For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20.04.070 — Site and building design

Code of Ordinances, City of Bloomington, Indiana (Supp. No. 51, Update 1: codified through Ordinance No. 2026-15, passed July 17, 2026) · Bloomington Municipal Code § 20.04.070

Corpus is an independent public-information project, not the official City of Bloomington website. Stable reference: corpuslaw.us/code/68548c98-45ed-41b0-8f20-455b180ce437

20.04.070 - Site and building design.

(a) Purpose. The intent of this Section 20.04.070 (Site and Building Design), is to establish site and building design standards that foster high-quality, attractive, and sustainable development that is compatible with Bloomington's principles and policies. The standards are further intended to: (1) Protect and enhance the character and quality of Bloomington's neighborhoods; (2) Protect and enhance the long-term market value of property within Bloomington; (3) Enhance the human and pedestrian scale of new developments and ensure compatibility between residential neighborhoods and adjacent nonresidential uses; (4) Mitigate negative visual impacts arising from the scale, bulk, and mass of large buildings and centers; (5) Promote building designs and construction practices that are sustainable and adaptable to multiple uses for extended building lifecycles; (6) Minimize negative impacts of on-site activities to adjacent uses; and (7) Balance the community's economic and aesthetic concerns. (b) Applicability. (1) Compliance with this Section 20.04.070 (Site and Building Design) shall be required pursuant to Section 20.04.010 (Applicability) and the specific applicability criteria established in Sections 20.04.070(c) (MD District) through 20.04.070(e) (Projects Abutting to Historic Buildings). (2) Any exterior renovation of a building shall comply with this Section 20.04.070 (Site and Building Design) for the portions of the building affected by the renovation. If the renovation is proposed for only a portion of a building, the Planning and Transportation Director may waive compliance with the site and building design standards if that renovation would be inconsistent with the overall design of the existing structure. (c) MD District. (1) Generally. Notwithstanding subsections (d) and (e) below, all construction activity shall be subject to the design standards set forth in the applicable Downtown Character Overlay as specified in Section 20.02.030(g) (MD: Mixed-Use Downtown) and Section 20.02.060(a) (DCO: Downtown Character Overlay District). (2) Street Lighting Plans in the MD District. All certified street lighting plans proposed for the MD district shall be consistent with the design recommendations of the City of Bloomington Downtown Vision and Infill Strategy Plan and shall comply with the following: (A) Generally. i. Pedestrian scaled street lighting shall be provided as approved by the Board of Public Works. ii. Pedestrian scaled street lighting shall not exceed fifteen feet in height. Additional street lighting may be required, as determined to be necessary by the City Engineer and approved by the Board of Public Works. (B) Lighting Fixture Styles. i. Lighting fixture styles shall generally conform to the prevailing pattern of street lighting found on adjacent properties and street block faces. ii. All pedestrian scaled street lighting in the MD district shall be of a traditional design style (gas lamp, acorn, or similar decorative style) except as otherwise provided below. iii. Properties in the following Downtown Character Overlays may use traditional or contemporary design styles: 1. Downtown core; 2. University village (excluding Kirkwood Corridor and Restaurant Row); 3. Downtown gateway; and 4. Showers technology. (d) Building Design. (1) Third-Party Review. The Planning and Transportation Director may retain an independent third-party consultant to review any proposed building design in order to assist with review of compliance with the standards in this Section 20.04.070(d) (Building Design). Where the decision on an application is made by the Plan Commission or City Council (as shown in Table 06-1), the consultant may offer alternative compliant design option(s) that addresses each element of building design addressed in this Section 20.04.070(d) (Building Design). The body making the final decision on the application may approve some or all of the suggested design options if it determines that the suggested option: (A) Significantly enhances the visual appeal of the building; (B) Significantly enhances the perceived quality of the building facades visible from public streets; (C) Creates no adverse impacts on