For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20.04.090 — Outdoor lighting

Code of Ordinances, City of Bloomington, Indiana (Supp. No. 51, Update 1: codified through Ordinance No. 2026-15, passed July 17, 2026) · Bloomington Municipal Code § 20.04.090

Corpus is an independent public-information project, not the official City of Bloomington website. Stable reference: corpuslaw.us/code/83dbf17b-a7bf-44e3-a868-dc5180e41ee5

20.04.090 - Outdoor lighting.

(a) Purpose. The lighting standards are intended to encourage lighting practices and systems that conserve energy and resources; minimize light pollution, glare, and light trespass while maintaining nighttime safety, security, and enjoyment of property; and curtail the degradation of the nighttime visual environment; and to minimize disturbance to sensitive plants and animals. (b) Applicability. Compliance with this Section 20.04.090 (Outdoor Lighting) shall be required pursuant to Section 20.04.010 (Applicability) and the specific applicability criteria established below: (1) Change in Use. If there is any change in use of the property, the provisions of this Section 20.04.090 (Outdoor Lighting) shall apply when the new use commences. Changes in use within multi-tenant centers shall not require the individual tenant or the entire center to comply with the provisions of this section. (2) Modification, Replacement, or Addition of Outdoor Lighting. Modification, replacement or addition of outdoor lighting fixtures constituting twenty-five percent or more of the permitted lumens for the parcel, no matter the actual amount of lighting already on a site, shall trigger compliance for the entire site. (3) Exemptions. (A) Temporary Carnivals and Festivals. Lighting for temporary festivals and carnivals are exempt but shall be turned off within thirty minutes of the last event. (B) Emergency Lighting. Emergency lighting, used by police, fire fighting, or medical personnel, or at their direction, is exempt from all requirements of this Section 20.04.090 (Outdoor Lighting). (C) Traffic Control Lighting. Traffic control lighting is exempt from the provisions of this Section 20.04.090 (Outdoor Lighting). (D) Lighted Flags. Up to three flag poles and flags are exempt from the provisions of this Section 20.04.090 (Outdoor Lighting). All other outdoor lighted flags shall conform to the provisions of this section. (E) Holiday Lighting. Holiday lighting and seasonal decorations using typical unshielded low-intensity incandescent lamps are exempt from the provisions of this section. (F) Low-Intensity Lighting. i. No shielding is required for a light fixture with a bulb rated at two hundred sixty lumens or less. ii. Full shielding is not required for a light fixture with a bulb rated at more than two hundred sixty lumens and less than one thousand lumens when the bulbs are installed inside frosted glass or other translucent covers and shielded on top. iii. The total lumens of bulbs specified in subsections 20.04.090(b)(3)(F)i. and 20.04.090(b)(3)(F)ii. above, when not motion detector activated, shall not exceed two thousand lumens per building, or one thousand lumens per exterior entryway, whichever is less. (G) Swimming Pool and Fountain Lighting. Underwater lighting used for the illumination of swimming pools and fountains is exempt from the lamp type and shielding standards, though it shall conform to all other provisions of this section. (c) General Standards. (1) Conformance with Applicable Codes. All outdoor illuminating devices shall be installed in conformance with the provisions of this UDO and all applicable building and electrical codes. (2) Initial Lumens. For the purposes of this chapter "lumens" means "initial lumens." The acceptability and shielding restrictions applicable to a particular lamp are decided by its initial lumen output, not wattage; check manufacturer's specifications. (3) Prohibitions. (A) Laser Source Light. The use of laser, strobe, and/or flashing source light or any similar high intensity light for outdoor advertising or entertainment is prohibited. (B) Searchlights. The operation of searchlights is prohibited except when used by civil authorities for purposes of public safety. (C) Towers. Tower lighting shall not be permitted unless required by the Federal Aviation Administration (FAA). (4) Light Trespass. (A) All lighting fixtures shall be installed so that light trespass from any property line, except a property line abutting a public street, shall not exceed one footcandle at a point one meter beyond the property line. (B) Properties bordered by R1, R2, R3, R4, or RMH are allowed no more than one-half footcandles at a point one meter beyond the property line adjacent to those districts. (C) Measurements of light readings along any portion of a property line of the subject property shall be taken with a light meter facing the light source at a height of five feet, using any orientation of the light meter. The maximum