Sec. 8-238. - Classification of wiring methods and materials.
The type of wiring used in buildings of various types of construction and occupancy shall be as follows: (a) In the installation of new electrical wiring and/or equipment, wire shall be installed in metal raceways of the type approved for the location. Exception No. 1. Type NM, NMC cable shall not be permitted to be used in air plenums or exposed areas. Exception No. 2. In any existing residential building not exceeding three (3) floors above grade or twelve (12) units, apartments or condominiums, Type NM, NMC cable of the grounded type or flexible metal conduit shall be permitted to be used in concealed locations. Type NM, NMC cable shall not be permitted to be used in air plenums or exposed areas. In multilevel one- and two-family dwellings an empty three-fourths-inch metal conduit shall be installed to the attic and crawl space. In a single or two-level one- and two-family dwelling with a basement an empty three-fourths-inch metal conduit shall be installed to the attic. In a single level one- and two-family dwelling without a basement an empty three-fourths-inch metal conduit shall be installed to the attic and crawl space. (b) Remodeling of existing structures: (1) In any building other than in fire-resistant buildings, the wiring shall be installed in metal raceways of the type approved for the location. Flexible metal conduit may be run or fished in air veins of concrete masonry block or tile walls where such walls are not subject to dampness; flexible metal conduit may be run or fished in existing walls or partitions where it is not possible to install conduit; flexible metal conduit may run in existing floors or ceilings where it is not possible to install conduit; flexible metal conduit shall never be used in buildings or parts of buildings being remodeled where it would be subject to mechanical injury; flexible metal conduit may be used in existing partitions where it is fished through the partition; and flexible metal conduit shall not be used between outlets in new partitions where the exterior finish of the partition has been removed for remodeling. (2) In a fire-resistant building(s) of the type listed above in Exception No. 1, and in residential buildings as listed in Exception No. 2, concealed wiring may be installed in metal rigid conduit, flexible metal conduit or nonmetallic sheathed cable of the grounded type where the conductor is concealed. Metal rigid conduit shall be required for all exposed wiring. (3) All abandoned electrical equipment and wiring must be removed from the building.
(Ord. No. 6554, § 8.3, 10-5-76; Ord. No. 7456, § 3(C), 1-6-81; Ord. No. 17754, § 4, 3-20-18)
Ask a question about Joliet law
Corpus searches the Joliet sections it holds and shows the ones that match, with their citations. Free, no sign-in.