Flood Elevation or dry floodproofed to at or above three (3) feet above the Base Flood Elevation. (c) Standards for manufactured homes and recreational vehicles. Where Base Flood Elevation data are available: (1) All manufactured homes placed or substantially improved on: (1) individual lots or parcels, (2) in new or substantially improved manufactured home parks or subdivisions, (3) in expansions to existing manufactured home parks or subdivisions, or (4) on a site in an existing manufactured home park or subdivision where a manufactured home has incurred "substantial damage" as the result of a flood, or "substantial damage" as the result of any origin, must have the lowest floor including basement, elevated no lower than three (3) feet above the Base Flood Elevation (also known as the "flood protection elevation"). (a) All heating and air conditioning equipment and components (including ductwork), all mechanical, electrical, ventilation, plumbing, and other service facilities shall be elevated at or above three (3) feet above the Base Flood Elevation. (2) Manufactured homes placed, or substantially improved in, an existing manufactured home park or subdivision may be elevated so that either: (a) The lowest floor of the manufactured home is elevated no lower than three (3) feet above the level of the Base Flood Elevation (also known as the "flood protection elevation"), or (b) The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than three (3) feet in height above grade. (c) All heating and air conditioning equipment and components (including ductwork), all mechanical, electrical, ventilation, plumbing, and other service facilities shall be elevated at or above three (3) feet above the Base Flood Elevation. (3) All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. (ref. Article 5, Section 8-1-43(b)). (4) All recreational vehicles (the term also includes park trailers, travel trailers, and similar transportable structures) placed on sites must either: (a) Be on the site for fewer than 30 consecutive days. (b) Be fully licensed and ready for highway use, (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions), or (c) The recreational vehicle must meet all the requirements for "New Construction", including the anchoring and elevation requirements of Article 5, Section 8-1-44(c)(1) and (3). (d) Floodway. Located within the Area of Special Flood Hazard established in Article 3, Section 8-1-17, are areas designated as floodway. A floodway may be an extremely hazardous area due to velocity flood waters, debris or erosion potential. In addition, the area must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. Therefore, the following provisions shall apply: (1) Encroachments are prohibited, including earthen fill, new construction, substantial improvements, or other development within the regulatory floodway. Development may be permitted however, provided it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the encroachment shall not result in any increase in flood levels (flood heights) or floodway widths during a base flood discharge (a No-Rise Certification). A registered professional engineer must provide supporting technical data and his/her certification thereof. (2) ONLY if Article 5, Section 8-1-44(d)(1) above is satisfied, then any new construction and substantial improvement shall have the lowest floor, including basement, elevated no lower than three (3) feet above the flood elevation based upon the floodway encroachment, as given by the "With Floodway" column in the Flood Insurance Study Floodway Data Table. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of Article 5, Section 8-1-43(j), "Elevated Structures". All heating and air conditioning equipment and components (including ductwork), all mechanical, electrical, ventilation, plumbing, and other service facilities shall be elevated no lower than three (3) feet above the flood elevation based upon the floodway encroachment, as given by the "With Floodway" column in the Flood Insurance Study Floodway Data Table. (3) The placement of manufactured homes shall be prohibited. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision provided the anchoring standards of § 8-1-43(b) are met, and the elevation standards of § 8-1-44(a) and the encroachments standards of subsection (1) of this Section are met. (4) Removal of trees and other vegetation may not be a consideration in calculating the effect of proposed encroachments on flood levels (flood heights) during the occurrence of the base flood discharge. (5) Accessory structures shall be prohibited in the floodway. (e) Floodway fringe, lower. Within the lower floodway fringe is the area between the floodway and the upper floodway fringe that is lower than a lines one-half (½) the distance between the floodway and the boundary of the Area of Special Flood Hazard. The lower floodway fringe is a transitional area that is hazardous due to its proximity to the floodway and encroachment by fill or development within this area could have serious impact on the entire floodplain. The following provisions shall apply with the lower floodway fringe: (1) Encroachments, including fill, new construction, substantial improvements and other developments shall be prohibited unless certification by a registered professional engineer, with supporting technical data, is provided to the Director demonstrating that encroachments shall not result in any increase in flood levels (flood heights) during occurrence of base flood discharge (a No-Rise Certification). (2) If Article 5, Section 8-1-44(d)(1) is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of Article 5. (3) The placements of manufactured homes, except in an existing manufactured home park or subdivision, shall be prohibited. