Sec. 26.04.135. - Mobile home park shelters.

(a) General Requirements. Every mobile home park of ten or more mobile home spaces which is constructed after April 15, 1994, shall be provided with above-grade or below-grade storm shelters which shall: (1) Have a minimum floor area of ten square feet for each mobile home space in said mobile home park; (2) Be designed by a licensed structural engineer or architect and built in accordance with plans sealed by said structural engineer or architect; (3) Be designed and constructed to meet all Federal Emergency Management Agency (FEMA) requirements and guidelines if the shelter is located in a floodplain; (4) Be designed and constructed to meet the minimum lighting, ventilation and exiting requirements of the city's currently adopted editions of the Uniform Building Code, Uniform Mechanical Code, Uniform Plumbing Code and National Electrical Code where applicable; (5) Be designed and constructed to meet all applicable requirements of the Americans with Disabilities Act (ADA); (6) Be located no farther than one thousand three hundred twenty linear feet from the furthest mobile home space in the mobile home park; (7) Be designed with a perimeter drainage tile system and sump pump to remove water from the storm shelter (below grade shelter only); and (8) Be designed with an electrical service for lighting with emergency lights. All one hundred twenty-five volt electrical receptacles shall have ground fault circuit interrupter protection, except single outlet receptacles for sump pump or specified equipment are not required to have ground fault circuit interrupter protection. (9) Be marked in such a manner that the shelter is clearly visible to park residents. Signs shall state "storm shelter" with lettering at least six (6) inches in height. (b) Additions to Existing Parks. For any addition of ten or more mobile home spaces to any existing mobile home park, a storm shelter which complies with the general requirements of subparagraph (a) of this section shall be provided to serve such additional spaces. For any addition of fewer than ten mobile home spaces to an existing mobile home park which otherwise complies with the requirements of subparagraph (a) or (e) of this section, there is no requirement that an additional shelter be provided to serve such additional spaces; provided, however, that when two or more such additions of fewer than ten mobile home spaces results in a cumulative addition of ten or more mobile home spaces to a mobile home park which otherwise complies with the requirements of subparagraph (a) or (e) of this section, a storm shelter which complies with the general requirements of subparagraph (a) hereof shall be provided to serve such additional spaces. (1) Restroom Facilities. Restroom facilities in required storm shelters shall be optional. Toilets may be either flush-type operating from normal water supply, chemical or other types as approved by the Wichita-Sedgwick County health department. (2) Access to Shelters. The mobile home park owner, or such owner's designated agent or representative, shall be responsible for making the storm shelter accessible and usable in times of need. Such shelters must be accessible whenever the City of Wichita is in a severe thunderstorm or tornado warning issued by the National Weather Service. It is unlawful for any required storm shelter to be used for storage purposes if such storage reduces the minimum floor area available for shelter of persons below the requirements of subparagraph (a) of this section. (c) Existing Nonconforming Mobile Home Parks. (1) Any mobile home park of ten or more mobile home spaces which has an existing above-grade or below-grade storm shelter as of April 15, 1994, which does not conform with the requirements of this section shall be deemed a nonconforming mobile home park with regard to the requirements for storm shelters and may continue to exist as a nonconforming mobile home park for so long as said existing shelter remains in place and usable; provided, however, that any mobile home spaces added to such park after April 15, 1994, shall require storm shelters as provided in subparagraph (b) of this section. (2) Any mobile home park of twenty or more spaces which existed prior to April 15, 1994, and which had no above-grade or below-grade storm shelter on the mobile home park site as of April 15, 1994, shall be required to provide a storm shelter which complies with the requirements of this section by April 15, 1999; provided, however, that any mobile home spaces added to such park after April 15, 1994, shall require storm shelters as provided in subparagraph (b) hereof, (d) Registration of Existing Shelters. By August 1, 1994, every owner or operator of any mobile home park of ten or more spaces shall submit a site plan and a written statement setting out the number of mobile home spaces in such park and a description of any storm shelters which existed on-site prior to April 15, 1994. This submission shall be made on forms provided by the office of central inspection and shall be annually updated with the mobile home park license renewal to show changes in the number of mobile home spaces and a description of any storm shelters constructed to serve such park.

(Ord. No. 44-699 § 1; Ord. No. 47-050, § 18, 6-2-06)

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.