§ 90-267 — Service connections
Code of Ordinances of the City of Garden City, Kansas (Codified through Ordinance No. 3053-2026, enacted August 4, 2026. (Supp. No. 36, 1-27, Update 1)) · Garden City Code of Ordinances § 90-267
Corpus is an independent public-information project, not the official City of Garden City website. Stable reference: corpuslaw.us/code/9f4ef08d-5772-4de3-aca3-26a8383d0570
Sec. 90-267. - Service connections.
(a) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: (1) Point of delivery. a. Overhead point of delivery is the point at which the service mast facilities connect to the service drop. b. Underground point of delivery is the point at which the underground service conductors connect to the service terminals of the breakers, located on the service pedestal or transformers. (2) Service conductors means the supply conductors that extend from the main line to the service mast facilities at the structure. (3) Service drop means the overhead service conductors from the last pole or aerial support to the service mast facilities at the structure. (4) Service mast facilities, overhead, means the service conductors between the terminals of the service equipment and a point outside the building, where connected to the service drop. (5) Service entrance conductors, underground, means the service conductors between the terminal of the service equipment and the point of delivery (6) Service equipment means the necessary equipment, consisting of circuit breaker or switch and fuses, and their accessories, located near the point of entrance of supply conductors to a building and intended to constitute the main control and means of cutoff for the supply to that building. (b) General provisions. (1) One service conductor set. A building or other premises served shall be supplied through only one set of service conductors except in conformity with exceptions specified in the National Electrical Code or as specified in this Code. (2) Supply between buildings. The service conductors supplying each building or structure shall not pass through the inside of another building unless these buildings are under single occupancy or management. (3) Metering equipment. a. Meters. The city shall supply and install the proper electric meter for the application. b. Meter sockets. When needed, meter sockets and related metering equipment will be issued by the electric utility. A copy of the approved building permit shall be submitted and kept on file with the electric utility before the equipment will be released. Meter sockets shall be rated for a minimum of 100 amps. The utility reserves the right not to energize an underrated or unapproved meter socket. Damaged meter sockets will be replaced and installed by the owner or agent at no expense to the utility. All meter sockets will be installed by the owner, located at eye level height outside of any structure and shall not be in an enclosed area of the yard. c. The owner will be responsible for the special equipment required for service capacity in excess of 200 amps. 1. For loads exceeding 200 amps or 300 volts but less than 600 volts, meter sockets will be furnished by the utility and installed by the owner or agent. Metering will be instrument transformer rated with instrument transformers furnished by the utility. The owner or agent will furnish and install all necessary conduit from the meter socket to the instrument transformer location. 2. Instrument transformers and associated equipment such as enclosures, racks, poles, cable, terminators, insulators, etc., for primary metering will be furnished and installed by the utility at the expense of the customer on a nonrefundable basis. The owner or agent will install the meter socket (furnished by the utility), and will furnish and install all necessary conduit from the meter socket to the instrument transformer location. 3. The location of the meters shall allow access, at all times, by utility personnel for the purposes of reading meters and maintaining utility-owned equipment. The location shall be on the exterior unless otherwise approved by the utility. Each meter socket shall be plainly and permanently marked to indicate which unit is supplied therefrom. The marking is to be the same as the mailing address for each unit. The owner or developer will be responsible for electricity delivered through unmarked, illegible or incorrectly labeled meter sockets. All expenses incurred by the utility related to correcting improperly labeled meters will be billed to the developer or owner whose responsibility it shall be to pay such expenses within 30 days of receipt of such billing. d. Multiple occupancy (apartments). Where service is provided to individual customers located in a structure designed for multiple occupancy, meters should be grouped for service from a single circuit secondary service. The location of the meters should be grouped for service from a single circuit secondary service. The location of the meters shall allow access, at all times, by utility personnel for the purposes of reading meters and maintaining utility-owned equipment. The location shall be on the exterior for multiple occupancy, unless otherwise approved by the utility. The owner will furnish and install utility approved multiple position meter sockets. Trenches for secondary services to apartment complexes are to be inspected by the building official. e. Mobile home park. Electric facilities will generally be installed on rear lot lines (unless otherwise approved by the utility) to meter pedestals with breakers. The location of the meter shall allow access, at all times, by utility personnel for the purposes of reading meters and maintaining utility-owned equipment. f. Streetlighting will be installed in accordance with the city's design criteria and standards for streets as determined by the engineering department. (c) Residential service standards. (1) Residential subdivision developments within the city will incorporate front-of-lot, or rear-of-lot, underground facilities. Individual building lots within areas within established overhead facilities and rural subdivision developments may incorporate either overhead or underground facilities. a. Line extensions will begin at the closest suitable point of the electric distribution system, as determined by the city. b. The extension will end at the customer's point of delivery and the responsibility for service facilities is: 1. Underground