Sec. 22-217. - Refrigerant discharge.

(a) Where the discharge of a refrigerant from a pressure-relief valve to the outside atmosphere is required, the discharge pipe outlet shall be not less than 12 feet above the ground and not closer than ten feet to any opening in a building or closer than 20 feet to any fire escape and shall be turned downward. The discharge pipe shall be not less than the size of the relief device outlet. (b) Where ammonia is used in a class B or C system, refrigerant may be discharged into a tank of water which shall be used for no purpose except ammonia absorption. At least one gallon of fresh water shall be provided for every one pound of ammonia in the system. The water used shall be prevented from freezing without the use of salt or chemicals. The bank shall be substantially constructed of not less than one-eighth inch steel. No horizontal dimension shall be greater than one-half the height. The tank shall have a hinged cover or, if closed, shall have a vent of ample capacity at the top of the tank only. The discharge pipe for the pressure-relief valve shall be equipped with a diffuser and shall discharge the ammonia near the bottom of the tank. (c) An emergency relief valve on a system using ammonia shall discharge into such tank of water or into an ammonia mixer consisting of a closed cylinder designed for 50 pounds per square inch working pressure with ammonia and water inlet connections and a valveless connection to the sewer, so arranged that the ammonia will be completely absorbed before leaving the mixer. The connection shall be so arranged that it is impossible to operate the hand-operated ammonia relief valve without first opening the valve supplying the water to the ammonia mixer. (d) Relief devices located on the pressure vessels may be vented to the low pressure side of a system, provided, however, that the low pressure side is equipped with a relief device vented to the atmosphere. (e) Discharge from more than one relief valve may be run into a common header, the area of which shall be equal to the area required for the total refrigerating capacity of all the vessels.

(Ord. of 7-19-1948, § 70; Code 1958, § 28-38)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.