§ 15.15.310: Means of exiting.
(A) General. A safe, continuous and unobstructed means of exiting shall be provided from the interior of a structure to a public way. (B) Exit Capacity. The capacity of the exits serving a floor shall be sufficient for the occupant load thereof. (C) Number of Exits. In buildings, every occupied story more than two stories above grade shall be provided with not less than two independent exits. In stories where more than one exit is required, all occupants shall have access to at least two exits. Every occupied story that is totally below grade shall be provided with not less than two independent exits. Exception: A single exit is acceptable under any one of the following conditions: (1) Where the building is equipped throughout with an automatic sprinkler system and an automatic fire detection system with smoke detectors located in all corridors, lobbies and common areas. (2) Where the building is equipped throughout with an automatic fire detection system and the exit is an approved smoke-proof enclosure or pressurized stairway. (3) Where an existing fire escape conforming to the building code is provided. (4) Where the occupant load is less than 10 persons and where a window can be utilized for escape because of its size and location. (D) Arrangement. Exits from dwelling units, rooming units and dormitory units shall not lead through other such units, or through toilet rooms or bathrooms. (E) Exit Signs. All means of exiting shall be indicated with approved “Exit” signs where required by the building code. All “Exit” signs shall be maintained visible and illuminated when required by the building code. “Exit” signs shall be illuminated at all times that the building is occupied when required by the building code. (F) Corridor Enclosure. All corridors serving an occupant load greater than 30 and the openings therein shall provide an effective barrier to resist the movement of smoke. All transoms, louvers, doors and other openings shall be closed or shall be self-closing. Exceptions (1) Corridors in occupancies other than hazardous occupancies which are equipped throughout with an automatic sprinkler system. (2) Corridors that are in compliance with the building code. (G) Dead-End Travel Distance. All corridors that serve more than one exit shall provide direct connection to such exits. The length of a dead-end corridor shall not exceed 20 feet where the building is not equipped throughout with an automatic sprinkler system. The dead-end travel distance limitation shall be increased to 40 feet where the building is equipped throughout with an automatic sprinkler system. (H) Stairways, Handrails and Guardrails. Every exterior and interior flight of stairs having more than three risers shall have at least one handrail. Every open portion of a landing, balcony, porch, deck, ramp or other walking surface which is more than 30 inches above the floor or grade below shall have guardrails. Handrails shall not be less than 34 inches nor more than 38 inches high, measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. Guardrails shall not be less than 36 inches high above the floor of the landing, balcony, porch, deck, ramp or other walking surfaces in one-and two-family dwellings and 42 inches in all others. Balusters or intermediate supports on guardrails shall be spaced to prevent the passage of a four-inch sphere. (I) Information Signs. A sign shall be provided at each floor landing in all interior stairways more than three stories above grade, designating the floor level above the floor of discharge. All elevator lobby call stations on all floor levels shall be identified by approved signs in accordance with the requirements for new buildings in the building and fire codes. Exception: The emergency sign shall not be required for elevators that are part of an accessible means of exiting complying with the building code.
( 1983 Code § 15.150.205 ; Ord. G-2008-29 § 15, passed 12-10-2008 )
Ask a question about Evansville law
Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.