Sec. 29.5-3.13. - Protection by elevating.

A building allowed to be protected from flooding by being elevated shall comply with the following: (a) The building or development shall be elevated on stilts, piles, walls, crawl space, or other foundation that is permanently open to flood waters and not subject to damage by hydrostatic pressures of the base flood or 100-year frequency flood. The permanent openings shall be no more than one foot above grade, and a minimum of two (2) openings having a total net area of not less than one square inch for every one square foot of enclosed area subject to flooding shall be provided, unless an alternate design is certified by a professional engineer. (b) The foundation and supporting members shall be anchored and aligned in relation to flood flows and adjoining structures so as to minimize exposure to known hydrodynamic forces such as current, waves, ice, and floating debris. (c) All areas below the flood protection elevation shall be constructed of materials resistant to flood damage. The lowest floor (including basement) and all electrical, heating, ventilating, plumbing, and air conditioning equipment and utility meters, shall be located at or above the flood protection elevation. Water and sewer pipes, electrical and telephone lines, submersible pumps, and other waterproofed service facilities may be located below the flood protection elevation. Gravity storm and sanitary sewer connections are specifically prohibited. Overhead sewers are required for sanitary connections and sump pumps, and for storm sewer connections. (d) No area below the flood protection elevations shall be used for storage of items or materials. (e) When the building wall encloses open space that is below the base flood elevation, gravity storm and sanitary sewer connections are specifically prohibited and overhead sewers are required for the sanitary connections and sumps for the storm sewer connections. (f) Manufactured homes and travel trailers to be installed on a site for more than one hundred eighty (180) days shall be elevated at or above the flood protection elevation and shall be anchored to resist flotation, collapse, or lateral movement by being tied down in accordance with the rules and regulations for the Illinois Mobile Home Tie-Down Act issued pursuant to 77 Ill. Adm. Code 870.

(C.B. No. 97-265, § 1, 10-7-97)

Ask a question about Champaign law

Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.