surrounding properties beyond those that would be permitted if the standards in this Section 20.04.070(d) (Building Design) were applied; and (D) Strengthens the public-private interaction at the street level. (2) Mixed-Use and Nonresidential. (A) Applicability. The following standards shall apply to parcels in the MN, MM, MC, MS, ME, MI, and MH zoning districts. (B) Exceptions. Single-family detached, duplex, triplex, and fourplex dwellings shall not be subject to the architectural standards of this Section 20.04.070(d)(1) (Third Party Review). Such residential dwelling units shall be subject to the architectural standards in Section 20.04.070(d)(3) (Residential). (C) Materials. All facades of a primary building shall consist of one or more of the following primary and secondary exterior finish materials: i. Primary Exterior Finish Materials. 1. Cementitious siding; 2. Masonry; 3. Brick; 4. Natural stone; 5. Precast concrete; 6. Split-faced block; and/or 7. Transparent glass. ii. Secondary Exterior Finish Materials. 1. Wood; 2. EIFS; 3. Metal panel or siding (minimum twenty-six gauge) factory fabricated and finished system with smooth, embossed, or consistent rib pattern and concealed fasteners (except corrugated); or 4. Other products that replicate the appearance and durability of the above materials, as approved by the staff. (D) Exterior Facades. All facades of a primary building shall incorporate three or more of the following design elements in each module to avoid blank, uninterrupted walls, except that buildings less than forty feet in width shall incorporate a minimum of two of the design elements. A module can be a maximum of forty feet in width. i. Awning or canopy that extends at least twenty-four inches from the building face; ii. Change in building facade height in relation to the adjacent modules of a minimum of five feet of difference, except that buildings twenty-five feet or less in height may utilize a minimum of two feet of difference; iii. A regular pattern of transparent glass constituting a minimum of fifty percent of the total wall/facade area of the first-floor facade/elevation and a minimum of thirty percent of each upper floor on each facade/elevation; iv. Wall elevation recesses and/or projections, the depth that are at least three percent of the horizontal width of the building facade and extend from the ground to the top of the building. (E) Patterns. All facades of a primary building visible from any roadway shall contain the following color and texture changes: i. Facades shall consist of at least one primary and one secondary color. ii. At least one of these elements, either texture or color, shall repeat horizontally across the facade. iii. Variations in texture and color elements shall repeat vertically a minimum of every thirty feet. (F) Eaves and Roofs. Buildings with sloped roofs (those greater than three to twelve pitch) visible from any roadway shall contain overhanging eaves, extending no less than two feet past the supporting walls, and consist of shingles, shakes, tile, standing-seam metal, or V-rib metal. Flat roofs (those less than three to twelve pitch) shall include a parapet on supporting walls and may use a flat roof with a rubber membrane or other similar approved material. (G) Three-Hundred-Sixty-Degree Architecture. Those sides of a building that are not visible from the street frontage shall have a finished facade that is similar to the visible facades in terms of materials and architectural detailing. (H) Primary Pedestrian Entry. i. One primary pedestrian entrance shall be provided for every facade facing a street. This includes a sidewalk connection to the adjacent public or private right-of-way. ii. On corner or through lots, the facade facing the higher classified street shall have the primary pedestrian entrance. For purposes of this section, I-69 shall not be used as the higher classified street. iii. The pedestrian entry shall contain at least three of the following architectural details: 1. Pilasters, change in building mass, or a distinct facade module projection; 2. Public art display; 3. Enhanced exterior light fixtures, such as wall sconces or light coves; 4. Raised corniced entryway parapet; or 5. Recessed or framed sheltered element of at least three feet in depth to protect pedestrians from weather; 6. Integral planters or wing walls that incorporate landscaping or seating. (I) Windows on Primary Facades. All first-story windows on the facade of a primary structure shall be transparent and shall not make use of dark tinting or reflective glass. (J) Anti-Monotony Standards. In the case of new construction of multifamily units, any