§ 5-1106 — International Energy Conservation Code—Table R402.1.1 amended

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-1106

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/85a017f2-fd36-4dca-857e-731cfc7887de

Sec. 5-1106. - International Energy Conservation Code—Table R402.1.1 amended.

Table R402.1.1 of the 2018 International Energy Conservation Code is hereby amended to read as follows: Table R402.1.2. Insulation and Fenestration Requirements By Component Climate Zone | Fenestration U-Factor b | Skylight b U-Factor | Glazed Fenestration SHGC b,e | Ceiling R-Value | Wood Frame Wall R-Value | Mass Wall R-Value i | Floor R-Value | Basement c Wall R-Value | Slab d R-Value and Depth | Crawlspace c Wall R-Value 1 | NR | 0.75 | 0.25 | 30 | 13 | 3/4; | 13 | 0 | 0 | 0 2 | 0.40 | 0.65 | 0.25 | 38 | 13 | 4/6 | 13 | 0 | 0 | 0 3 | 0.35 | 0.55 | 0.25 | 38 | 20 or 13 + 5 h | 8/13 | 19 | 5/13 f | 0 | 5/13 4 except Marine | 0.35 | 0.55 | 0.40 | 49 | 19 or 13+2 h | 8/13 | 19 | 10/13 | 10, 2 ft. j | 10/13 5 and Marine 4 | 0.32 | 0.55 | NR | 49 | 20 or 13 + 5 h | 13/17 | 30 g | 15/19 | 10, 2 ft. | 15/19 6 | 0.32 | 0.55 | NR | 49 | 20+5 or 13+10 h | 15/20 | 30 g | 15/19 | 10, 4 ft. | 15/19 7 and 8 | 0.32 | 0.55 | NR | 49 | 20+5 or 13+10 h | 15/20 | 38 g | 15/19 | 10, 4 ft. | 15/19 NR = Not Required. For SI: one foot = 304.8 mm. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the installed R-value of the insulation shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: In Climate Zones 1 through 3, skylights will be permitted to be excluded from glazed fenestration SHGC requirements, provided that the SHGC for such skylights does not exceed 0.30. c "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "15/19" means R-15 continuous insulation on the interior or exterior of the home or R-19 cavity insulation at the interior of the basement wall. Alternatively, "15/19" shall be R-13 cavity insulation on the interior of the basement wall, plus R-5 continuous insulation on the interior or exterior of the home. d R-5 shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation R-value for slabs, as indicated in the table. The slab edge insulation for heated slabs shall not be required to extend below the slab. e There are no SHGC requirements in the marine zone. f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1. g Alternatively, insulation sufficient to fill the framing cavity and providing not less than an R-value of R-19. h The first value is cavity insulation, the second value is continuous insulation. Therefore, as an example, "13+5" means R-13 cavity insulation, plus R-5 continuous insulation. i Mass walls shall be in accordance with section R402.2.5. The second R-value applies where more than half of the insulation is on the interior mass of the wall.

(Code 2018, § 5-806)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.