Sec. 17.10.070. - Protective devices required.

(1) Installation. Approved devices to protect against backflow back-siphonage shall be installed at all fixtures and equipment where backflow or back-siphonage may occur and where a minimum air gap cannot be provided between the water outlet to the fixture or equipment and its flood-level rim. (2) Connections not Subject to Backpressure. Where a water connection is not subject to backpressure, an atmospheric vacuum breaker shall be installed on the discharge side of the last valve on the line serving the fixture or equipment. A list of some conditions requiring protective devices of this kind is given in Table 1, Cross-Connections Where Protective Devices Are Required and Critical Level (C-L) Settings for Atmospheric Vacuum Breakers. Table 1 CROSS-CONNECTIONS WHERE PROTECTIVE DEVICES ARE REQUIRED AND CRITICAL LEVEL (C-L) SETTINGS FOR ATMOSPHERIC VACUUM BREAKERS: Fixture or Equipment | Method of Installation Aspirators and ejectors | C-L at least 6 inches above flood level of receptacle served. Dental units | On models without built-in vacuum breakers—C-L at least 6 inches above flood level rim of bowl. Dishwashing machines | C-L at least 6 inches above flood level of machines. Install on both hot and cold water supply line. Garbage can cleaning machines | C-L at least 6 inches above flood level of machine. Install on both hot and cold water supply lines. Fixture or Equipment (cont'd) | Method of Installation (Cont'd) Hose outlets | C-L at least 6 inches above highest point on hose line. Laundry machines | C-L at least 6 inches above flood level of machine. Install on both hot and cold water supply lines. Steam tables | C-L at least 6 inches above flood level. Tanks and vats | C-L at least 6 inches above flood level rim or line. Trough urinals | C-L at least 30 inches above perforated flush pipe. Fixture urinals | C-L at least 6 inches above top of urinal fixture. Flush tanks | Equip with Approved Anti - Siphon Ball Cock, installed according to manufacturer's instructions. Hose bibs | C-L at least 6 inches above flood level of receptacle served. Critical level (C-L) is defined as the level to which the vacuum breaker may be submerged before backflow will occur. Where C-L is not shown on the preventer, the bottom of the device shall be taken as the C-L. (3) Connections Subject to Backflow. Where a potable water connection is made to a line, fixture, tank, vat, pump or other equipment with a hazard of backpressure or backsiphonage, and an air gap cannot be installed, the Director of Public Works & Utilities may require the use of an approved reduced pressure principle backflow preventer assembly or double check valve assembly. A partial list of such connections is shown in Table 2. Table 2 PARTIAL LIST OF CROSS-CONNECTIONS WHICH MAY BE SUBJECT TO BACKFLOW TABLE INSET: Chemical lines | Pumps Dock water outlets | Steam lines Individual water supplies | Swimming pools Industrial process water lines | Tanks and vats—Bottom inlets Pressure tanks | Hose bibbs The following is a partial list but not limited to those facilities where backflow protection will be required at the service connection as well as within the building, due to extreme hazard, to both the public and private piping system: 1. Hospitals—RP 2. Funeral homes, morgues and mortuaries—RP 3. Medical and dental clinics*—RP 4. Industrial, medical and institutional laboratories—RP 5. Plating and chemical plants—RP 6. Metal manufacturing, cleaning and fabricating—RP 7. Oil and gas production, storage and transmission facilities—RP 8. Breweries and beverage bottling plants—RP 9. Radioactive materials plants—Air Gap 10. Aircraft plants—RP 11. Plastic injection and molding plants—RP 12. Multi-storied buildings with booster pump—DC 13. Fire Systems: Contamination hazard—RP Pollution hazard—DC 14. Car wash facilities—RP 15. Restricted, classified or other closed facilities—RP 16. Facilities in which the piping system cannot be traced—RP * Dental Clinics may submit to professional review approved by the Director of Public Works & Utilities for exception to this requirement if facilities convert to modern dry connections for x-ray, suction, and dental chair applications provided that a professional compliance review shall be completed annually at standard inspection rates. Note: RP = Reduced pressure backflow assembly DC = Double check valve assembly (4) Air gap requirements are contained in Table 3. Table 3 AIR GAP REQUIREMENTS: Fixture | When not Affected by Near Wall (a), (inches) | When Affected by Near Wall (b), (inches) Lavatories and other fixtures with effective opening not greater than 1/2; inch diameter. | 1 | 1½ Sink, laundry trays, gooseneck back, faucets and other fixtures with effective openings not greater than ¾ inch diameter. | 1 ½ | 2½ Over rim bath fillers and other fixtures with effective openings not greater than 1 inch. | 2 | 3 Drinking water fountains, single orifice not greater than 7/16 inch diameter or multiple orifices having total area of 0.150 square inches (area of circle 7/16 inch diameter). | 1 | 1 ½ Effective openings greater than one inch. | 2 × diameter of effective opening | 3 × diameter of effective opening a. Side walls, ribs or similar obstructions do not affect air gaps when spaced from inside edge of spout opening a distance greater than three times the diameter of the effective opening for a single wall, or a distance greater than four times the diameter of the effective opening for two intersection walls. b. Vertical walls, ribs or similar obstructions extending from the water surface to or above the horizontal plane of the spout opening require a greater air gap when spaced closer to the nearest inside edge of spout opening than specified in Note (a) above. In the case of three or more such vertical walls or ribs, the air gap shall be measured from the top of the wall. (5) Backflow prevention devices which are acceptable for the prevention of cross-connection hazards are contained in Table 4. Table 4 BACKFLOW PREVENTION DEVICES ACCEPTABLE FOR THE PREVENTION OF CROSS-CONNECTION HAZARDS: Potential Type of Cross Connection | Degree of Hazard | ACCEPTABLE PROTECTION High | Low | AIR GAP | Reduced Pressure Zone | Double Check Valve | Atmospheric Vacuum Breaker | Pressure/Spill Resistant Vacuum Breaker Direct Water Connections Subject to Back Pressure 1. Tanks and lines: a. Sewage and lethal substances | X | X | X (3) b. Toxic substances (1) | X | X | X (3) c. Non-toxic substance (2) | X | X | X | X d. Water connection to boiler | X | X | X Not Subject to Back Pressure (Back siphonage only) 1. Water connected to receptacles containing toxic substances (1) | X | X | X (3) | X (3) | X (3) 2. Water connected to receptacles containing non-toxic substances (2) | X | X | X | X | X | X 3. Water connected to open tanks used for non-potable purposes | X | X | X | X | X 4. Lawn sprinkler systems | X | X | X | X 5. Coils or jackets used as heat exchangers in compressors, degreasers or other equipment: a. For waste lines | X | X | X b. For toxic substances (1) | X | X | X | X (3) | X (3) c. For non-toxic substances (2) | X | X | X | X | X 6. Flush valve toilets & urinals | X | X | X 7. Tank toilet and urinal tanks | X | X | X 8. Valved outlets or fixtures with hose attachments which may constitute a cross-connection: a. Toxic substances (1) | X | X | X | X * b. Non-toxic substances (2) | X | X | X | X * | X * Non-removable Type. Footnotes to Table 4 (1) Toxic Substance: Materials containing contaminants. (2) Non-toxic Substance: Materials containing pollutants. (3) Subject to prior approval.

(Ord. No. 49-403, § 13, 12-11-2012)

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.