development containing more than three individual buildings shall incorporate the following variations to break up monotony in design: i. Differences in rooflines; ii. Differences in building footprint; iii. Differences in the number of floors per building. (K) Street Addresses. i. Street address displays shall consist of Arabic numerals (e.g., one, two, three…) no less than eight inches in height. For multifamily uses, the address display shall be a minimum of five inches and a maximum of ten inches in height. ii. Street address displays shall be placed above all exterior entrances visible from a public street, private drive, or parking lot. iii. All street addresses shall contrast with the color of the surface on which they are mounted, shall consist of reflective materials, and shall be clearly visible and identifiable from the street. (3) Residential. (A) Applicability. The following standards shall apply to the construction, expansion, addition, or alteration of any building in the R1, R2, R3, R4, RM, RH and RMH zoning districts. (B) Materials. Primary exterior finish building materials used on residential dwellings shall consist of any of the following: i. Horizontal lap siding (e.g., vinyl, cementitious, wood); ii. V-grooved tongue-and-groove siding; iii. Wood-grained vertical siding materials in a board-and-batten or reverse batten pattern; iv. Cedar or other wood materials; v. Stucco, plaster, or similar systems (excluding EIFS); vi. Stone; vii. Split face block, ground face block, or brick; viii. Cast or cultured stone; ix. Cast in place concrete; x. Earthen structural materials; xi. Metal panel or siding (minimum twenty-fix gauge) factory fabricated and finished system with smooth, embossed, or consistent rib pattern and concealed fasteners (except corrugated); or xii. Other materials that replicate the look and durability of the above materials, as approved by the staff. (C) Minimum Coverage. Exterior finish building materials listed above, or a combination of such materials, shall extend from roofline to within six inches of finished grade. (D) Foundations. All buildings shall be placed on permanent foundations. (E) Roofs. i. For attached and detached single-family dwellings, duplex, triplex, fourplex, and multifamily dwelling units that have sloped roofs, the roof shall consist of shingles, shakes, tile, standing-seam metal, or V-rib metal. Additions to attached or detached single-family dwelling units may use flat roofs (less than a three to twelve roof pitch) with a rubber membrane or other similar approved material. ii. Primary structures larger than one thousand square feet of gross floor area may use a flat roof (less than three to twelve roof pitch) with a parapet and shall comply with any applicable standards established in Section 20.03.030 (Use-Specific Standards). (F) Rain Gutters and Downspouts. Rain gutters and downspouts are required. (G) Uniform Architecture. When the rear or side facade of a newly constructed building is adjacent to a street, the architecture of these facades shall be made to match that of the front facade. Such matching shall occur through use of similar materials, window/doorway openings, variation in rooflines, or fenestration. (H) Patterns. In the case of new construction of multifamily units in the RM and RH zoning districts, all facades of a primary building visible from any roadway shall contain the following color and texture changes: i. Facades shall consist of at least one primary and one secondary color. ii. At least one of these elements, either texture or color, shall repeat horizontally across the facade. iii. Variations in texture and color elements shall repeat vertically a minimum of every thirty feet. (I) Primary Pedestrian Entry. In the case of new construction of multifamily units in the RM and RH zoning districts, the following standards shall apply: i. One primary pedestrian entrance shall be provided for every facade facing a street. ii. On corner or through lots, the facade facing the higher classified street shall have the primary pedestrian entrance. For purposes of this section, I-69 shall not be used as the higher classified street. iii. The pedestrian entry shall contain at least three of the following architectural details: 1. Pilasters, change in building mass, or a distinct facade module projection; 2. Public art display; 3. Prominent building address, building name, and enhanced exterior light fixtures such as wall sconces or light coves; 4. Raised corniced entryway parapet; or 5. Recessed or framed sheltered element of at least three feet in depth to protect pedestrians from weather; 6. Integral planters or wing walls that