Sec. 26.04.217. - Manufactured home foundations.

Every new or relocated manufactured home installed after the effective date of the ordinance codified in this section and regulated by this chapter shall have a support system in accordance with the manufacturer's printed instructions complying with the National Home Construction and Safety Standards Act and any regulations promulgated thereunder. It shall be the responsibility of the manufactured home owner or licensed manufactured home installer to demonstrate compliance with this requirement and in the event the owner or licensed manufactured home installer is unable to do so, the manufactured home shall be mounted on masonry piers in the following manner: (a) Foundation footings for piers shall be installed directly under the main frame or chassis of the manufactured home. Foundation footings shall be placed on stable, undisturbed soil from which grass or organic material has been removed, or in controlled fill free of organic material compacted to a minimum load-bearing capacity of 1,000 pounds per square foot. Foundation footings shall consist of no less than one (1) 4-inch thick by 16-inch thick by 16-inch wide by 16-inch long solid concrete block[s] or two (2) 4-inch thick by 8-inch wide by 16-inch long solid concrete blocks with the long dimensions of each block parallel with the steel I-Beam frame. Foundation footings shall have a minimum load-bearing capacity of 2,000 pounds per square foot. Alternate footing materials or designs which have been engineered and tested by an approved testing agency may be authorized by the Superintendent of Central Inspection. (b) Piers less than 30 inches in height, measured from the top of the foundation footing to the bottom of the I-Beam, shall be constructed of either open cell or solid concrete blocks each of which shall be 8 inches wide, 8 inches high and 16 inches long. Open cell blocks shall be installed with the open cells aligned vertically. A solid wood or concrete cap plate of at least one (1) inch nominal thickness and not greater than 4 inches nominal thickness, 8 inches nominal width and 16 inches long shall be placed on the top of each pier, with weather proof shims when needed, fitted and driven tightly between the wood or concrete cap plate and the main frame I-Beam. Such shims shall not exceed one (1) inch in nominal thickness and shall be at least 4 inches nominal width and 6 inches long. Piers shall be installed perpendicular to the I-Beam. Piers shall not be spaced further apart than 8 feet on centers. The main frame shall not extend further than one (1) foot beyond the center line of the end of the piers. Piers shall be spaced so as not [to] be located directly under the axle mounting(s). For any pier over 30 inches in height, measured from the top of the foundation footing to the bottom of the I-Beam, the pier shall be double-tiered with blocks interlocked and capped with solid concrete block[s]. The cap plate shall consist of one (1) 4-inch thick by 16-inch wide by 16-inch long solid concrete block or two (2) 4-inch thick by 8-inch wide by 16-inch long solid concrete blocks. The gap between the cap plate and the main frame may be filled with a piece of solid wood at least one (1) inch in nominal thickness but not greater than two (2) inches nominal thickness, 8 inches nominal width and 16 inches long, centered under the I-Beam. The solid concrete cap [plate] or solid wood piece shall be installed with weather-proof shims, as needed, fitted and driven tightly between the wood or concrete cap plate and the main frame I-Beam. Such shims shall not exceed one (1) inch in nominal thickness and shall be at least 4 inches nominal width and 6 inches in length. Piers shall not exceed 48 inches in height, unless designed and sealed by a registered professional engineer or architect. Substitute footing and pier foundation materials may be approved by the Superintendent of Central Inspection if approved by and installed as required by K.S.A § 75-1231.

(Ord. No. 43-648, § 18, 12-9-97)

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.