§ 153.161 — Surface water drainage
Code of Ordinances, City of Springfield, Illinois (Supp. No. 82: codified through Ordinance No. 146-04-26, enacted April 7, 2026) · Springfield, Ill., City Code § 153.161
Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/c3f04a9f-8dce-4470-9b55-07674c0492a7
§ 153.161. - Surface water drainage.
(a) All subdivisions shall be developed with adequate surface drainage. Surface water drainage improvements shall consist of storm sewers and/or open channels, inlets, catch basins and manholes designed and constructed to conform with standards established by the city engineer and shall adequately drain the area being developed including drainage from other areas which naturally drain through the area being developed. Storm water quality will also be considered when reviewing drainage plans. (b) If the surface water drainage will be changed, reasonable provision shall be made for the collection and diversion of such surface waters into public areas or drains which the subdivider has a right to use. Such provisions shall be planned for in accordance with generally accepted engineering practices to reduce the likelihood of damage to other properties because of the construction of the subdivision. (c) If, as the result of subdivision development, surface water is deposited in existing roadside ditches in quantities exceeding their capacity, the developer shall improve the ditches and replace culverts as needed to handle the flow. (d) (Specific information for required basin analysis is to be obtained form the city engineer.) Unless engineering evidence is presented to the city engineer warranting exceptions, storm sewers shall be designed and constructed to meet the following criteria: (1) All improvements shall be designed to handle runoff from a storm having a five-year frequency. Storm sewer conduit drains that discharge to open channels shall terminate with suitable outlet structures to control soil erosion and to prevent progressive failure of the conduit in an upstream direction. (2) Inlets and/or catch basins shall be spaced so that water will not flow overland more than 500 feet and shall be located so that in no case will water be required to flow across a street or be retained outside the center ten feet of drainage-utility easement. Inlets covered by a metal grate shall have a grate of a type that will not be hazardous to a bicyclist. (3) Storm sewer slopes shall be such that a minimum velocity of 2.5 feet per second is maintained when the pipe is flowing full without surcharge. In cases where it is impractical to obtain the above minimum velocity, modification shall be subject to approval by the city engineer. (4) Manholes on storm sewers shall be located at the beginning and end of all sewer runs, and at changes in slope, size and direction. The distance between manholes shall not exceed 500 feet except in locations where a greater distance will make the manholes more accessible. This greater distance shall be subject to the approval of the city engineer. (5) Manholes shall be constructed of concrete or masonry units having an internal diameter of not less than four feet, fitted with cast iron frames and covers and either cast iron or plastic steps. Manholes shall be constructed with precast bottoms and a lock or other approved connections. (6) Joints for storm sewer conduit shall be mortar joints or bituminous joints complying with paragraph 30.3.2 B or paragraph 30.3.2 C respectively, as specified in the latest revised edition of the Standard Specifications for Water and Sewer Main Construction in Illinois. (7) It shall be the responsibility of the subdivider to provide grade control for rear lot drainage to each lot owner. Grade control shall consist of a minimum of permanent monuments set at grade in the flowlines of the swales at intervals not exceeding 200 feet. The monuments should consist of a minimum of six-inch diameter concrete thirty-six inches deep, with an iron rod embedded in the concrete (or other design approved by the city engineer). Paved ditches and/or other private improvements may be required in areas with high water tables, low slopes, and/or erosion problems. It shall be the lot owner's responsibility to maintain the drainage course and to keep it free from features that restrict natural drainage. Storm water detention shall be required where determined to be necessary by the city engineer. Detention should be designed in accordance with the Illinois Department of Transportation Drainage Manual, or other methodology approved by the city engineer. (8) Limited temporary surface storage of runoff from storms exceeding the design frequency may be permitted, subject to the approval of the city engineer.
(Ord. No. 804-10-93, § 1(Exh. A), 10-19-93)
Ask a question about Springfield law
Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.