For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.15.170 — Occupancy limitations

Municipal Code of the City of Evansville, Indiana (legislation through 06-22-2026) · Evansville Municipal Code § 15.15.170

Corpus is an independent public-information project, not the official City of Evansville website. Stable reference: corpuslaw.us/code/ca35eb5e-664b-4afe-b228-671d0dd86d54

§ 15.15.170: Occupancy limitations.

(A) Privacy. Dwelling units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces. (B) Area for Sleeping Purposes. Every room occupied for sleeping purposes by one occupant shall contain at least 70 square feet (6.5 m2) of floor area, and every room occupied for sleeping purposes by more than one person shall contain at least 50 square feet (4.6 m ) of floor area for each occupant thereof. (C) Water Closet Accessibility. Every bedroom shall have access to at least one water closet and one lavatory affording privacy and flooring impervious to water so as to permit the floor to be easily kept in a clean and sanitary condition. (D) Overcrowding Prohibited. More occupants than permitted by the minimum area requirements of Table 1 below shall not occupy dwelling units. Table 1MINIMUM AREA REQUIREMENTS Minimum area in square feet** Space | 1 - 2 occupants | 3 - 5 occupants | 6 + Living room* | No Req. | 120 | 150 Dining room* | No Req. | 80 | 100 Kitchen | 50 | 50 | 60 Bedrooms | Shall comply with subsection (B) of this section * See subsection (E) of this section for combined living room/dining room spaces. ** One square foot = 0.093 m2. (E) Combined Spaces. Combined living room and dining room spaces shall comply with the requirements of Table 1 above, if the total area is equal to that required for separate rooms and if the space is located so as to function as a combination living room/dining room. (F) Prohibited Occupancy. Kitchens, uninhabitable spaces and interior public areas shall not be occupied for sleeping purposes. (G) Minimum Ceiling Heights. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a clear ceiling height of not less than seven feet (2,134 mm). Exceptions: (1) In one-and two-family dwellings, beams or girders spaced not less than four feet (1,219 mm) on center and projecting not more than six inches (152 mm) below the required ceiling height. (2) Basement rooms in one-and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a ceiling height of not less than six feet eight inches (2,033 mm) with not less than six feet four inches (1,932 mm) of clear height under beams, girders, duct and similar obstructions. (3) Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a clear ceiling height of at least seven feet (2,134 mm) over not less than one-third of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a clear ceiling height of five feet (1,524 mm) or more shall be included. (H) Minimum Room Widths. A habitable room, other than a kitchen, shall not be less than seven feet (2,134 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than three feet (914 mm) between counter fronts and appliances or counter fronts and walls. (I) Food Preparation. All spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage. Flooring should be constructed and maintained so as to be reasonably impervious to water and so as to permit the floor to be easily kept in a clean and sanitary condition. (J) Efficiency Unit. Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: (1) A unit occupied by not more than two occupants shall have a clear floor area of not less than 220 square feet (20.4 m2). A unit occupied by three occupants shall have a clear floor area of not less than 320 square feet (29.7 m2). These required areas shall be exclusive of the areas required by subsections (J)(2) and (3) of this section. (2) The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided. (3) The unit shall be provided with a separate bathroom containing a water closet, lavatory, and bathtub or shower. (4) The maximum number of occupants shall be three. (K) Emergency Escape and Rescue Openings. Every sleeping room shall have at least one openable emergency escape and rescue window or exterior door opening for emergency escape and rescue. Where openings are provided as a means of escape and rescue they shall have a sill height of not more than 44 inches above the floor. The net clear opening dimensions required by this section shall be obtained by the normal operation of the window or door opening from the inside. Escape and rescue window openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with subsection (O) of this section. (L) Minimum Opening Area. All emergency escape and rescue openings shall have a minimum net clear opening of 4.75 square feet for one-and two-family dwellings and 5.7 square feet for all others. Exception 1: Grade floor openings shall have a minimum net clear opening of 4.75 square feet for one-and two-family dwellings and five square feet for all others. Exception 2: Existing dwellings shall comply with subsection (K) of this section. (M) Minimum Opening Height. The minimum net clear opening height for all emergency escape and rescue openings shall be 24 inches. In order to comply with subsection (L) of this section, the minimum opening width for a 24-inch height is 28.5 inches. (N) Minimum Opening Width. The minimum net clear opening width shall be 20 inches. In order to comply with subsection (L) of this section, the minimum opening height for a 20-inch width is 34.5 inches. (O) Window Wells. The horizontal dimensions of a window well shall allow the emergency escape and rescue opening to be fully opened. The horizontal dimensions of the window well shall provide a minimum net clear area of nine square feet with a minimum horizontal projection and width of 36 inches. Exception: The ladder or steps required by subsection (P) of this section shall be permitted to encroach a maximum of six inches into the required dimensions of the window well. (P) Ladder and Steps. Window wells with a vertical depth greater than 44 inches shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or rungs shall have an inside width of at least 12 inches, shall project at least three inches from the wall and shall be spaced not more than 18 inches on center vertically for the full height of the window well. (Q) Security. Bars, grilles or screens placed over emergency escape windows shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the window.

( 1983 Code § 15.150.191 )

Ask a question about Evansville law

Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.