§ 23-82 — Septage discharge
Code of Ordinances of the City of Brockton, Massachusetts (Codified through Ordinance No. 07-31-2025(2), approved July 31, 2025 (Supp. No. 28)) · Brockton Code of Ordinances § 23-82
Corpus is an independent public-information project, not the official City of Brockton website. Stable reference: corpuslaw.us/code/ff622420-6ffc-48a1-a1f9-5a3a754633c1
Sec. 23-82. - Septage discharge.
(a) Septage discharge limitations. Septage may be introduced into the facility treatment plant only, and only at the location(s) and time(s) designated therefor by the commissioner. No septage load may be discharged without prior consent of the commissioner. All septage discharges must comply with the discharge prohibitions and limitations, and the other requirements, set forth in this article. The commissioner has the authority to prohibit the discharge of hauled industrial wastes. The commissioner also has the authority to require that sources of hauled industrial wastes obtain industrial discharge permits. (b) Septage discharge permits. All persons proposing to discharge septage into the facility treatment plant shall be licensed by the town(s) in which they collect septage, and shall obtain a septage discharge permit from the city. Application for a septage discharge permit shall be made on a form supplied by the commissioner. The septage discharge permit shall be issued for a twelve-month period, and the commissioner is authorized to revoke septage discharge permit for violation of any of the requirements of this article or the conditions set forth in the septage discharge permit. The holder of a septage discharge permit shall file with the city treasurer a certificate of insurance in the sums of fifty thousand dollars/one hundred thousand dollars ($50,000.00/$100,000.00) to cover public liability and a certificate of insurance in the sum of ten thousand dollars ($10,000.00) covering property damage. In addition, a certificate of insurance covering workers' compensation shall be filed. All of the referenced insurance policies shall remain in full force and effect for a period of at least a year from the date of issuance of the septage discharge permit. Said insurance shall indemnify the city against any and all claims, liability or action for damages incurred in or in any way connected with the performance of the work by a hauler, and for or by reason of any acts of omission of said hauler in the performance of its work. (c) Septage load certificate. Each septage load shall be accompanied by a certificate signed by the hauler, showing the name and address of the hauler, the name and address of the source of each septage load, and the volume and waste characteristics of each septage load contained in the load to be discharged. The certificate shall also identify the type of industry (if any) in which each source is engaged, known or suspected waste constituent and whether any wastes are RCRA hazardous wastes. (d) Sampling of septage load. The hauler may be required to provide a sample of the septage load contents, taken in the presence of the facility treatment plant's operator, in order to ensure compliance with applicable standards. The commissioner may require that the nature of the sample be verified before the truck is permitted to unload. If the hauler's load is a composite of waste collected from more than one person or location, the commissioner may require that a sample of each waste collection must be provided for verification. (e) Rejection of septage load. The commissioner is authorized to reject a load of septage proposed for discharge at the facility, for reasons including, but not limited to, the following: (1) The waste is not properly identified as to source and content; (2) There is not sufficient capacity in the facility treatment plant for the load; (3) For protection of the health and safety of the public, facility treatment plant workers, or the environment; (4) The septage was not generated in a town approved by the city for septage discharges at the facility treatment plant. SCHEDULE A LOCAL DISCHARGE LIMITATIONS Parameters | Local Limits | Background Limits* Copper | 0.168 mg/l (interim limit of 0.64 mg/l)** | 0.168 mg/l Lead | 1.24 mg/l | 0.056 mg/l Silver | 1.59 mg/l | 0.01 mg/l Zinc | 4.05 mg/l | 0.293 mg/l Total cyanide | 1.00 mg/l | 0.01 mg/l *Background limits are set for significant industrial users that are non-contributory for certain parameters. The background limits are the non-industrial discharge concentrations. The list of significant industrial users and their respective contributing flows is provided in the city's approved industrial pretreatment program document. **The approved and adopted local limit for copper is 0.168 mg/l. However, an interim local limit of 0.64 mg/l was developed from the interim NPDES limit set for copper in the administrative order dated March 25, 1996. The limit will be reevaluated by the city at the expiration of the administrative order, which requires the city to reduce copper loadings to the facility.
(Ord. No. D395, 10-18-96)
Ask a question about Brockton law
Corpus searches the Brockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.