8.06. - Water distribution system.
(a) General. (1) No residential, commercial or industrial subdivision shall be approved unless it is served by the village's water supply system. (2) In the case of any buildings, be they residential, commercial or industrial, constructed prior to the adoption of this ordinance and served by a private well system, the following shall apply: a. As soon as a village water main is contiguous to and available to serve a building or an area on a private well system, the owner must properly abandon the private well system and connect to the village's public water supply system within one year of the availability of the public water supply system. b. All water supply systems which are installed in the public ways or easements serving a central system shall be deemed to be dedicated to the Village of Palatine upon acceptance of the subdivision. c. In all cases where a central water supply system is installed pursuant to the provisions of this section 8.05, said water supply system shall be deemed dedicated to the Village of Palatine upon acceptance of the subdivision. (b) Design. Water distribution mains shall be of adequate size and shall serve the entire development. (1) Design. Water mains shall be designed according to the "Standard Specifications for Water and Sewer Main Construction in Illinois" or according to the "Recommended Standards for Water Works." The more stringent requirements of either shall apply. (2) Installation. a. Said mains shall, in general, be installed in the street right-of-way, but in no case shall mains be installed within fifteen (15) feet of a building. b. All water mains shall be installed with a minimum depth of cover of five and one-half (5½) feet, measured from final grade to the top of the pipe. c. Mains shall be extended to the property line of the development along public rights-of-way and at any other location indicated by the village engineer. d. All excavation, backfilling, restoration of surfaces and all related work shall be completed in accordance with the supplement to these subdivision regulations. (3) Size. The minimum size shall be six (6) inches, internal diameter, in residential areas and eight (8) inches, internal diameter in all other areas. (4) Gridiron or looping of mains. a. Each six (6) inch water main shall be looped (except culs-de-sac or stubbed streets unless deemed necessary by the village engineer) so that runs between connections to six (6) inch or larger size mains shall not be greater than one block, not to exceed eighteen hundred (1,800) feet. b. Each eight (8) inch water main shall be looped so that runs between connections to mains eight (8) inches or larger shall not be greater than fourteen hundred (1,400) feet in a commercial area or eighteen hundred (1,800) feet in residential areas. c. Each ten (10) inch water main shall be looped so that runs between connections to mains ten (10) inches or larger shall not be greater than twenty-two hundred (2,200) feet. d. Each twelve (12) inch and larger water main shall be looped so that runs between connection to mains twelve (12) inches or larger shall not be greater than three thousand (3,000) feet. e. If the design engineer's report shows spacing greater than the above for the required residual pressure, that spacing shall supersede the above requirements. (c) Allowable materials. Allowable materials shall be those specified in the supplement to these subdivision regulations. (1) Valves. Valves shall be located on water mains so as to effectively isolate the sections from the system with minimum disruption. a. Valves shall be installed so that not over nine hundred (900) feet of main will be shut off at any given time. b. If a tee is installed, two (2) valves may be used. c. The design engineer shall, by diagrams and/or written reports, set forth his/her basis for location of water main valves. d. No more than thirty (30) single family dwelling units shall be without water with the shutting off of any three (3) valve locations. (2) Gate valves. Resilient seat gate valves are to be used on mains up to and including twelve (12) inches. Butterfly valves. Butterfly valves may be used on mains larger than twelve (12) inches. (3) Valves shall meet the requirements as specified in the supplement to these subdivision regulations. (4) Valve vaults. Valve vaults are required on all valves. (5) Valve boxes. Valve boxes shall be used on hydrant auxiliary valves only. a. Valve boxes shall have a base compatible with the size and type of valve to be operated and shall extend to finished grade ground level. b. Valve box covers shall be marked "water." (6) Thrust blocks. Thrust blocks are required at all valves, hydrants, tees and bends. a. Engineering drawings shall indicate the location of each concrete thrust block to be installed. b. Where undisturbed earth is not available or not likely to be available to back up pressure type concrete thrust blocks, the village engineer shall specify tie rods with or without anchor type concrete thrust blocks and submit design data for such specifications. (7) Air release valves. Air release valves shall be placed on the water main at high point as deemed necessary by the village engineer to serve as air vents preventing air locking of the water main. Air relief valves shall meet the requirements specified in the supplement to