For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-29-1204.4.11.5 — Hair and lint strainer

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-1204.4.11.5

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/d8cbbe60-557f-44cf-b1ca-096851492cbf

18-29-1204.4.11.5 Hair and lint strainer.

A hair and lint catcher or strainer shall be installed on the suction side of the circulation pump to prevent hair, lint and other extraneous material from reaching the pump filters. Hair and lint catchers shall be so designed that they can be easily dismantled for cleaning and inspection and shall be so located as to be easily accessible for cleaning. The design features shall be as follows: Water passes through the strainer from the outside; the strainer is made of non-corrosive material; the width or diameter of the miner openings is not more than 1/8 inch (3 mm); the area of the strainer openings shall be at least five times the cross-sectional area of the inlet pipe to the strainer. (Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)