§ 18-29-905.7 — Vent for future fixtures

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-905.7

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/18faa426-9d3b-4f12-93f7-b5ea9d8337a1

18-29-905.7 Vent for future fixtures.

Where the drainage piping has been roughed-in for future fixtures, a rough-in connection for a vent shall be installed a minimum of one-half the diameter of the drain, but not less than the minimum size indicated in Table 18-29-916.1. The vent rough-in shall connect to the vent system. The connection shall be identified to indicate that the connection is a vent.