Sec. 5-1110. - International Energy Conservation Code—R403.5.1.1 amended.
R403.5.1.1 of the 2018 International Energy Conservation Code is hereby amended to read as follows: R403.5.1.1 Circulation systems. Heated water circulation systems may be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water.