For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 153.163 — Sewage disposal

Code of Ordinances, City of Springfield, Illinois (Supp. No. 82: codified through Ordinance No. 146-04-26, enacted April 7, 2026) · Springfield, Ill., City Code § 153.163

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/ace28796-23a1-4a2b-a605-09a89a0f04c6

§ 153.163. - Sewage disposal.

(a) Sanitary sewers. When a subdivision is located within the service area of a public sanitary sewerage system, sanitary sewers shall be constructed throughout the entire subdivision in such a manner as to serve adequately each building lot. (1) Public sanitary sewers shall be located in the north or west boulevard (between curb and sidewalk) within the street right-of-way or in a 15 foot easement behind the sidewalk within the house setback area. Parallel sewer lines along the street may be used. Sanitary sewers shall not be located in the rear yard. (2) Under no circumstances shall the entrance of storm water or ground water to the sanitary sewers be permitted. (3) When a private sewage disposal system is proposed in the City of Springfield corporate limits, it must follow the procedures in Chapter 51 of the City Code. All sanitary sewer connections and disposal systems shall comply with the ordinances of the City of Springfield, the Springfield Metro Sanitary District and the requirements of the Illinois Environmental Protection Agency. Sizes and slopes should be determined based on projected flows. Sewage systems must also meet all requirements of the Springfield Sewer Use Ordinance. (4) Construction features and details for sanitary sewers and appurtenances shall comply with the latest revised edition of the Standard Specifications for Water and Sewer Main Construction in Illinois. (5) Manholes on sanitary sewers shall be located at the beginning and end of all sewer runs, and at changes in slope, size and direction. The distance between manholes shall not exceed 500 feet. (6) Manholes shall be constructed of concrete or masonry units having an internal diameter of not less than four feet, fitted with cast iron frames and covers and either cast iron or plastic steps. Manholes shall be constructed with precast bottoms and a lock or other approved pipe connections. (7) Sewer service laterals from the main sewer to the front property line of each lot in the subdivision shall have an internal diameter of not less than six inches for a multiple family structure and not less than four inches for a single-family or duplex structure. Where adequate grade can be maintained, sewer service laterals shall be a minimum of five feet deep at the right-of-way line. Each service lateral shall be adequately plugged with a suitable disc or stopper at the end of the line to make the joint formed completely water tight. Service lateral construction shall be equivalent to the requirements for main collecting sanitary sewers and properly marked so it can be located from the surface. The lowest sanitary sewer outlet elevation from a residence shall be according to the standards of the Springfield Metro Sanitary District. (8) Upon completion of the sewer construction, an air test, infiltration test or exfiltration test, as required by the district engineer of the Springfield Metro Sanitary District, shall be conducted on the entire sewer system before any building is allowed to connect to the system. The test shall be conducted under supervision of a registered professional engineer. The engineer shall furnish a certified copy of the test results to the city engineer and the district engineer of the Springfield Metro Sanitary District before connection of service lines. (b) Private sewage disposal systems. (1) Percolation tests are required for representative areas for sketch plans and for every lot in final plats. Percolation tests shall be conducted in accordance with state law. Testing shall be supervised and approved by the Sangamon County Department of Public Health. (2) When a private sanitary sewerage system is allowed (see section 153.112(a)(1)), individual sanitary disposal systems shall be installed to service individual dwelling units according to conditions set forth in section 153.112. These sanitary disposal systems shall be installed in accordance with the latest revised edition of the Illinois Private Sewage Disposal Licensing Act and private sewage disposal code promulgated by the Illinois Department of Public Health and the applicable ordinances of the City of Springfield and Sangamon County. Sufficient area shall be provided to accommodate two seepage fields.

(Ord. No. 804-10-93, § 1(Exh. A), 10-19-93; Ord. No. 264-07-12, § 1(Exh. A), 7-17-12)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.