§ 20.04.020 — Dimensional standards
Code of Ordinances, City of Bloomington, Indiana (Supp. No. 51, Update 1: codified through Ordinance No. 2026-15, passed July 17, 2026) · Bloomington Municipal Code § 20.04.020
Corpus is an independent public-information project, not the official City of Bloomington website. Stable reference: corpuslaw.us/code/888105ae-019b-4b88-a1a7-8a5651d2383b
20.04.020 - Dimensional standards.
(a) Purpose. This section is intended to provide dimensional standards and uniform methods of measurement for interpretation and enforcement of the lot and building standards in this UDO. (b) Applicability. Compliance with this Section 20.04.020 (Dimensional Standards) shall be required pursuant to Section 20.04.010 (Applicability). (c) General Dimensional Standards. The following tables, Table 04-2 through Table 04-5, establishes the dimensional standards for Residential, Mixed-Use, and other zoning districts contained in Chapter 20.02 (Zoning Districts). In case of a conflict between the dimensions shown in this Section 20.04.020 and the dimensions shown for individual districts in Chapter 20.02 (Zoning Districts), the provisions of this Section 20.04.020 shall govern. (1) Residential Zoning Districts. Dimensional standards for Residential zoning districts are shown in Table 04-2 (Residential District Dimensional Standards). (2) Mixed-Use Zoning Districts. Dimensional standards for Mixed-Use zoning districts are shown in Table 04-3 (Mixed-Use District Dimensional Standards). (3) Downtown Character Overlays. Dimensional standards for the Downtown Character Overlays are shown in Table 04-4 (Downtown Character Overlay Dimensional Standards). (4) Nonresidential Zoning Districts. Dimensional standards for Nonresidential zoning districts are shown in Table 04-5 (Nonresidential District Dimensional Standards). _____ Table 04-2. Residential District Dimensional Standards Dimensional Standards | R1 | R2 | R3 | R4 | RM [1] | RH [1] | RMH [1] Lot Dimensions (minimum, only for lots created after the effective date) | Entire Development | Dwelling Site Lot area | sq. ft. | 20,000 [2] | 7,200 [2] | 5,000 [2] | 4,000 [2] | 5,000 | 5,000 | 43,560 | 3,000 acres | 0.459 [2] | 0.165 [2] | 0.115 [2] | 0.092 [2] | 0.115 | 0.115 | 1.00 | 0.069 Lot width | 100 feet [2] | 60 feet [2] | 50 feet [2] | 35 feet [2] | 50 feet | 50 feet | 200 feet | 40 feet Building Setbacks (minimum) | Entire Development | Dwelling Site Front build-to line | None | None | 15 feet [3] | None | None | None | None | None Front | 15 feet | 15 feet [3] | None | 15 feet [3] | 15 feet | 15 feet | 25 feet | 10 feet Attached front-loading garage or carport | 25 feet [4] | 25 feet [4] | 10 feet behind the primary structure's front building wall | 25 feet [4] | None | None Side | First floor: 8 feet Each story above the ground floor: 10 feet [2] | First floor: 8 feet Each story above the ground floor: 10 feet [2] [5] [7] | First floor: 6 feet Each story above the ground floor: 10 feet [2] [5] [7] | 5 feet [2] [7] | 10 feet [6] | 10 feet [6] | 20 feet | Primary structure: 7 feet Accessory structure: 2 feet Rear | 25 feet [2] | 25 feet [2] [7] | 25 feet [2] [7] | 25 feet [2] [7] | 15 feet [6] | 15 feet [6] | 20 feet Other Standards | Entire Development | Dwelling Site Front parking setback (minimum) | None | None | None | None | 20 feet behind the primary structure's front building wall | None | None Side parking setback (minimum) | None | None | None | None | 8 feet | 8 feet | None | None Rear parking setback (minimum) | None | None | None | None | 8 feet | 8 feet | None | None Impervious surface coverage (maximum) | 30% | 40% | 45% | 50% | 60% | 65% | None | 65% Landscape area (minimum) | None | None | None | None | 40% | 35% | None | None Primary structure height (maximum) | 40 feet | 40 feet | 35 feet | 40 feet | 3 stories, not to exceed 40 feet [2] [6] | 5 stories, not to exceed 63 feet [2] [6] | None | 20 feet Accessory structure height (maximum) | 20 feet | 20 feet | 20 feet | 20 feet | 20 feet | 20 feet | None | 20 feet sq. ft. = square feet Notes: [1] Any single-family, duplex, triplex, or fourplex development shall be subject to the R4 residential lot standards, except that the front