reading shall be used. (5) Glare. All lighting fixtures shall be installed so as not to cause glare at or beyond the property line and shall not be aimed toward traffic. (A) Shielding. i. All lighting fixtures, except motion detector-activated lighting, shall be fully shielded so that the lighting element is not visible to an observer at any property line, except as stated otherwise in this Section 20.04.090 (Outdoor Lighting). ii. Unless otherwise specified, all lighting fixtures shall be full cutoff type as installed. iii. A lighting fixture may beam light upward only if all upward light is reflected back down by a canopy, roof, or other such structure. iv. Full shielding is not required for motion detector activated lighting of less than one thousand eight hundred lumens, provided the light cycles off no more than ten minutes after coming on. [image omitted; see the official code] Figure 53: Exterior Light Shielding (B) Floodlights and Spotlights. i. Floodlights and spotlights shall be fully shielded so that the light element is not visible to an observer on any property either zoned or used for residential purposes and is not visible to an observer on any public right-of-way. ii. The centerline beam of a floodlight or spotlight shall be aimed no higher than forty-five degrees above vertical; however, light fixtures that cast illumination over more than ninety degrees shall be aimed such that no light shall be cast above the horizontal. (6) Landscape Lighting (A) When planting materials are lighted, high-pressure sodium lamps and low-intensity incandescent lamps shall not be used. (B) Lighting of any tree protection area or conservation easement, including but not limited to those required by Section 20.04.030 (Environment), is prohibited. (d) Multifamily Residential Lighting. A parcel occupied by a multifamily dwelling shall not be illuminated by more than six thousand lumens per primary structure, including a maximum of two thousand lumens per building entryway of any combination of motion detector activated lighting and bulbs rated at no more than one thousand lumens. (e) Mixed-Use and Nonresidential Lighting. (1) Adjacent to Residential Districts. Mixed-use and nonresidential uses bordered by any R1, R2, R3, R4, or RMH zoning district shall be allowed a total light output of not more than forty thousand lumens per acre. Provided, regardless of parcel size, the allowance shall be sufficient to provide a maximum of two thousand five hundred lumens per entryway with motion detector activated lighting counted as one-half lumens. (2) Use-Specific Conditions. (A) Canopies, Pavilions, or Drive-Through Bays. i. Illuminance. The canopy, pavilion, or drive-through bay shall be designed to achieve no greater than the minimal illuminance level of a service station pump island as recommended by the Illuminating Engineering Society of North America (IESNA RP-33: Lighting for Exterior Environments). ii. Shielding. All light fixtures mounted on or recessed into the lower surface of canopies, pavilions, or drive-through bays shall be full cutoff, fully shielded and use flat lenses. Such fixtures shall be recessed so the fixture does not extend below the lower horizontal surface of the canopy, pavilion, or drive-through bay. (B) Outdoor Recreational Facilities. i. Illuminance. All lighting installations shall be designed to achieve no greater than the minimal illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6: Sports and Recreational Area Lighting). ii. Light Trespass. All lighting fixtures shall be installed so that light trespass from any property line, except a property line abutting a public street, shall not exceed two footcandles at a point one meter beyond the property line. iii. Restriction. Field lighting for all outdoor recreational facilities shall be turned off within thirty minutes after the completion of the last event of the night. (C) Parking Lots and Outdoor Display Lots or Areas. i. Illuminance. The parking lot shall be designed to achieve no greater than the minimal illuminance levels for the given land use as recommended by the Illuminating Engineering Society of North America (IESNA RP-33: Lighting for Exterior Environments). However, a parking lot shall also be designed to achieve a minimum illuminance level of one lux. ii. Curfew. Lighting for outdoor display lots and parking lots with more than twenty parking spaces shall be reduced by half no later than eleven p.m., or within thirty minutes after closing of the business, whichever is later.

(Amd. of 1-14-2020; Ord. No. 21-22, § II (Att. A), 4-21-2021; Ord. No. 2024-03, § II(Att. A), 4-10-2024; Ord. No. 2024-04, § II(Att. A), 4-10-2024; Ord. No. 2025-12, § II(Att. A), 5-21-2025; Ord. No. 2026-08, § 2(Att. A), 5-20-2026; Ord. No. 2026-09, § 2(Att. A), 5-20-2026)

Ask a question about Bloomington law

Corpus searches the Bloomington sections it holds and shows the ones that match, with their citations. Free, no sign-in.