§ 18.130.160: Solar energy systems for on-site consumption, ground, roof or building mounted.
(A) Compliance with the limited standards and requirements specific to on-site consumption systems (having a solar array of less than 10 acres in size) established herein allows installation of such a system without obtaining an improvement location permit as long as the energy generated is at least partially used on site for the principal use. (B) Size for Ground-Mounted Systems. (1) Systems for on-site consumption with a solar array of 10 acres or more shall meet the requirements for large-scale systems in EMC §§ 18.130.170 and 18.130.190, and Chapter 18.145 EMC. (2) For systems in the A, R-1 or R-2 districts where the lot or parcel contains a principal residential structure, the solar array shall not be larger than the footprint of the structure unless: (a) The system is located on a lot or parcel of two and one-half acres or more, in which case the array may exceed the footprint of the structure, but shall not exceed 5,000 square feet; or (b) The system is on a lot or parcel that also contains an active agricultural use. (C) Location. Solar energy systems for on-site consumption are permitted in all zoning districts; however, ground-mounted systems shall be prohibited in certain settings as described below: (1) In front yard setbacks, and in side yard setbacks on the street side of a corner lot; (2) In front of the principal structure or use unless: (a) They are located at least 200 feet from the front property line; or (b) They are located in an AIR, C-4, M-1, M-2, M-3 or W-I district; (3) In any easement or right-of-way; (4) Over an operational septic field unless approved by the Vanderburgh County Health Department; or (5) Within any storm water conveyance system in a manner that would alter or impede water flow into a constructed storm water conveyance system. (D) Height. (1) While roof-or building-mounted solar energy systems are exempt from the height standards of any zoning district, roof-mounted systems that are visible from the right-of-way (excluding alleys) must meet the following additional standards: (a) Systems mounted on pitched roofs shall be no more than 10 inches above the roof as measured parallel to the roof line; and (b) In A, R-1 and R-2 districts, systems mounted on flat roofs shall not exceed five feet above the finished roof when oriented at maximum tilt. (c) In all other districts, systems on flat roofs shall not exceed 10 feet above the roof. (2) Ground-mounted solar energy systems shall not exceed 15 feet in height when oriented at maximum tilt. Systems attached to light or utility poles are exempt from this height requirement, but shall not exceed the maximum height for the zoning district. (3) Solar carports (including the supporting structure and the array) in nonresidential districts shall not exceed 20 feet in height when oriented at maximum tilt. (E) Setbacks (Superseding or in Addition to Those Shown in EMC § 18.130.010, Table A). (1) Roof-or building-mounted solar energy systems shall not project into the front setback of the district in which the lot is located. (2) Solar energy systems may be located in a side yard setback that is not on a street corner, or in a rear yard setback, as long as they meet the following requirements: (a) Roof-or Building-Mounted Solar Energy Systems. The collector surface and mounting devices for solar energy systems shall not overhang the roof of a building to the extent that they project closer than two feet from a property line. Solar collectors mounted on the sides of buildings and serving as awnings are building-integrated systems and are regulated as awnings. Exterior piping for solar hot water systems shall be allowed to extend beyond the perimeter of the building on a side yard exposure except when the structure is built to the property line. (b) Ground-Mounted Solar Energy Systems. The collector surface and mounting devices shall not be located closer than two feet from a side or rear property line, even where there is no minimum district side or rear yard setback. (3) Setback distance should be measured from the nearest corner or edge of the solar energy array to the property line. (F) Visibility. Solar energy systems in residential districts that are visible from the public right-of-way shall meet the following: (1) Roof-mounted systems on pitched roofs shall have the same finished pitch as the roof (does not apply to flat roofs). (2) All solar energy systems using a reflector to enhance solar production shall be designed so that they do not cause glare onto adjacent properties or into the right-of-way where it could present a safety hazard for street traffic. (G) Lot Coverage and Accessory Structure Area. (1) Ground-mounted systems shall be exempt from lot coverage or impervious surface standards where there is vegetation under the collector. (2) Ground-mounted systems shall not count toward any maximum accessory structure area. (H) Other Requirements. Building-integrated solar energy systems are permitted if the building component in which the system is integrated meets all required setbacks, land use, and performance standards for the district in which the building is located.
( Ord. G-2022-5 § 2, passed 6-14-2022 )
Ask a question about Evansville law
Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.