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision provided the anchoring standards of Article 5, Section 8-1-43(b), and the elevation standards of Article 5, Section 8-1-44(a), and the encroachment standards of Article 5, Section 8-1-44(d)(1) are met. (4) Removal of trees and other vegetation may not be a consideration in calculating the effect of proposed encroachments on flood levels (flood heights) during the occurrence of the base flood discharge. (5) The placement of an accessory structure shall only be allowed if, at the discretion of the Director, or Direction of Engineering, it is deemed to have a low flood damage potential. All requirements of 8-1-43(k) must be met. (f) Large tracts. If a tract contains over one (1) acre located within the Area of Special Flood Hazard, then development or land disturbance on that portion of the tract located within the Area of Special Flood Hazard shall comply with the standards for lower floodway fringe set forth in § 8-1-44(e). (g) Other area unsuitable for development. Land subject to flooding that is not located within a mapped Area of Special Flood Hazard may, at the discretion of the Director or Director of Engineering, be required to comply with any or all standards set forth in this Chapter. (h) Grading in the area of special flood hazard. Grading (including excavating, filling, or any culmination thereof) shall be prohibited in the Area of Special Flood Hazard except for the following: (1) Minimum land disturbing activities such as home gardens and individual home landscaping, repairs, maintenance work and other related activities; (2) Agricultural practices involving the establishment, cultivation, or harvesting of products of the field or orchard, preparing and planting of pasture land, forestry land management practices including harvesting (where stumps are not removed), farm ponds, dairy operations, livestock and poultry management practices and the construction of farm buildings. (3) Projects permitted by or carried out under the technical supervision of the U.S. Department of Agriculture, U.S. Army Corps of Engineers, or any other agency of the U.S. Government; (4) Cemetery graves; (5) Excavation for wells or tunnels or utilities; (6) Approved mining, quarrying, stockpiling of rock, sand, gravel, aggregates, or clay where established and provided for by law; (7) Exploratory excavations under the direction of soils engineers or engineering geologists; (8) Where consistent with other provisions of this Chapter, minimum grading for land development or construction which does not result in topographic changes greater than two (2) feet at any location and which is not for the sole purpose of elevating structures pursuant to Article 5, Section 8-1-44(a) and Article 5, Section 8-1-44(b) of this Chapter. In no case, shall fill be transported into the Area of Special Flood Hazard. (a) Detention ponds and retention ponds are exempt from the provisions 8-1-44(h)(8), provided it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the encroachment by the detention pond or retention pond shall not result in any increase in flood levels (flood heights) or floodway widths during a base flood discharge (a No-Rise Certification). A registered professional engineer must provide supporting technical data and certification thereof. (1) Under no circumstances shall a detention pond or a retention pond be located in the Area of Special Flood Hazard. (9) Construction activities at existing Industrial Sites which were developed before the effective date of the FIRST Floodplain Management Ordinance adopted by Augusta, GA as a basis for Augusta's participation in the National Flood Insurance Program (NFIP), such as dikes, ditches and ponds. (i) As-built drawings and certification. Within the Area of Special Flood Hazard, as-built drawings and certifications shall be provided by a registered professional engineer and/or a registered land surveyor pursuant to 8-1-30(b) and 8-1-44(b) of this Chapter and also when required by the Site Plan Regulations or the Subdivision Regulations. As-built drawings and certifications may be required in other situations at the discretion of the Director. (j) Accessory structures. For floodplain management purposes, accessory structures must only be used for parking or storage, be not larger than one-story and not greater than 600 square feet in size, represent a minimal investment by the property owner, and have low flood damage potential. Development of accessory structures that are not used only for parking or storage, or are larger than one-story in height, or 600 square feet in size, or which have a medium or high flood damage potential, must be designed and constructed to meet or exceed the minimum requirements for structures in SFHAs as set forth in 8-1-44(a); this would include any structure that has a human habitation component (apartment, carriage house, guest house, bath house, recreational rooms or game rooms) and structures such as gazebos, pergolas and carports that are not walled and roofed. Pursuant to 8-1-43(m), when a parcel of land has only one structure, that structure is considered the principal structure for floodplain management purposes, even if the structure would otherwise meet the definition for accessory structure based on its size and use. In these cases, the accessory structure must be elevated pursuant to 8-1-44(a) or dry floodproofed pursuant to the requirements of 8-1-44(b), unless the property owner applies for and is granted a variance to allow the accessory structure to be wet floodproofed. (k) Agricultural structures. For floodplain management purposes, agricultural structures must larger than 600 square feet and must be only be used for agricultural purposes, or uses in connection with the production, harvesting, storage, raising, or drying of agricultural commodities and livestock. Structures used for human habitation and those that are places of employment or entertainment, and structures with multiple or mixed purposes, do not satisfy the "exclusive use" requirement as described in this definition. Development of agricultural structures that are not walled and roofed, may be used for human habitation (including worker dormitories), employment, manufacturing or entertainment, or which are not used exclusively for agricultural purposes, or which have a medium or high flood damage potential, must be designed and constructed to meet or exceed the minimum requirements for structures in SFHAs as set forth in this Chapter.
( Ord. No. 7147 , § 1, 9-15-2009; Ord. No. 7282 , § 8-1-44, 9-6-2011; Ord. No. 7574 , § 1(8-1-44), 6-29-2017; Ord. No. 7687 , § 8-1-44, 10-21-2019; Ord. No. 7752 , § 8-1-44, 2-2-2021)
Ask a question about Augusta-Richmond County consolidated government law
Corpus searches the Augusta-Richmond County consolidated government sections it holds and shows the ones that match, with their citations. Free, no sign-in.