building setback shall be determined by the standards of the base's zoning district. [2] See Section 20.04.110 (Incentives) for alternative standards. [3] Or the median front setback of abutting residential structures, whichever is less. [4] Or equal to the setback of the primary structure, whichever is greater. [5] Legally established lots of record that are less than the minimum lot width may reduce the required setback up to two feet. [6] Buildings abutting a property in the R1, R2, R3, or R4 zoning district shall comply with the standards in Section 20.04.070(d)(5) (Neighborhood Transition Standards). [7] Side primary building setbacks shall be reduced by two feet if adjacent to a platted alley. Rear primary building setbacks shall be reduced by ten feet if adjacent to a platted alley. _____ Table 04-3. Mixed-Use District Dimensional Standards Dimensional Standards | MS [7] | MN | MM | MC | ME | MI | MD | MH Lot Dimensions (minimum, only for lots created after the effective date) Lot area | sq. ft. | 5,000 | 5,000 | 5,000 | 5,000 | 5,000 | 5,000 | See Table 04-4 | 10,890 acres | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 | 0.115 | 0.25 Lot width | 50 feet | 50 feet | 50 feet | 50 feet | 50 feet | 50 feet | 65 feet Building Setbacks (minimum) Front build-to range | None | 15 to 25 feet | 15 to 25 feet | None | None | None | See Table 04-4 | None Front building facade at build-to range (minimum) | None | 70% | 70% | None | None | None | None Front | 15 feet | (see above) | (see above) | 15 feet | 15 feet | 15 feet | 25 feet Side [1][6] | 15 feet | 7 feet | 7 feet | 7 feet | 10 feet | 10 feet | 10 feet Rear [1][6] | 10 feet Other Standards Front parking setback (minimum) | 20 feet behind the primary structure's front building wall | See Table 04-4 | 20 feet behind the primary structure's front building wall Side parking setback (minimum) | 8 feet | 8 feet | 8 feet | 8 feet | 8 feet | 8 feet | 8 feet Rear parking setback (minimum) | 8 feet | 8 feet | 8 feet | 8 feet | 8 feet | 8 feet | 8 feet Impervious surface coverage (maximum)[4] | 70% | 60% | 60% | 60% | 70% | 60% | 60% Landscape area (minimum)[5] | 30% | 40% | 40% | 40% | 30% | 40% | 40% Area of any individual commercial tenant (maximum) | None | 5,000 sq. ft. gross floor area | None | None | None | None | None Primary structure height (maximum) [1] [2] [3] | 6 stories, not to exceed 75 feet | 3 stories, not to exceed 40 feet | 4 stories, not to exceed 50 feet | 4 stories, not to exceed 50 feet | 5 stories, not to exceed 63 feet | 4 stories, not to exceed 50 feet | 3 stories, not to exceed 40 feet Accessory structure height (maximum) | 20 feet | 20 feet | 30 feet | 30 feet | 30 feet | 30 feet | 25 feet sq. ft. = square feet Notes: [1] Buildings abutting a property in the R1, R2, R3, or R4 zoning district shall comply with the standards in Section 20.04.070(d)(5) (Neighborhood Transition Standards). [2] Where a nonresidential use is proposed on the ground floor, the minimum floor to ceiling height shall be twelve feet. [3] See Section 20.04.110 (Incentives) for alternative standards. [4] Lots zoned MM north of 1st Street, south of 2nd Street east of Maple Street (extending south of 2nd Street to 1st Street) and west of Morton Street shall have an impervious surface coverage maximum of eighty-five percent. [5] Lots zoned MM north of 1st Street, east of Maple Street (extending south of 2nd Street to 1st Street) and west of Morton Street shall have a minimum landscape area of fifteen percent. [6] Lots zoned MM north of 1st Street south of 2nd Street east of Maple Street (extending south of 2nd Street to 1st Street), and west of Morton Street shall have minimum side and rear building setbacks of zero feet. [7] Any single-family, duplex, triplex, or fourplex development shall be subject to the R4 residential lot standards, except that the front building setback shall be determined by the standards of the base's zoning district. _____ Table 04-4. Downtown Character Overlay Dimensional Standards Dimensional Standards | MD-CS | MD-DC | MD-UV | MD-DE | MD-DG | MD-ST Lot Dimensions (minimum) Lot area | None | None | None | None | None | None Lot width | None | None | None | None | None | None Building