Sec. 42-26. - Combustible fibers.

(a) Definition. As used in this section, the term "combustible fibers" shall include cotton, sisal, henequen, ixtle, jute, hemp, tow, cocoa fibre, oakum, baled waste, kapok, hay, straw, Spanish moss and excelsior. (b) Storage. Storage of combustible fibers shall be subject to the following: (1) Loose fibers not in suitable bales or packages, whether housed or in the open, shall not be stored within 100 feet of any building except as specified in this section. (2) Quantities not exceeding 100 cubic feet of loose combustible fibre may be kept in any building, provided storage is in a metal lined wooden bin, equipped with a self-closing metal lined cover. (3) Quantities exceeding 100 cubic feet of loose combustible fibre, but not exceeding 500 cubic feet, may be stored in rooms or compartments having floors, walls and ceilings constructed of material possessing fire resistance to withstand a standard one-hour fire test. For this purpose, construction consisting of one-half inch approved asbestos or plasterboard covered with sheetmetal and securely fastened by two-inch nails will be considered satisfactory. Openings into such rooms or compartments shall be cut off from other parts of the building by approved fire doors. (4) Quantities exceeding 500 cubic feet of loose combustible fibre may be stored in approved vaults, constructed as follows: a. Storage vaults shall preferably be located outside of buildings. If located inside, safety vents to outside air shall be provided. b. Walls, floors, and ceilings shall be constructed of brick or other approved noncombustible material. Roofs of outside vaults shall likewise be of noncombustible material, but may be so constructed as to readily give way if an internal explosion occurs. c. Openings, if any, between the vault and main building shall be protected on each side of the wall by an approved fire door. Wall openings in outside vaults exposing other property, not sufficiently detached to be considered cut off, shall be protected by approved fire doors or the equivalent. d. Vaults located within buildings and exceeding 1,000 cubic feet storage capacity shall be protected by approved automatic sprinklers, if possible. Where such protection is not available, steam jets or inert gas systems approved for fire extinguishing shall be installed. (5) Quantities not exceeding 2,500 cubic feet of loose fibre may be stored in a detached loose house, suitably located, with openings properly protected against entrance of sparks. The loose house shall be used for no other purpose.

(Ord. of 9-22-1933, §§ 165—168; Code 1958, §§ 15-34, 15-35)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.