For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-297 — Definitions

Code of Ordinances of the Village of Palatine, Illinois (Codified through Ordinance No. O-113-26, enacted October 12, 2026. (Supp. No. 2, Update 2)) · Palatine Code of Ordinances § 30-297

Corpus is an independent public-information project, not the official City of Palatine website. Stable reference: corpuslaw.us/code/7cfc9935-aab5-4296-b0a2-f5842b0b572d

Sec. 30-297. - Definitions.

The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: ASSE means American Society of Sanitary Engineering. Agency means state environmental protection agency. Air gap, in a water supply system, means the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank or plumbing fixture and the flood level rim of the receptacle. Approved means accepted or acceptable under an applicable specification stated or cited in this article or accepted as suitable for the proposed use. Auxiliary water system means any water source or system on or available to the premises other than the public water supply system. These auxiliary waters may include water from another purveyor's public water supply system; fire sprinkler connections or water from a source such as wells, lakes, ponds, or streams, or process fluids; or used water. These waters may be polluted or contaminated or objectionable or constitute a water source or system over which the water purveyor does not have control. Backflow means the flow of water or other liquids, mixtures, or substances into the distribution pipes of a potable water system from any source other than the intended source of the potable water supply. Backflow prevention device means any device, method, or type of construction intended to prevent backflow or back siphonage into a potable water system. All devices used for backflow prevention in the state must meet the standards of the Illinois Plumbing Code and the state environmental protection agency. Booster pump means a mechanical device used to increase domestic water pressure. CCCDI means cross connection control device inspector. Community water system (CWS) means a public water supply which is owned or operated by the village. Consumer or customer means the owner, official custodian or person in control of any premises supplied by or in any manner connected to a public water system. Consumer's water system means the service connection and any water system located on the customer's premises. A building plumbing system is considered to be a customer's water system with the exception of the water meter and its connections. Contamination means an impairment of the quality of the water by entrance of any substance to a degree which could create a health hazard. Cross connection means any physical connection or arrangement between two otherwise separate piping systems, one of which contains potable water and the other a substance of unknown or questionable safety or quality, whereby there may be a flow from one system into the other. Direct cross connection means a cross connection formed when a water system is physically joined to a source of unknown or unsafe substance. Indirect cross connection means a cross connection through which an unknown substance can be forced, drawn by a vacuum or otherwise introduced into a safe potable water system. Double check valve assembly or double check backflow prevention assembly means an assembly composed of single, independently acting check valves under ASSE Standard 1015. A double check valve assembly must include tight shutoff valves located at each end of the assembly and suitable connections for testing the water tightness of each check valve. Drainage means the routing of discharged used water from a reduced pressure principle backflow preventer, due to the proper operation of the device, pressure fluctuation, or malfunction of the device. Drainage shall be directed to a gravity flow sanitary drain, or an ejection system which is rated to be capable of meeting a full flow discharge from the device, or combination of devices which may be present. This shall apply to all domestic, irrigation, and fire prevention applications. Dual check valve or dual check backflow preventer means an assembly composed of single, independently acting check valves under ASSE Standard 1024 for containment. Health hazard means any condition, device or practice in a water system or its operation resulting in a real or potential danger to the health and well-being of consumers. The term "severe," as used to qualify "health hazard," means a hazard to the health of the user that could be expected to result in death or significant reduction in the quality of life. Inspection means a physical inspection to examine carefully and critically all materials, fixtures, piping and appurtenances, appliances and installations of a plumbing system for compliance with requirements of the Illinois Plumbing Code, 77 Ill. Adm. Code 890. Non-community water system (non-CWS) means a public water supply which is not a community water supply. Non-potable water means water not safe for drinking, personal, or culinary use as determined by the requirements of 35 Ill. Adm. Code 604. Plumbing means the actual installation, repair, maintenance, alteration or extension of a plumbing system by any person. Plumbing includes all piping, fixtures, appurtenances and appliances for a supply of water for all purposes, including, without limitation, lawn sprinkler systems, from the source of a private water supply on the premises or from the main in the street, alley or at the curb to, within and about any building where a person lives, works or assembles. Plumbing includes all piping, fixtures, appurtenances, and appliances for a building drain and a sanitary drainage and related ventilation system of any building where a person lives, works or assembles from the point of connection of such building drain to the building's sanitary sewer or private sewage disposal system for a distance of ten feet beyond the foundation walls. Pollution means the presence of any foreign substance (organic, inorganic, radiological, or biological) in water that tends to degrade its quality so as to constitute a hazard or impair the usefulness of the water. Potable water means water which meets the requirements of 35 Ill. Adm. Code 604 for drinking, culinary and domestic purposes. Potential cross connection means a fixture or appurtenance with threaded hose connection, tapered spout, or other connection which would facilitate extension of the water supply line beyond its designed termination point. Process fluids means any fluid or solution which may be chemically, biologically or otherwise contaminated or polluted in a form or concentration such as would constitute a health, pollutional, or system hazard if introduced into the public or a customer's potable water system. This includes, but is not limited to: (1) Polluted or contaminated waters; ..... (2) Process waters; ..... (3) Used waters originating from the public water supply system which may have deteriorated in sanitary quality; ..... (4) Cooling waters; ..... (5) Questionable or contaminated natural waters taken from wells, lakes, streams, or irrigation systems; ..... (6) Chemicals in solution or suspension; ..... (7) Oils, gases, acids, alkalis and other liquid and gaseous fluids used in industrial or other processes, or for firefighting purposes. ..... Public water supply (PWS) means all mains, pipes, water meters, and structures through which water is obtained and distributed to the public, including wells and well structures, intakes and cribs, pumping stations, treatment plants, reservoirs, storage tanks, water meters and appurtenances, collectively or severally, actually used or intended for use for the purpose of furnishing water for drinking or general domestic use and which serve at least 15 service connections or which regularly serve at least 25 persons at least 60 days per year. A public water supply is either a community water supply or a noncommunity water supply. Reduced pressure principle backflow prevention device or reduced pressure principle backflow prevention assembly means a device containing a minimum of two independently acting check valves together with an automatically operated pressure differential relief valve located between the two check valves and approved under ASSE Standard 1013. Service connection means the opening, including all fittings and appurtenances, at the water main through which water is supplied to the user. Survey means the collection of information pertaining to a customer's piping systems regarding the location of all connections to the public water supply system and must include the location, type and most recent inspection and testing date of all cross connection control devices and methods located within that customer's piping system. The survey must be in written form, and shall not be an actual plumbing inspection. System hazard means a condition through which an aesthetically objectionable or degrading material not dangerous to health may enter the public water supply system or a consumer's potable water system. Thermal expansion means a condition which occurs in a domestic water system, where a backflow preventer has been installed, creating a closed water system. Thermal expansion occurs when the cold water supplied to the hot water tank is heated. The expansion of the water caused by heat creates a need for the displacement of the expanded properties of the water. This is accomplished by installing a diaphragmed thermal expansion tank device, which displaces the expanded volume of water, keeping the internal piping system safe from extreme internal pressures. Used water means any water supplied by a public water supply system to a consumer's water system after it has been passed through the service connection and is no longer under the control of the water supply official custodian. Water purveyor means the owner or official custodian of a public water system.

(Code 1976, § 19-135; Ord. No. O-109-24, Exh. A(19-135), 11-18-2024)

Ask a question about Palatine law

Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.