For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26.04.190 — Fuel gas

The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 26.04.190

Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/162d91a4-55ac-4711-a85b-af7ec2a59b02

Sec. 26.04.190. - Fuel gas.

(a) Liquefied Petroleum Gas—When liquefied petroleum gas is used, containers for such gas shall not hold more than twenty-five gallons water capacity; shall be the liquefied petroleum gas containers approved by the Interstate Commerce Commission for its intended purpose; and shall be integrally attached to the mobile home or recreational vehicle in a manner approved by the Liquefied Petroleum Gas Association, Inc. In the absence of the heretofore mentioned installation, aboveground or underground containers may be connected to mobile homes if such containers are located on a firm fire resistive base no closer to a mobile home or building as set forth in Chapter 15.02 of this Code. Such containers shall be connected to a mobile home as required by this Code for any permanent structure and shall be equipped with an excess flow valve at the discharge valve of the container. Gas lines shall be buried a minimum of eighteen inches below grade from the container to a point at or below the mobile home. (b) Natural Gas—Natural gas may be connected to mobile homes under the following conditions: (1) All gas lines supplying mobile homes or recreational vehicles shall be of adequate size to provide a sufficient supply of gas that will allow all appliances in the mobile home to operate at their normal rate of capacity; (2) Where a gas utility company supplies gas to individual mobile homes the service line to the mobile home shall be sized as required by the utility serving the same and a meter loop shall be made in accordance with the requirements of said utility company; (3) All gas lines including gas service lines serving the mobile home shall be buried not less than eighteen inches below grade to a point at or below the mobile homes and otherwise be installed in accordance with Chapter 21.16 of this Code; (4) For each individual mobile home there shall be a gas stop cock and an American Gas Association approved flexible connector.

(Ord. No. 38-550 (part))

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.