Sec. 30-304. - Type of protection required.

(a) The type of protection required shall depend on the degree of hazard which exists as follows: ..... (1) An approved fixed proper air gap separation shall be installed where the public water supply system may be contaminated with substance that could cause a severe health hazard. ..... (2) An approved fixed proper air gap separation or an approved reduced pressure principle backflow prevention device shall be installed where the public water supply system may be contaminated with a substance that could cause a system or health hazard. ..... (3) An approved fixed proper air gap separation or an approved reduced pressure principle backflow prevention device shall be installed where the public water supply system may be polluted with substances that could cause a pollution hazard not dangerous to health. ..... (b) The type of protection required shall be an approved fixed proper air gap separation or an approved reduced pressure principle backflow prevention device. No double checks are permitted. ..... (c) Where a public water supply or an auxiliary water supply is used for a fire protection system, reduced pressure principle backflow preventers shall be installed on the fire safety system connected to the public water supply when: ..... (1) The fire safety system contains antifreeze, fire retardant, or other chemicals; ..... (2) Water is pumped into the fire safety system from another source; or ..... (3) Water flows into the fire safety system by gravity from a non-potable source; or ..... (4) There is a connection whereby water can be pumped into fire safety system from any other source; or ..... (5) There is a connection whereby another source can be connected to the fire safety system. .....

(Code 1976, § 19-142; Ord. No. O-109-24, Exh. A(19-142), 11-18-2024)

Ask a question about Palatine law

Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.