incorporate landscaping or seating. (J) Exterior Facades. In the case of new construction of multifamily units in the RM and RH zoning districts, all facades of a primary building shall incorporate three or more of the following design elements in each module to avoid blank, uninterrupted walls, except that buildings less than forty feet in width shall incorporate a minimum of two of the design elements. A module can be a maximum of forty feet in width. i. Awning or canopy that extends at least twenty-four inches from the building wall to which it is attached; ii. Change in building facade height in relation to the adjacent modules of a minimum of five feet of difference, except that buildings twenty-five feet or less in height may utilize a minimum of two feet of difference; iii. A regular pattern of transparent glass constituting a minimum of fifty percent of the total wall/facade area of the first-floor facade/elevation facing a street for nonresidential uses; iv. A regular pattern of transparent glass constituting a minimum of thirty percent of the total wall/façade area of the first-floor facade/elevation facing a street for residential uses; v. Wall elevation recesses and/or projections, the depth that are at least three percent of the horizontal width of the building façade; vi. Projecting porches, balconies, or entry stoops at relevant elevations. (K) Anti-Monotony Standards. In the case of new construction of multifamily units, any development containing more than three individual buildings shall incorporate the following variations to break up monotony in design: i. Differences in rooflines; ii. Differences in building footprint. (4) Refuse and Recycling Containers. Except for single-family, duplex, triplex, and fourplex dwellings, all uses shall provide adequate space on site for refuse and recycling containers. Such areas shall comply with the standards in Section 20.04.080(m)(3) (Loading, Service, and Refuse Areas). (5) Neighborhood Transition Standards. (A) Setbacks. Buildings abutting a property in the R1, R2, R3, or R4 zoning district shall comply with the minimum building setback of the adjacent Residential zoning district along the common property line or the minimum building setback of the zoning district where the building is located, whichever is greater. When adjacent to the R1, R2, R3, or R4 zoning district, the minimum setback shall be increased by one foot for each foot of building height over thirty feet. (B) Building Height. i. Any portion of a building within fifty feet of a property in the R1, R2, R3, or R4 zoning district shall not exceed the maximum building height allowed in the abutting residential district or the maximum building height of the zoning district where the building is located, whichever is lower. Where a lot abuts two or more residential districts, the residential district with the lowest maximum building height shall govern. Portions of buildings within fifty feet are not eligible for additional building height under Section 20.04.110 (Incentives). ii. Any portion of a building between fifty feet and one hundred feet of a property in the R1, R2, R3, or R4 zoning district shall not exceed the maximum building height allowed in the abutting residential district, plus one story (not to exceed fifteen feet); or the maximum building height of the zoning district where the building is located, whichever is lower. Where a lot abuts two or more residential districts, the residential district with the lowest maximum building height shall govern. Portions of buildings between fifty feet and one hundred feet are not eligible for additional building height under Section 20.04.110 (Incentives). iii. Any portion of a building beyond one hundred feet from a property in the R1, R2, R3, or R4 zoning district shall not exceed the allowed building height of the zoning district where the building is located. Portions of buildings beyond one hundred feet are eligible for additional building height under Section 20.04.110 (Incentives). iv. Building features referenced in Table 04-7 (Authorized Exceptions to Height Requirements), shall be designed to minimize visibility from adjacent residential districts and fit within the allowed building height of the zoning district where the building is located, to the maximum extent practicable. [image omitted; see the official code] Figure 3.2 E: Building Height in Transition Areas (6) Street Addresses. (A) Street address displays shall consist of Arabic numerals (e.g., one, two, three…) no less than three inches in height. (B) Street address displays shall be placed on the front of the structure and on the mailbox post where mailboxes