Setbacks Front build-to range | 0 to 5 feet | 0 to 5 feet | 0 to 15 feet | 0 to 15 feet | 0 to 15 feet | None Front building facade at build-to range (minimum) | 90% | 70% | 70% | 70% | 70% | None Front (maximum) | None | None | None | None | None | 15 feet Adjacent to B-line (minimum) | None | 10 feet | None | None | None | 15 feet Side (minimum) [1] | None | None | None | 7 feet | 5 feet | 5 feet Rear (minimum) [1] | None | None | None | 10 feet | 5 feet | 5 feet Other Standards Front parking setback (minimum) | 20 feet behind the primary structure's front building wall Side and rear parking setback (minimum) | Requirements set per Section 20.04.080(h)(1)(A)(ii) Impervious surface coverage (maximum) | 100% | 100% | General and Restaurant Row: 85% Kirkwood Corridor: 100% | 75% | 75% | 85% Landscape area (minimum) | None | None | General and Restaurant Row: 15% Kirkwood Corridor: None | 25% | 25% | 15% Primary structure height (maximum) [1] [2] [3] [4] | 3 stories, not to exceed 40 feet | 4 stories, not to exceed 50 feet | General and Kirkwood Corridor: 3 stories, not to exceed 40 feet Restaurant Row: 3 stories, not to exceed 35 feet | 3 stories, not to exceed 40 feet | 3 stories, not to exceed 40 feet | 4 stories, not to exceed 50 feet Primary structure height (minimum) | 25 feet | 35 feet | General and Kirkwood Corridor: 25 feet Restaurant Row: 20 feet | 20 feet | 25 feet | 25 feet Accessory structure height (maximum) | 25 feet | 25 feet | 25 feet | 25 feet | 30 feet | 30 feet sq. ft. = square feet Notes: [1] Buildings abutting a property in the R1, R2, R3, or R4 zoning district shall comply with the standards in Section 20.04.070(d)(5) (Neighborhood Transition Standards). [2] Where a nonresidential use is proposed on the ground floor, the minimum floor to ceiling height shall be twelve feet. [3] See Section 20.04.110 (Incentives) for alternative standards. Additional height incentives shall not be available for student housing or dormitories. [4] Buildings that include one or more dwelling units that meet the definition of "Student Housing or Dormitory" shall be subject to the maximum building heights established in Section 20.03.030(b)(13) (Student Housing or Dormitory). _____ Table 04-5. Nonresidential District Dimensional Standards Dimensional Standards | EM | PO Lot Dimensions (minimum, only for lots created after the effective date) Lot area | None | None Lot width | 100 feet | None Building Setbacks (minimum) Front | 25 feet | 15 feet Side | 20 feet [1] | 5 feet Rear | 20 feet [1] | 5 feet Other Standards Front parking setback (minimum) | 20 feet behind the primary structure's front building wall | 15 feet Impervious surface coverage (maximum) | 70% | None Landscape area (minimum) | 30% | None Primary structure height (maximum) | 4 stories, not to exceed 50 feet [1] | 20 feet Accessory structure height (maximum) | 35 feet | 20 feet sq. ft. = square feet Notes: [1] When adjacent to the R1, R2, R3, or R4 zoning district, the minimum setback shall be increased by one foot for each foot of building height over thirty feet. _____ (d) Lot and Space Requirements. (1) Minimum Lot Dimensions. No space that is needed to meet the width, setback, area, open space, impervious surface coverage, parking, landscaping, or other requirements of this UDO for a lot or building may be sold, leased, or subdivided away from such lot or building. All lots affected by a proposed subdivision shall meet the standards of this UDO. (2) Number of Primary Buildings or Uses per Lot. (A) Except for projects approved as cottage development pursuant to Section 20.03.030(b)(7) (Dwelling, Cottage Development), only one principal building for single-family, duplex, triplex, or fourplex uses, with permitted accessory buildings, may be located on a lot or parcel. Every dwelling shall have legal means of access to a right-of-way. (B) Where a lot or parcel is used for multifamily, mixed-use, commercial, or industrial purposes, more than one primary building may be located upon the lot when such buildings conform to all requirements of this UDO applicable to the uses and district. (C) No lot shall be divided to contain more dwelling units than are permitted by the regulations of the