§ 42-31 — Smoke and Carbon Monoxide Detectors in Residential or Mixed Occupancy Buildings

Code of Ordinances of the Town of Cicero, Illinois (Codified through Ordinance No. 71-25, adopted September 23, 2025. (Supp. No. 122)) · Cicero Municipal Code § 42-31

Corpus is an independent public-information project, not the official City of Cicero website. Stable reference: corpuslaw.us/code/69ebb832-7d2c-4bad-8fbd-d22e64685168

Sec. 42-31. - Smoke and Carbon Monoxide Detectors in Residential or Mixed Occupancy Buildings.

(a) Required. All buildings of residential or mixed occupancy having any residential units shall be equipped with approved operable smoke detectors in the manner prescribed in this section. (b) Location. Not less than one approved smoke detector shall be installed in each single-family residential unit and multiple-dwelling unit as defined in the comprehensive zoning ordinance in appendix A to this Code. A detector shall be installed on the ceiling and at least six inches from any wall or on a wall located not less than six inches or more than 12 inches from the ceiling and within 15 feet of all rooms used for sleeping purposes, with not less than one detector per living level. (c) Stairwell installation. All multiple dwellings and buildings of mixed occupancy having any residential units shall contain not less than one approved smoke detector at the uppermost ceiling of all interior stairwells. All such approved smoke detectors required shall be installed on the ceiling at least six inches from the wall or on a wall located not less than six inches or more than 12 inches from the ceiling. (d) Standards. All approved smoke detectors required in this Section shall be either ionization chamber or photoelectric type and shall comply with all the specifications of the Underwriters' Laboratories, Inc., Standard UL 217 (Standard for Safety—Single and Multiple Station Smoke Detectors 1976) and any applicable provisions of the Electrical Code. (e) Exception. This section shall not be applicable in a building that is equipped with an approved automatic sprinkler system throughout. (f) Removal of batteries unlawful. It shall be unlawful for any person to remove batteries or in any way render inoperable any smoke detector required to be installed by this section, except that this shall not apply to any building owner, manager or agent engaged in or causing periodic replacement of batteries or repair of required smoke detectors. (g) The requirement for installation of carbon monoxide detectors shall become effective April 1, 2005. (h) Violation. There shall be a minimum fine of $250.00 and a maximum of $750.00 for violations of this section.

(Code 1958, § 15-40.1; Ord. No. 28-86, § 1, 12-13-1986; Ord. No. 63-04, § 2, 3-9-2004; Ord. No. 3-05, 1-25-2005; Ord. No. 94-12, § 3.22, 12-11-2012)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.