For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.130.170 — Commercial solar energy generating facilities

Municipal Code of the City of Evansville, Indiana (legislation through 06-22-2026) · Evansville Municipal Code § 18.130.170

Corpus is an independent public-information project, not the official City of Evansville website. Stable reference: corpuslaw.us/code/b1247e29-bc15-4bac-bc9a-cc8a6429eb5e

§ 18.130.170: Commercial solar energy generating facilities.

(A) General requirements for commercial solar projects are established herein and apply to both types of commercial solar energy generating facilities: community scale and large scale. (B) Location. (1) Commercial solar energy systems are prohibited in: (a) Front yard setbacks, and in side yard setbacks on the street side of a corner lot; (b) Any easement or right-of-way; (c) Over an operational septic field unless approved by the Vanderburgh County Health Department; or (d) Within any storm water conveyance system in a manner that would alter or impede water flow into a constructed storm water conveyance system. (C) Height. Commercial solar energy generating facilities shall not exceed 20 feet in height when oriented at maximum tilt. (D) Setbacks. (1) Setback distance should be measured from the nearest corner or edge of the solar energy generating facility array (excluding security fencing, screening, or berm) to the property line or the residential structure whichever applies. (2) Property line setbacks between separate parcels which are participating in a solar energy system project, where one of the parcels contains a residence, may be waived upon written agreement of the landowner(s) and such agreement shall be recorded, and a recorded copy provided to the Area Plan Commission as part of any rezoning or special use petitions, or submittals for an improvement location permit application. (E) Screening. (1) Due to the large amounts of land area that can be involved in commercial solar energy generating facilities, two types of landscaped buffers (street and property buffers) with required tree plantings are established herein to help screen these facilities and mitigate any potential impacts. (a) Street Buffer. Along any portion of a solar energy generating facility located adjacent to a street, a landscape buffer with tree plantings is required to be installed and maintained through the life of the project to help enhance the visual appeal of the roadside. The landscape buffer shall comply with the following: (i) It shall be located between the edge of the street right-of-way and the perimeter fencing, and can be within the setback area. (ii) Berms may be incorporated in the buffer area, as long as all plantings are installed along the street side of the berm. (iii) Only trees from the small and medium size tree lists in Appendixes B and C of the Evansville Arboricultural Specifications Manual (hereafter referred to as “the Manual”) shall be planted in a street buffer. (iv) The number of trees required to be planted over the total street frontage shall be calculated at: one tree for every 25 linear feet. (b) Property Buffer. Screening in the form of a landscape buffer with tree plantings is also required to be installed and maintained through the life of the project to help provide transition between the proposed commercial solar energy generating facility and any abutting residential use(s), and to enhance the visual appeal of the site border. The requirements for the property buffer are: (i) The trees shall be located along the length of the common property line between the commercial solar energy generating facility site and an abutting parcel that contains a residence and that does not contain a commercial solar energy generating facility. (ii) Placement of the trees shall also be on the exterior edge of the setback between the property line of the abutting residential property and the perimeter fence. (iii) Only evergreen trees from the tree lists in the appendixes of the Evansville Arboricultural Specifications Manual shall be planted in a property buffer (except for arborvitae trees which are not allowed). (iv) Trees shall be spaced at the minimum separation as recommended in Section 4.4.6 of the Manual (one-third of the mature canopy spread or width as shown on the tree lists) so that at maturity they will generally form a continuous screen. (v) No screening is required when the abutting residential structure is more than 400 feet from the solar array. (vi) Along an improved right-of-way where both types of buffers could be required due to an abutting residence, the property buffer shall supersede, meaning that the street buffer requirement would not apply. (c) General Tree Requirements for Required Plantings. (i) A variety of tree species shall be included (native species preferred). (ii) All tree stock shall be balled and burlapped. (iii) Size at planting – meet specifications in Section 4.2 of the Manual. (iv) Prohibited Trees. No dwarf or multi-trunk trees are allowed. (2) Details on the number and location of tree species to be planted to meet these landscape requirements shall be shown on a landscape plan prepared by a registered landscape architect and submitted to the APC with an improvement location permit application and site plan. The landscape plan drawing shall be reviewed for a recommendation by a temporary member of the site review committee with expertise in trees (arborist) to be appointed by the Director, and considered in the permit approval process. (3) Where there are established trees along the site perimeter, the petitioner may provide documentation that the existing trees provide adequate screening, as an alternative to the required plantings, and any existing trees that will provide buffer screening shall be shown on the landscape plan. The tree expert (arborist) appointed to review the landscape plan must consider whether the use of existing trees provides screening equivalent to or better than the required plantings. (4) The Director may grant waivers or partial waivers of the landscaping requirements where it is reasonable and justified due to specific site conditions or use of existing trees for screening, but only when the appointed tree expert (arborist) recommends that the plantings be waived. (5) Guidance on planting methods and tree maintenance is also included in the Manual. (F) Power and Communication Lines. Power and communication lines running between banks of solar panels and to nearby project electric substations or interconnections with buildings shall be buried underground. (G) Fencing. Perimeter fencing for the site shall not include barbed wire or razor wire designs. (H) Other Standards and Codes. All solar energy system projects shall comply with all applicable local, State and Federal regulatory codes, statutes, ordinances, and permit requirements, including without limitation those addressing building standards, erosion and sediment control provisions, nonpoint pollution discharge elimination system permit requirements and storm water drainage plans. (I) Site Plan and Additional Submittals. In addition to having the appropriate zoning for a commercial solar energy generating facility, an applicant shall submit to the Area Plan Commission an improvement location permit application and a site plan for commercial site review in accordance with EMC § 18.170.010(B), along with the following in regard to a proposed solar project: (1) The site plan shall include: locations for the solar array, landscaping, fencing, power grid to be connected to, the location of the connection and its easements, and any other related equipment/structures on the site. (2) If applicable, commitment letters from the utility company(ies) involved for the purchase of electricity to be generated on the proposed site, and/or interconnection letter/agreement for grid-tied solar energy systems. (3) If required, a landscaping plan and the other plan submittals as specified in this chapter. (4) Normal and emergency shutdown procedures, potential hazards to adjacent properties, public roadways and to the community in general that may be created. (5) A name and phone number of the person responsible for inquiries and complaints throughout the life of the project. The owner/operator shall make reasonable efforts to respond to all inquiries and complaints. (6) Provide a copy of the final construction plans (as-builts) to the APC and to all the site review committee agencies with the required dimensions shown. The Director and the site review agencies will determine whether the as-builts meet requirements for issuance of a certificate of occupancy. (7) It is the responsibility of the owner or operator listed in the application to inform the Area Plan Commission of all changes of ownership and operation during the life of the project, including the sale or transfer of ownership or operation, and to update as needed the contact information for the person responsible to respond to inquiries and complaints. (J) Aviation Protection. For solar projects located within the AIR district, within 500 feet of the boundary of the AIR district, or within approach zones of an airport, the applicant must complete and provide the results of a qualitative glare analysis of potential impact, field test demonstration, or geometric analysis of ocular impact in consultation with the Federal Aviation Administration (FAA) Office of Airports, consistent with the Interim Policy, FAA Review of Solar Energy Projects on Federally Obligated Airports, or its most recent version adopted by the FAA. Documentation of FAA approval of the analysis shall be provided to the Area Plan Commission before an improvement location permit can be issued.

( Ord. G-2022-5 § 2, passed 6-14-2022 )

Ask a question about Evansville law

Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.