§ 6.11.05 — Storm Drainage System Design

Code of Ordinances of the City of Kennesaw, Georgia (Codified through Ordinance No. 2026-06, enacted March 2, 2026. (Supp. No. 37)) · Kennesaw Municipal Code, App. A, ch. 6, § 6.11.05

Corpus is an independent public-information project, not the official City of Kennesaw website. Stable reference: corpuslaw.us/code/645e5e16-699a-4605-bb5a-f71a574afd11

6.11.05 - Storm Drainage System Design.

Standards to be used in designing system: A. Sizing and location of all drainage structures shall be the responsibility of a registered design professional subject to approval by the Public Works Director or his/her designee. B. Storm drainage pipes shall be sloped to maintain a minimum flow velocity of three (3) feet per second (fps) so sediment will not collect. Exit velocities of eight (8) fps or greater from outlet headwalls will require energy dissipation devices beyond the normal six (6) times diameter length of rip-rap. Unimproved ditch velocities shall be maintained below five (5) fps velocity. C. Storm drainage pipes shall be sloped at a minimum of one percent (1%). Maximum slopes for concrete storm drainage pipes shall be ten percent (10%). Storm drainage pipes on grades steeper than ten percent (10%) shall outfall into a drop structure with a least one (1) section of outlet pipe sloped on greater than two percent (2%) (drop structures must be properly anchored down). D. Georgia Department of Transportation (GDOT), current Roadway and Bridge Standard Plan 1030D, shall be used in determining class (RCP) or gauge (CMP) of pipe under fill and method of back-filling, subject to the stipulations contained herein. E. Inlet spacing shall be performed using FHWA's HEC-12 software or approved alternate. F. Minimum design allowance for inlet clogging is fifteen percent (15%). G. Manning's roughness coefficient ("n"-value) for pavement inlet-design shall be no smaller than 0.016. H. Gutter spreads shall be limited to one-half (½) the travel lane or eight feet (8'), whichever is less. Drainage formula used in determining size of drainage structure shall be determined by the design professional. I. The Rational Method shall use the twenty-five (25) year storm or rain event as the minimum design frequency. Stormwater handled in this manner shall be water internal to the specific subdivision only. J. The Flood Damage Prevention Ordinance (Section 3.02.00) designates each headwater pool created during a one hundred (100) year storm as a one hundred (100) year floodplain equal to the one hundred (100) year floodplain as established and designated by FEMA. K. All subdivision drainage systems, both piped and channelized, receiving stormwater from off-site (outside the bounds of the subdivision specific) shall be designed to handle and transport through the subdivision the one hundred (100) year storm. This design must address all necessary adjustments to channels, pipe sizes, lots, and any infrastructure of the subdivision specific. L. Catch basins and/or drop inlets shall be designed by the developer's engineer to the GDOT Standard Plans 1033D, 1034D, 1019 and subject to final approval by the City of Kennesaw Stormwater Management Division. M. Grated inlets in unpaved areas are not recommended. Raised lid area drains are preferred in unpaved areas. N. Catch basins in accepted subdivisions handling street water shall be designed to handle a ten (10) year storm considering bypass, as prescribed in FHWA's Hydraulic Engineering Circular 12 (HEC-12). Maximum allowable gutter spread shall be one-half (½) the travel lane width or eight feet (8'), whichever is less. O. Catch basins outside of accepted subdivisions handling street water shall be designed to handle a ten (10) year storm considering bypass, as prescribed on the major collectors by the GDOT design requirements. Maximum allowable gutter spread shall be one-half (½) the travel lane width or eight feet (8'), whichever is less. P. Maximum inlet spacing, unless a different spacing is supported by design calculations approved by the Public Works Director or his or her designee, shall not exceed the following: 1. Five hundred feet (500') on grades up to seven percent (7%); 2. Four hundred feet (400') on grades from seven percent (7%) to ten percent (10%); 3. Two hundred fifty feet (250') on grades over ten percent (10%). Q. Demonstration shall be made that the one hundred (100) year storm event runoff will track through the development along the drainage routes assigned by the site specific hydrology study. R. A certification of the pipe specifications for each pipe shall be required before installation.

(Ord. No. 2012-03, 5-7-12)

Ask a question about Kennesaw law

Corpus searches the Kennesaw sections it holds and shows the ones that match, with their citations. Free, no sign-in.