zoning district in which they are located. (e) Setbacks. (1) Measurement. (A) Setbacks referred to in this UDO shall be measured as stated in Chapter 20.07 (Definitions), under the term "setback" and "build-to range." (B) For private streets, setbacks shall be measured from the edge of the curb, easement, or right-of-way, whichever distance is greater. (C) Where existing right-of-way is wider than that proposed on the Transportation Plan, the setback shall be measured from the existing right-of-way. (D) For lots of record with no street frontage, a minimum building setback of ten feet is required from the property line where access is gained. All other lot lines shall be considered side lot lines for the purposes of setbacks. (E) The minimum front building facade at the build-to range percentage shall be determined by calculating the width of the principal building that is within the build-to range divided by the total width of the lot at the street frontage. (2) Single-Family Attached and Multifamily Dwellings. (A) Multifamily dwellings on one lot shall be construed as one structure for purpose of measuring setbacks. (B) For purposes of setback calculations for side-by-side single-family attached or multifamily dwellings, only those dwelling units that do not share a common wall with an adjacent unit (end units) shall observe the required side setback for the district. (3) Exceptions to Setback Requirements. (A) The setback exceptions established in Table 04-6 shall not authorize the encroachment of any development across property lines or into a public right-of-way. (B) Every part of a required setback shall be unobstructed from ground level to the sky, except as follows: _____ Table 04-6. Authorized Exceptions to Setback Requirements Type of Exception | Extent of Exception Air conditioners (ground) | Up to 5 feet if screened by a fence, wall, or appropriate landscaping. Air conditioners (window) | Up to 30 inches. Architectural features | Up to 18 inches. Awning, balconies, canopies, patios, and attached exterior stairs | Up to 6 feet. Bay windows, chimneys, eaves | Up to 3 feet. Decks | Up to 6 feet into the side or rear setback provided that no deck is closer than 2 feet to a side property line. Fire escapes | Up to 6 feet into side and rear setbacks. Front entry | For existing and new primary structures in the R1, R2, R3, and R4 zoning districts, an entry or covered front addition a maximum of 6 feet deep and with a width not to exceed one-third the width of the primary facade of the structure is permitted to encroach into the front building setback, however a minimum 4' setback is required from the front property line. Accessible ramps | Exempt from all setback requirements. Satellite dishes | Up to 5 feet into the front setback and no closer than one foot to the side and rear property lines. Detached garages or carports | Where a rear alleyway provides access to a detached garage or carport, the setback from the property line that runs parallel to the alleyway to the detached garage or carport may be reduced to 3 feet. Additions to existing primary structures | For single-family, duplex, and triplex structures, additions to the first floor footprint of existing primary structures may use existing side or rear setbacks already established on the lot, provided that the gross floor area of the existing structure is not increased by more than 50 percent. In no case shall the setback be less than 10 feet (rear) or 4 feet (side). Vertical additions to existing primary structures may utlize existing front setbacks provided that the existing structure is equal to, or has a greater front setback than, the median front setback of abutting residential structures. Additions to structures that don't meet build-to ranges | Additions may be added that move the building closer to build-to range compliance, even if compliance is not achieved. DU = dwelling unit _____ (C) Where this UDO establishes a maximum setback from the front property line, that maximum setback may be increased by up to five feet to accommodate access required by the Americans with Disabilities Act, utility or access easements, or to prevent encroachment of building projections over the public