Residential Distribution (URD). The city will own, install, and maintain the primary voltage system including transformers and the secondary voltage system including the metering pedestal or the secondary junction vault. (a) Pedestals. The customer will install, own and maintain the service facilities from the pedestal. These facilities shall be in accordance with the requirements of the National Electrical Code and the city building inspection department. (b) Secondary junction vaults. Where secondary junction vaults have been installed in residential subdivisions in lieu of pedestals, the customer will install the secondary facilities to the home including the meter socket which must be placed on the side of the building within ten feet of the front providing full access to utility personnel. The service cable must be installed in a two-inch PVC conduit, meet the provisions of the National Electrical Code, and pass inspection by the city electric inspector. Upon completion, the city will accept ownership and maintenance of the secondary cable service to the line side of the meter housing. i. If a secondary junction vault has been installed as a part of an individual underground service in an established subdivision with overhead facilities, the vault will serve as the connection point between the utility system and the customer-owned service facilities. ii. The customer will install, own and maintain the service facilities from the secondary junction vault. iii. These facilities shall comply with the requirements of the National Electrical Code and the city building inspection department. (c) Overhead. The city will own, install and maintain the primary voltage system, transformers, and service wiring up to the service mast. The customer will be responsible for maintaining a clear path for the service conductors to pass free of vegetation or any other obstructions. The customer will own, install and maintain the service facilities including the mast, an attachment point for the secondary service wire drop that is secure and provides proper clearance, and associated wiring (and meter pole, if required). These facilities will be in accordance with National Electrical Code requirements. The city reserves the right at its option to remove or replace its property. (2) Connections. (a) Underground service. All connections to city-owned facilities will be made by city personnel. (b) Overhead service. Under standard practice, city personnel will connect the city-owned service drop to the customer-owned mast wiring. (d) Commercial Service Standards. (1) Service standards. (a) New commercial or industrial areas within the city will be constructed using underground electric facilities. Individual building lots within areas with established overhead facilities and areas outside the city limits may incorporate overhead or underground facilities. Underground installations will utilize pad mounted transformers. Overhead installations are limited to a maximum size of 150KVA. (b) Under standard practice, commercial/industrial subdivision designs will incorporate a three-phase primary voltage system with associated tap points. Individual service installations may be either single or three-phase at the builder's option. Available three-phrase voltages will be 120/208 or 277/480 volts. Available single-phase voltage will be 120/240 volts. If supplied by a three-phase installation, 120/208 volts three-phase will be the service standard. (2) Installation and ownership of facilities. (a) Standard services. (1) Underground. The city will own, install and maintain the primary voltage system including transformers. The customer will own, install and maintain the service facilities from the transformer secondary spades in accordance with National Electrical Code requirements. Additionally, the customer must furnish the concrete pad for the transformer per the electric utility specifications. This pad remains the ownership and maintenance responsibility of the customer. (2) Overhead. The city will own, install and maintain the primary voltage system, transformers, and service wiring up to the service mast. The customer will own, install and maintain the service facilities including the mast, an attachment point for the clearance and associated wiring; these facilities will be in accordance with National Electrical Code requirements. (b) Primary metering services. The city will own, install and maintain all primary voltage facilities up to and including the customer's metering point. The customer will own, install and maintain all facilities on the load side of the metering point. All customer facilities will be in accordance with National Electrical Code requirements. (c) Duct rental. In public rights-of-way and easements where construction room is limited the city at its option will install, for rental, two-inch PVC duct. The rental fees will be annualized payment based on running footage. The governing body establishes the rental fee and will review and consider changes every third year from the initial date of January 1, 1995. The rental rate for the first term is $0.40 per foot. (3) Connections of service facilities. (a) Underground service. All connections to city-owned facilities will be made by city personnel. The total number of connections within a three-phase transformer will be limited to eight conductors per phase; within a single-phase transformer, the limit will be six conductors per phase. (1) If more than the allowed number of conductors are required, a separate termination cabinet and associated facilities will be installed at the customer's expense. This cabinet will be owned, installed and maintained by the city and will be the point of attachment for the service. The city will own, install and maintain the wiring between the cabinet and transformer and make all associated connections. The customer will own, install, and maintain the facilities between the cabinet and the service entrance and will make all associated connections. (2) Customer installation must be in accordance with local building codes. (b) Overhead service. Under standard practice, city personnel will connect the city-owned service drop to the customer-owned mast wiring under the inspection provisions outlined in Section 90-268 Subsection (b)(3)d.v. of this section.
(Ord. No. 2207, § 1, 10-8-02)
Ask a question about Garden City law
Corpus searches the Garden City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
