For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 42-2 — International Fire Code and NFPA 101, Life Safety Code Adopted

Code of Ordinances of the Town of Cicero, Illinois (Codified through Ordinance No. 71-25, adopted September 23, 2025. (Supp. No. 122)) · Cicero Municipal Code § 42-2

Corpus is an independent public-information project, not the official City of Cicero website. Stable reference: corpuslaw.us/code/efa0ac92-dd66-4d76-9e43-ad2b71117f15

Sec. 42-2. - International Fire Code and NFPA 101, Life Safety Code Adopted.

For purposes of this Section "Fire Amendments" shall mean the additions, insertions, deletions and changes made to the International Fire Code, 2024 Edition, a copy of which is on file with the Town Clerk. The Town hereby adopts, by reference as if fully set forth in this Code, the International Fire Code, 2024 Edition, including all Appendix Chapters and regulations thereto, as published by the International Code Council, Inc., excepting those provisions that are modified or deleted by the Fire Amendments and as otherwise provided in this Section. The International Fire Code, 2024 Edition and the Fire Amendments shall regulate and govern the safeguarding of life and property from fire and explosion hazards arising from the storage, handling and use of hazardous substances, materials and devices, and from conditions hazardous to life or property in the occupancy of buildings and premises and shall provide for the issuance of permits and collection of fees therefor. At least one copy of the International Fire Code, 2024 Edition and the Fire Amendments are on file in the Office of the Town Clerk and are available for public use, inspection and examination. If any provision of the International Fire Code, 2024 Edition or the Fire Amendments is in conflict with any provision of any code, ordinance, rule or regulation of the Town, the more stringent regulation will apply; provided, however, the Cicero Building Commissioner and/or the Cicero Fire Chief may waive the more stringent requirement if said waiver would be beneficial to the health, safety or welfare of the Town or its residents. NPFA 855: Standard for The Installation of Stationary Energy Storage Systems is hereby adopted. All energy storage systems (ESS) may be installed only on the exterior of structures and shall not be permitted to be installed or retrofitted into any interior of any structure. The Fire Amendments shall be as follows: 1. Section 902.1 (Attachment NN) shall be amended to add the following definition: Fire Area as Related to Fire Sprinkler System Requirements. The aggregate floor area bounded by the exterior walls of a building, regardless of fire walls, fire barriers, or fire resistance-rated horizontal assemblies for applying fire sprinkler installation requirements. 2. Section 903.2 (Attachment OO) shall be amended to state the following: All buildings of all use groups, other than one, two, and three family dwellings, greater than 1500 of square footage shall be protected with an automatic fire sprinkler system installed per NFPA 13. Provide all spec warehouse buildings (use groups S or F) with a ceiling roof height of 25 feet or greater to be protected with an ESFR fire sprinkler system or a hydraulically calculate system for class IV commodities with rack storage calculated to the greatest storage height. All sprinkler systems shall be electronically supervised by a fire alarm system. 3. Section 903.2.1—903.2.12 (Attachment PP) is hereby deleted. 4. The following language shall be added as the last sentence in Section 903.3.5 (Attachment QQ): Hydrant water flow data used for the design of any sprinkler system shall be no more than 1 year old. 5. The following shall serve as Section 903.4.2.1 (Attachment QQ): Fire Department Supervision: Where required by the Code Official to protect from hazards to life and property, the fire alarm system shall terminate at the Fire Department Communications Center. 6. The following shall serve as Section 903.4.3.1 (Attachment QQ): Provide an outside audio/visual device over the Fire Department Connection. 7. The following shall serve as Section 903.4.3.2 (Attachment QQ): (a) Alarm indicating Appliances audio/visual devices: Shall be provided, seen and heard in all areas of every building per NFPA 72. (b) All sprinklered buildings shall be provided with occupant notification devices. This will provide full building notification per NFPA 72. 8. The following shall serve as Section 903.5.1 (Attachment QQ): Fire sprinkler system inspectors test valves shall be accessible at all times and located no more than 6 feet above the finished floor. On multiple riser systems test valves shall be marked as to which riser and area it tests. 9. Section 903.3.9 (Attachment QQ) shall be amended revising the last sentence of said Section to read as follows: … on each floor in multiple storybuildings, provide floor control valves with water flow switches for each floor. 