3-11-14. - Fuel supply and storage.
A. Natural gas system. 1. General requirements. Natural gas piping systems shall be installed and maintained in accordance with applicable codes and regulations governing such systems. 2. Manual shutoff valve. Each mobile home lot provided with piped gas shall have an approved manual shutoff valve installed upstream of the gas outlet. The outlet shall be equipped with an approved cap to prevent accidental discharge of gas when the outlet is not in use. B. Liquefied petroleum gas systems. 1. General requirements. Liquefied petroleum gas systems shall be installed and maintained in accordance with applicable codes and regulations governing such systems. 2. Safety devices. Systems shall be provided with safety devices to relieve excessive pressures and shall be arranged so that the discharge terminates at a safe location. 3. Means of shutting off gas. Systems shall have at least one (1) accessible means for shutting off gas. Such means shall be located outside the mobile home and shall be maintained in effective operating condition. 4. Protection of piping against injury. All LPG piping outside of the mobile homes shall be well supported and protected against mechanical injury. Undiluted liquefied petroleum gas in liquid form shall not be conveyed through piping equipment and systems in mobile homes. 5. Gas containers. Liquefied petroleum gas containers installed on a mobile home lot shall be securely but not permanently fastened to prevent accidental overturning. Such containers shall not be less than five (5) nor more than two hundred (200) U.S. gallons gross capacity. 6. Installation restrictions. No liquefied petroleum gas vessel shall be stored or located inside or beneath any storage cabinet, carport, mobile home or any other structure, unless such installations are approved by the City Council and placed fifteen (15) feet or more from any adjacent lot line. C. Fuel oil supply systems. 1. General requirements. All fuel oil supply systems shall be installed and maintained in accordance with applicable codes and regulations governing such systems. 2. Piping installation. All piping from outside fuel storage tanks or cylinders to mobile homes shall be permanently installed and securely fastened in place. 3. Fastening of and location of tanks. All fuel oil storage tanks or cylinders shall be securely fastened in place and shall not be located inside or beneath any mobile home or less than five (5) feet from any mobile home exit. 4. Tanks subject to traffic. Storage tanks located in areas subject to traffic shall be protected against physical damage.
(Ord. 207, 6-1971)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.