For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3-11-11 — Service building and community service facilities

Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Code of Ordinances § 3-11-11

Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/836f8f7a-ee12-4db6-89f1-fee76f215463

3-11-11. - Service building and community service facilities.

A. General requirements. The requirements of this section shall apply to service buildings, recreation buildings and other community service facilities such as: 1. Management offices, repair shops and storage areas; 2. Sanitary facilities; 3. Laundry facilities; 4. Indoor recreation areas; 5. Commercial uses supplying essential goods or services for the exclusive use of park occupants. B. Service buildings. Every trailer court that accepts or accommodates dependent trailer coaches shall provide adequate flush type toilet fixtures and laundry facilities. In no instance shall there be less than one (1) laundry unit, two (2) water closets, one (1) lavatory and one (1) shower or bathtub for women and one (1) shower or bathtub for men. The foregoing listed facilities shall be the minimum required facilities to accommodate up to twenty (20) dependent trailer coaches. One additional water closet for each sex shall be provided for every ten (10) additional dependent trailer coaches. (Urinals may be substituted for one-third (⅓) of the additional water closets.) One (1) additional lavatory for each sex shall be provided for every ten (10) additional dependent coaches; and one additional shower or bathtub for each sex for every twenty (20) additional dependent coaches. Dependent trailer coaches shall be parked not more than two hundred (200) feet from the service buildings. There shall be one (1) laundry tray for every twenty (20) dependent trailer coach spaces. One (1) shall be located at least fifteen (15) feet or more from any trailer coach space. C. Structural requirements for buildings. 1. Compliance with state and local regulations. The structure shall conform to all rules and regulations of the state codes and codes of the city. All portions of the structure shall be properly protected from destructive elements. Exterior portions shall be of such materials and be so constructed and protected as to prevent entrance or penetration of moisture and weather. 2. Sanitary or laundry facilities. All rooms containing sanitary or laundry facilities shall: a. Have sound resistant walls extending to the ceiling between male and female sanitary facilities. Walls and partitions around showers, bathtubs, lavatories and other plumbing fixtures shall be constructed of dense, nonabsorbent, waterproof material or covered with moisture resistant material. b. Have at least one (1) window or skylight facing directly to the outdoors. The minimum aggregate gross area of windows for each required room shall be not less than ten (10) percent of floor space served by them. Such openings shall be adequately screened. c. Have at least one (1) window which can be easily opened, or a mechanical device which will adequately ventilate the room, such opening or openings shall be adequately screened, to prevent access of insects. 3. Toilets and shower stalls. Toilets shall be located in separate compartments equipped with self-closing doors. Shower stalls shall be of the individual type. The rooms shall be screened, to prevent direct view of the interior when the exterior doors are open. 4. Illumination. Illumination levels shall be maintained as follows: a. General seeing tasks, five (5) foot-candles; b. Laundry room work area, forty (40) foot-candles; c. Toilet room, in front of mirrors, forty (40) foot-candles. 5. Hot and cold water. Hot and cold water shall be furnished to every lavatory, sink, bathtub, shower and laundry fixture, and cold water shall be furnished to every water closet and urinal. 6. Heating facilities. Have adequate heating facilities to maintain a temperature of seventy degrees Fahrenheit (70°F) during cold weather, and to supply a minimum of three (3) gallons of hot water per hour per coach space during time of peak demand. D. Barbecue pits, fireplaces, stoves and incinerators. Cooking shelters, barbecue pits, fireplaces and incinerators shall be so located, constructed, maintained and used as to minimize fire hazards and smoke nuisance both on the property on which used and on neighboring property. No open fire shall be permitted except in facilities provided. No open fire shall be left unattended. No fuel shall be used and no material burned which emits dense smoke or objectionable odors.

(Ord. 207, 6-1971)

Ask a question about Meridian law

Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.