18-29-1204.4.11.6 Pressure filters.

Recirculating systems shall contain rapid pressure filters. Sufficient filter area shall be provided to filter the entire contents of the pool in six hours at the rate of not more than 3 gallons per minute per square foot (2 L/s/m2) of filter area. The filter backwashing facilities shall be sufficient to backwash at the rate of 15 gallons per minute per square foot (10 L/s/m2) of filter area. All backwash water and effluents shall be discharged to the sewer through an indirect connection. Pressure filters shall be equipped with readily accessible air relief valves, loss of head or pressure gauges on the inlet and outlet pipes, and an access head or hole large enough to permit inspection, maintenance and repair work. Sight glasses that can be easily removed for cleaning shall be provided in the effluent line from the filter units. (Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)