10. The following shall serve as Section 903.4.4 (Attachment QQ): Automatic Sprinklers: Where automatic sprinkler provide protection to an area with an approved flow switch interconnected to the fire alarm system, and the area is easily identifiable as to the location of the activation, additional automatic detectors are not required. When a building has numerous rooms protected by the zoned sprinkler system, the Fire Department may require additional smoke detectors for a more rapid means to identify the location of smoke or fire. 11. The following shall serve as Section 903.3.5.3 (Attachment QQ): Provide a minimum 10% or 5 psi minimum safety factor in the fire protection system hydraulic nameplate. 12. The following shall serve as Section 903.7 (Attachment QQ): By each hydraulically calculated area, on each drawings, provide a copy of the hydraulic nameplate. 13. The following shall serve as Section 903.8 (Attachment QQ): All references to NFPA standards are to be considered part of this Code. 14. The following shall serve as Section 903.9 (Attachment QQ): Fire sprinkler system; Fire pump test header. a. Add-provide an OS&Y control valve on all fire pump test headers. b. Provide an outside test header on fire pump installations. 15. The following shall serve as Section 903.10 (Attachment QQ): Private fire hydrants: Fire hydrants shall be provided around the perimeter of the building in 300' increments. Also a fire hydrant shall be located within 100' of the fire department connection on the fire protection water supply to the building. 16. The following shall serve as Section 903.11 (Attachment QQ): Provide an outside access door to the sprinkler riser valve room and fire pump room. 17. The following shall serve as Section 903.12 (Attachment QQ): In all warehouse storage areas exceeding 20,000 square feet, and where storage exceeds 12' high, provide inside 2½" fire hose valves with 1½" reducer to a 1½" connection. Locate the valves at each door entrance to the warehouse and/or storage area. Provide additional 2½" fire hose valves so that no portion of the warehouse and/or storage area is more than 120' maximum travel distance to a fire hose valve. Show the location of all obstructions and/or racks on the drawing. The fire hose valves system piping shall be: a. A separate riser piping system. b. The 2½" valves shall be supplied by a minimum of 4" with 2½" drops to each valve. c. Where system pressures exceed 100 psi provide Potter reduced pressure field adjustable type valves. 18. Section 905.3.1(Attachment RR) shall be amended to require standpipes in all buildings over three stories high or more than two stories below grade. 19. Section 907.2 through and including 907.2.7.2 and all related exemptions (Attachment SS) are hereby deleted in their entirety and replaced as set forth herein. 20. The following shall serve as Section 907.2: a. Where required: An approved manual, automatic or manual and automatic fire alarm system shall be provided in all Use Groups including occupant notification appliances throughout the building installed per NFPA 72. b. 907.2.1. The specific requirements in the IFC sections 907.2.1, 907.2.2.1, and 907.2.6 for Use Groups A, B and I shall remain. c. Exception: Single Family Homes. d. An approved automatic fire detection system shall be installed in all Use Groups (except single family homes), not provided with an automatic sprinkler system, and in accordance with NFPA 72. Devices, combination of devices, appliances, and equipment shall comply with section 907.1.2. The automatic fire detectors shall be smoke detectors, except that an approved alternative type of detector shall be installed in spaces such as boiler rooms where during normal operations products of combustion are present in sufficient quantity to activate smoke detector. e. All fire alarm control panels or full function annunciator panels shall be installed within 10 feet of the main entrance, or in location approved by the Fire Department. 21. The following shall serve as Section 907.2.1 (Attachment SS): Multi-tenant Use Group M buildings will be "ring by tenant" activated by the fire sprinkler system flow switch for that space or automatic fire detection and shall include a weatherproof clear outside strobe over the entrance to each tenant space as directed by the Fire Department. All outside strobes shall be 75 candela minimum. 22. Section 912.3 (Attachment TT) shall be revised as follows: All Fire Department connections shall be a 4" Storz connection with a 30 degree downturn.

(Code 1958, § 15-1; Ord. No. 31-77, 9-13-1977; Ord. No. 7-87, § 1, 3-24-1987; Ord. No. 94-12, § 3.18, 12-11-2012; Ord. No. 15-15, § 3.06, 2-24-2015; Ord. No. 12-26, § 3.03, 3-24-2026)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.