§ 15.15.160: Light, ventilation and occupancy limitations.

(A) Scope. The provisions of this section shall govern the minimum conditions and standards for light, ventilation and space for occupying a structure. (B) Responsibility. The owner of the structure shall provide and maintain light, ventilation and space conditions in compliance with these requirements. A person shall not occupy as owner-occupant, or permit another person to occupy, any premises that do not comply with the requirements of this section. (C) Alternative Devices. In lieu of the means for natural light and ventilation herein prescribed, artificial light or mechanical ventilation complying with the building codes listed in EMC § 15.10.010 shall be permitted. (D) Light. (1) Habitable Spaces. Every habitable space shall have at least one window of approved size facing directly to the outdoors or to a court. The minimum total glazed area for every habitable space shall be eight percent of the floor area of such room. Wherever walls or other portions of a structure face a window of any room and such obstructions are located less than three feet from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court and shall not be included as contributing to the required minimum total window area for the room. Exception: Where natural light for rooms or spaces without exterior glazing areas is provided through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight percent of the floor area of the interior room or space, but not less than 25 square feet. The exterior glazing area shall be based on the total floor area being served. (2) Common Halls and Stairways. Every common hall and stairway, other than in one-and two-family dwellings, shall be lighted at all times with at least a 60-watt standard incandescent light bulb or equivalent for each 200 square feet of floor area; provided, that the spacing between lights shall not be greater than 30 feet. Every exterior means of egress stairway, other than in one-and two-family dwellings, shall be illuminated with a minimum of one foot-candle (11 lux) at floors, landings and treads. (3) Other Spaces. All other spaces shall be provided with natural or artificial light sufficient to permit the maintenance of sanitary conditions, and the safe occupancy of the space and utilization of the appliances, equipment and fixtures. (E) Ventilation. (1) Habitable Spaces. Every habitable space shall have at least one openable window. The total openable area of the window in every room shall be equal to at least 45 percent of the minimum glazed area required in subsection (D) of this section. (2) Bathrooms and Toilet Rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by subsection (D) of this section, except that a window shall not be required in spaces equipped with a mechanical ventilation system that complies with the following: (a) Air exhausted by a mechanical ventilation system from a bathroom within a dwelling unit shall be exhausted to the exterior and shall not be recirculated to any interior space, including the space from which such air is withdrawn. (b) Air exhausted by a mechanical ventilation system from all other bathrooms or toilet rooms shall be exhausted to the exterior without recirculation to any space, or not more than 85 percent of the exhaust air shall be recirculated where the system is provided with effective absorption and filtering equipment. (3) Process Ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dust or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any interior space. (4) Clothes Dryer Exhaust. Clothes dryer venting systems shall be independent of all other systems and shall be vented to the exterior and in accordance with the manufacturer’s instructions.

( 1983 Code § 15.150.190 ; Ord. G-2008-29 § 14, passed 12-10-2008 )

Ask a question about Evansville law

Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.