right-of-way. (D) For parking and building setback purposes, Interstate 69 is not considered a front. (4) Through Lots. On a through lot, the Planning and Transportation Director shall determine which lot line shall be deemed the front lot line based on the existing and/or proposed building orientation of surrounding lots. Through lots adjacent to an arterial street shall comply with the standards established in Section 20.05.050(j)(7)(A)iii. (Buffer). (f) Building Height. (1) Measurement. Maximum building heights are expressed in both overall dimension and the number of stories, where applicable. (A) Stories. Story height is measured between the floor of a story to the floor of the story above it. For single-story buildings and the uppermost story of a multistory building, the measurement shall be from the floor of the story to the ceiling. (B) Overall Dimension. The height of buildings shall be measured as the vertical distance from the average finished grade surface of the building, structure, or wall exposed above the ground surface to the highest point of the roof, parapet wall, or uppermost part. [image omitted; see the official code] Figure 50: Building Height (2) Exceptions to Height Requirements. No building or structure or part of a building or structure shall exceed the maximum building height within any zoning district unless authorized in Table 04-7, or elsewhere in this UDO. _____ Table 04-7. Authorized Exceptions to Height Requirements Type of Exception | Extent of Exception Place of worship elements | Steeples, bell towers, and similar features may exceed the maximum height of the applicable zoning district by no more than 25 percent of the applicable maximum height. Chimneys and other ornamental architectural features | Chimneys and other ornamental architectural features may extend 10 feet above the roof's highest point. Solar Collector | In the R1, R2, R3, and R4 zoning districts, accessory building-mounted solar collectors may exceed the maximum building height requirement by a maximum of 36 inches. For all other zoning districts, accessory building-mounted solar collectors may exceed the maximum building height requirement by a maximum five feet. Water towers and quarry derricks | Water towers and quarry derricks are allowed up to a height of 150 feet. Mechanical equipment and elevator bulkheads | Roof-mounted mechanical equipment including, but not limited to, utility boxes, telecommunication devices, cables, conduits, vents, chillers and fans, may extend up to 10 feet above the roof's highest point. In such cases, roof-mounted equipment shall comply with the requirements of Section 20.04.080(m)(1) (Roof-Mounted Mechanical Equipment). Communication facilities | Communication facilities are exempt from height restrictions, subject to the limitations of Section 20.03.030(f)(1) (Communication Facility). _____ (g) Building Floor Plate. (1) The area of the lot covered by the primary building shall be included in the calculation of building floor plate in all districts. (2) The area of a lot covered by accessory buildings, parking garages, carports, and utility and storage sheds shall not be included in this calculation. (h) Minor Modification. Minor modifications to some of the dimensional standards in this section may be available through the minor modification process in Section 20.06.080(a) (Minor Modification), which may be approved by staff during the petition process without the need to apply for a variance, provided that the criteria in Section 20.06.080(a) are met.
(Amd. of 1-14-2020; Ord. No. 21-15, § II (Att. A), 4-21-2021; Ord. No. 21-18, § II (Att. A), 4-21-2021; Ord. No. 21-22, § II (Att. A), 4-21-2021; Ord. No. 22-08, § II(Att. A), 5-18-2022; Ord. 22-10, § II(Att. A), 5-18-2022; Ord. No. 23-04, § 2(Att. A), 4-19-2023; Ord. No. 23-06, § 2(Att. A), 4-19-2023; Ord. No. 2024-03, § II(Att. A), 4-10-2024; Ord. No. 2024-04, § II(Att. A), 4-10-2024; Ord. No. 2025-12, § II(Att. A), 5-21-2025; Ord. No. 2026-08, § 2(Att. A), 5-20-2026; Ord. No. 2026-09, § 2(Att. A), 5-20-2026)
Ask a question about Bloomington law
Corpus searches the Bloomington sections it holds and shows the ones that match, with their citations. Free, no sign-in.
