§ 8.07 — Sanitary sewer system

Code of Ordinances of the Village of Palatine, Illinois (Codified through Ordinance No. O-113-26, enacted October 12, 2026. (Supp. No. 2, Update 2)) · Palatine Code of Ordinances, App. B, art. VIII, § 8.07

Corpus is an independent public-information project, not the official City of Palatine website. Stable reference: corpuslaw.us/code/fee8a4f1-234d-4beb-8b3e-1745f586fd70

8.07. - Sanitary sewer system.

(a) General. (1) Except as otherwise provided herein, no residential, commercial or industrial subdivision or development shall be approved unless it is served by sanitary sewers connected to the village's sewer system. (2) In the case of any existing buildings, be they residential, commercial or industrial, constructed prior to the adoption of this appendix and served by a septic system, the building can remain on the septic system so long as it is operating properly. If the system fails or requires repairs, renovations or maintenance beyond normal pumping of the tank, and a public sanitary sewer main is available to the property on which the building is located, in accordance with Section 905.20(e) of the Private Sewage Disposal Code of the state then said owner or owners must properly abandon the septic system and connect to the village's public sanitary sewer system. (3) All sanitary sewer mains which are installed in the public ways or in easements serving a central system shall be deemed to be dedicated to the village upon the acceptance of the public improvements within the subdivision by the village. (b) Design. Sewer mains shall be of adequate size and shall serve the entire development. (1) General requirements. a. Sewer mains shall be designed according to the latest edition of the "Standard Specifications for Water and Sewer Main Construction in Illinois" or according to "Recommended Standards for Sewage Works." The more stringent requirements of either shall apply. b. Before commencing the sewer layout, the developer shall confer with the village to determine the required size and grades for any trunk sewers traversing and subdivision to fit the village's available capacities of off-site downstream existing facilities to the Metropolitan Water Reclamation District of Greater Chicago interceptor together with the estimated increment of flow caused by the subdivision or development on such facilities. Construction required to accommodate said increment shall be submitted as part of engineering plans. c. All sanitary sewers shall be constructed in accordance with the provisions of Division II and Division III of the latest edition of the Standard Specifications for Water and Sewer Main Construction in Illinois and Article 7 of the Cook County Watershed Management Ordinance, as modified and/or more specifically defined in these paragraphs and sections. In case of conflict, the provisions of the following paragraphs shall apply. (2) Installation. a. Said mains shall, in general, be installed in the street right-of-way or in an easement adjacent thereto. In no case shall mains be installed within ten (10) feet of a building. b. Sanitary sewers shall be extended to the edge of the development along public rights-of-way and at other points indicated by the village engineer. (3) Size. The minimum size of mains shall be eight (8) inch internal diameter. (4) Sewer services. Sanitary sewer service laterals of a minimum of six (6) inch internal diameter shall be provided for each lot, parcel or tract prior to the construction of street pavements. Services shall extend to the property line. a. Service connection shall consist of a one-eighth (⅛) sewer pipe bend set in the bell of the wye or tee and the necessary lengths of the pipe. b. Service sewers shall have a minimum cover of thirty (30) inches on private property, and forty-eight (48) inches in public rights-of-way. c. Two (2) or more structures are not permitted to use a joint building service sewer. d. A minimum velocity of two and one-half (2.5) Ft/Sec. shall be maintained. (5) Sewer alignment. Alignment shall follow the general layout of the street. a. Curvilinear sewer alignment for sewers twenty-four (24) inches in diameter or less shall be limited to curved street areas and only simple curves shall be used. b. The minimum radius shall be no less than three hundred (300) feet provided that the allowable deflection of the pipe joints is not exceeded. c. A minimum velocity of two (2.00) ft/sec. shall be maintained in curvilinear sewers and the hydraulics of the curvilinear alignment shall be taken into account and if necessary minimum slopes indicated in section 8.07(8) may have to be increased. (6) Manholes. Manholes shall be installed not more than four hundred (400) feet apart for sewers fifteen (15) inches in diameter or less, and five hundred (500) feet for sewers eighteen (18) inches to thirty (30) inches in diameter. a. Manhole diameter. Manhole diameter shall be four (4) feet for sewer diameter twenty-four (24) inches, and five (5) feet for sewer diameter twenty-seven (27) inches to forty-two (42) inches, inclusive. b. Inspection manholes. An inspection manhole having a minimum diameter of forty-eight (48) inches is required for all commercial and industrial buildings. i. The manhole shall be constructed on the building service sewer before it connects to the sewer main, and preferably shall not be closer than five (5) feet to the building. ii. There shall be no flow into the inspection except the flow from the building or buildings for which the inspection manhole is intended. c. Exterior drop pipes. An exterior drop pipe should be provided for a sewer entering a manhole at an elevation of twenty-four (24) inches or more above the manhole invert. i. The minimum diameter of the drop pipe shall be forty-eight (48) inches. ii. The diameter of the drop pipe shall preferably be larger than, or the same diameter as, the entering sewer and in no case shall be smaller than two (2) nominal diameters. iii. For sewer mains thirty-six (36) inches or larger, the requirements for a drop pipe do not apply if the spring line of the incoming pipe is at or below the spring line of the main sewer. (7) Lift stations. If a lift station is part of the engineering design, it shall be shown in the plan elevation and the specifications for such lift station shall be submitted with engineering plans. a. Lift stations shall be of the dry well or wet well type, and shall conform in all respects to the standards established by the State of Illinois Environmental Protection Agency and the Metropolitan Water Reclamation District of Greater Chicago. b. A separate source of power shall be furnished to each sewerage lift station. This shall be from another electrical source or provided by a separately powered engine. c. Engine, enclosure and mounting shall be subject to approval by the village engineer. d. The lift station shall be connected to the village's SCADA system and shall allow for remote operation of the lift station from the village's control room and shall provide alarms of various system failures and relay such operational information as deemed necessary by the village engineer. e. Lift stations and force mains are not desirable nor recommended and shall be resorted to only after all engineering studies have been exhausted. (8) Slopes. Minimum and maximum slopes are tabulated below. The slopes are those that produce minimum and maximum velocities of two (2.0) ft/sec. and fifteen (15) ft/sec. based on Kutter's formula with n=0.013 and the pipe flowing full, as provided in the rules and regulations of the Illinois Sanitary Water Board. Sewer Size (inches) | Minimum Slope Percent | Maximum Slope Percent 6 | 0.63 | 33.0 8 | 0.40 | 22.0 10 | 0.28 | 15.0 12 | 0.22 | 11.0 14 | 0.17 | 9.0 15 | 0.15 | 8.3 16 | 0.14 | 7.8 18 | 0.12 | 6.5 21 | 0.10 | 5.1 24 | 0.08 | 4.2 (c) Allowable materials. Allowable materials shall be those specified in the supplement to these subdivision regulations. (d) Construction requirements. General requirements shall be those specified in the supplement to these subdivision regulations. (e) Wyes or tees. Wyes or tees for existing or future lateral connections shall be inserted in the sewer at the appropriate location as required by the village engineer, and shall be constructed so as to be an integral part of the main sewer pipe. (f) Inspection and tests. Inspections and tests shall be those specified in the supplement to these subdivision regulations.

(Ord. No. O-134-14, § 1, 10-20-2014)

Ask a question about Palatine law

Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.