Sec. 3-64. - Switches for use with less than six hundred volts.

(a) Each sign shall be controlled by a switch which will open all ungrounded conductors. (b) If transformers are installed inside the building wall, a switch shall be installed at the transformer location. A switch may be installed inside flat or recessed signs or letters if special permission is obtained. In these cases, covers over handholes must be clearly marked with a metal tag to indicate the location of the switch. (c) All switches shall be zero to thirty (0 to 30) ampere knife blade contact, and if mounted outside of the sign, shall be in weatherproof enclosure. An electrically operated magnetically held contactor shall be employed as control switch on all neon signs requiring more than six (6) circuits. (d) The coil circuit shall be controlled by single pole switches in series, one (1) of which shall be located at magnetically held contactor. (e) Where a time switch is used to control a sign, manually operable switch shall be installed ahead or on the outside of the time switch.

(Code 1962, § 21-16)

Ask a question about South Bend law

Corpus searches the South Bend sections it holds and shows the ones that match, with their citations. Free, no sign-in.