are located along the street. (C) All street addresses shall contrast with the color of the surface on which they are mounted, shall consist of reflective materials, and shall be clearly visible and identifiable from the street. (e) Projects Abutting to Historic Buildings. The following standards shall apply to all facades of primary buildings in the MS, MN, MM, MC, ME, MI, MD, and MH zoning districts that are visible from the road frontage: (1) Building Height Stepdowns. Buildings abutting the side of outstanding and/or notable structures as identified in either one or both of the City of Bloomington Survey of Historic Sites and Structures or the Indiana State Historic Architectural and Archaeological Research Database shall incrementally step down upper stories at each respective facade module to within one story or fourteen feet, whichever is less, above the highest elevation of the respective abutting historic structure. (2) Alignment with Setbacks. Notwithstanding the provisions of Section 20.04.020 (Dimensional Standards), new buildings abutting the side of an outstanding and/or notable structure as identified in either one or both of the City of Bloomington Survey of Historic Sites and Structures or the Indiana State Historic Architectural and Archaeological Research Database shall align their respective facades to match the front setback established by a surveyed structure rather than the required build-to line. (3) Alignment with Belt Courses. Where a building facade is required to incorporate horizontal belt course elements pursuant to Section 20.02.060(a)(8)(A) (Belt Courses), the required horizontal elements shall visually align with similar horizontal design elements of abutting historic structures. (4) Belt Courses. (A) Building facades shall incorporate exterior horizontal belt course design elements for the building base, middle and cap through techniques such as copestone, dripstone, string course, water table, and/or plinth using natural stone or masonry. (B) Building facades shall incorporate exterior vertical banding techniques using natural stone or masonry to visually define building subdivisions of wall planes, modules, or building facade focal points. (f) Universal Design. (1) In multifamily residential buildings and student housing and dormitory buildings constructed after April 18, 2020 that contain more than twenty-five dwelling units, at least twenty percent of the dwelling units shall incorporate at least one entrance at grade level and not requiring any steps up or down or a ramp for entry. (2) In addition, one of the following additional elements of "universal design" is required: (A) All interior doorways with at least thirty-two-inch wide openings; (B) At least one bathroom with thirty-two-inch counter height; (C) At least one bathroom with wall reinforcements for handrails; and/or (D) All light switches installed between forty-four and forty-eight inches in height. (g) Solar Ready Building Design. All new construction of primary structures shall meet either (1) or (2) below: (1) Design building as solar or renewable energy ready and incorporate the following into the site plan: (A) Roof load bearing specifications shall be sized to bear the weight of a solar installation; (B) The roof shall be oriented to maximize solar capacity and roof types shall be compatible with solar installation mounting; (C) Non-solar rooftop equipment (HVAC systems, chimneys, vents) shall be placed to avoid shading of solar equipment and maximize the amount of continuous roof space; (D) Electrical panels shall be sized to accommodate a future solar system and space shall be allocated in the utility room o outside for a solar DC-AC inverter; and (E) Conduit for wiring shall be placed from the roof to the electrical panel. (2) Submit a completed U.S. EPA Renewable Energy Ready Home Solar Site Assessment or another approved solar-ready assessment is required. Modifications to either (1) or (2) above can be approved by the Director of Planning and Transportation.

(Amd. of 1-14-2020; Ord. No. 21-15, § II (Att. A), 4-21-2021; Ord. No. 21-18, § II (Att. A), 4-21-2021; Ord. No. 21-22, § II (Att. A), 4-21-2021; Ord. No. 22-10 § II(Att. A), 5-18-2022; Ord. No. 23-04, § 2(Att. A), 4-19-2023; Ord. No. 23-06, § 2(Att. A), 4-19-2023; Ord. No. 2024-03, § II(Att. A), 4-10-2024; Ord. No. 2024-04, § II(Att. A), 4-10-2024; Ord. No. 2025-12, § II(Att. A), 5-21-2025; Ord. No. 2026-08, § 2(Att. A), 5-20-2026; Ord. No. 2026-09, § 2(Att. A), 5-20-2026)

Ask a question about Bloomington law

Corpus searches the Bloomington sections it holds and shows the ones that match, with their citations. Free, no sign-in.