these subdivision regulations. (d) Fire hydrants. Whenever a water main is to be installed, the village fire prevention bureau must approve the hydrant spacing plan prior to commencement of work. (1) Design. a. Fire hydrants shall match the hydrants generally installed in the village's water system, and shall be furnished by a manufacturer considered standard by the village, and specified in the supplement to these subdivision regulations. b. Only breakaway hydrants shall be used. c. Each fire hydrant shall be the compression type with a five and one-fourth (5¼) inch minimum size main valve assembly, O-ring seals, two (2) two and one-half (2½) inch hose nozzles and a four and one-half (4½) inch pumper nozzle with National Standard threads, a National Standard operation nut, and a breakaway ground level flange, and conforming to the latest revised requirements of AWWA Specification C 502. d. Each hydrant shall be provided with a six (6) inch auxiliary gate valve and a two (2) foot length of six (6) inch pipe between the hydrant and valve. i. Two (2) three-fourth (¾) inch threaded steel rods with hex nuts shall be installed to tie the auxiliary gate valve to the water main and connecting tee. ii. Auxiliary valves shall be provided with valve boxes with covers marked "water." (2) Location. a. Fire hydrants shall be located no more than three hundred (300) feet from any point on the exterior of a building. b. If the location or configuration of the building requires it, then private fire hydrants shall be installed. c. The fire hydrant servicing a fire department connection (standpipe or sprinkler) shall be no more than one hundred and fifty (150) feet from that connection. d. Dead-end six (6) inch main extension serving hydrants in cul-de-sacs shall not be more than five hundred (500) feet long, except that six (6) inch extensions in commercial and industrial areas shall not exceed three hundred (300) feet. e. Where water transmission lines or off-site water lines are installed in existing rights-of-way (or in easements to existing rights-of-way), hydrants must be installed in at three hundred foot intervals. f. In other locations, six hundred (600) foot intervals are required with tees for future hydrants being provided within three hundred (300) feet of fire hydrants. (e) Fire protection system. (1) Fire flows. The design engineer shall show in a separate report that at several locations and at any other location that may be selected by the proposed water main system, together with that proposed in the master plan for the village, will supply the fire flows required below in excess of domestic consumption demands, using a "C" factor of one hundred (100) for cast iron or ductile iron, ignoring fittings, and with a minimum residual pressure of twenty (20) psi. a. Residence: i. Dwellings, detached and semi-detached—one thousand to one thousand five hundred (1,000—1,500) GPM. ii. Dwellings, attached (townhouses); each unit separated by an approved firewall—three thousand to four thousand (3,000—4,000) GPM. b. Business: i. Business and office uses—two thousand five hundred to three thousand (2,500—3,000) GPM. ii. Commercial and mercantile buildings, including warehouses—three thousand to six thousand (3,000—6,000) GPM. c. Manufacturing: Three thousand to six thousand (3,000—6,000) GPM. d. Institutional: Three thousand (3,000) GPM. (2) Private booster pumps for fire protection. a. No pump shall be installed without specific approval of the village fire prevention bureau. b. Pumps shall be designed in conjunction with an inside standpipe system as to not require an excessive amount of water to be drawn from the village water supply. c. If calculations show that the resulting residual pressure in the public water main at the point of connection to the private system is less than twenty-five (25) psi., then pressure tanks or gravity tanks must be provided with the capacity to supply not less than two hundred and fifty (250) gallons per minute in buildings for one standpipe and not less than five hundred (500) gallons per minute in buildings where two (2) or more standpipes are required, for a period of at least thirty (30) minutes. d. The pressure at the base outlet shall not be less than fifty (50) pounds per square inch. (f) Water services. (1) The plans, except for residential developments with individual services for each unit, shall show the calculated static water pressure at the lowest and highest ground elevations on the site. Calculations shall be presented showing that the proposed water service are of a large enough size to supply an adequate flow of water at the outlet of the meter, assuming the service is "fairly rough pipe," as specified in the "Illinois State Plumbing Codes," current edition. (2) The developer shall provide and have installed service saddles, corporation stops, curb stops, service boxes and water service tubing as required in section 19.20 of the municipal code. (3) Water service lines shall be laid at a minimum depth of five (5) feet below the finished grade ground level. (4) All service line shutoffs shall be located in parkways, or in appropriate easement areas. (5) A "W" shall be marked in the curbing when poured opposite to the water service as a permanent record of location.
Ask a question about Palatine law
Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.