Service entrance conductors and service switches (including underground services) shall have a current-carrying capacity sufficient to carry the load as determined by recommendations stated in the National Electric Code of the latest issue; however, in no case shall service entrance conductors or service switches have a rating less than one hundred (100) amperes for new installations or where electrical remodeling is being done. Conductor shall be sized in accordance with the 2014 NEC Table 310.16. A minimum of a 20 circuit service distributor panel is required.