§ 22.30 — GREEN ROOFS

Code of Ordinances of the City of Cambridge, Massachusetts (Codified through Ordinance No. 2025-8, passed April 7, 2025 (Supp. No. 14)) · Cambridge Zoning Ordinance § 22.30

Corpus is an independent public-information project, not the official City of Cambridge website. Stable reference: corpuslaw.us/code/3bc9bee0-9d64-4279-9514-2f9c16b444ef

22.30 - GREEN ROOFS

22.31 Purpose. The purpose of this Section is to establish standards for the development of green roof systems on new and existing buildings for the purpose of stormwater management, heat mitigation, and access and enjoyment by occupants of a building, and to require new buildings of substantial size to include vegetation and/or solar energy roofing systems on much or most of the available roof area. 22.32 Access. Green Roof Area as defined in Article 2.000 of this Zoning Ordinance may be accessible by means of a roof entrance either for maintenance or for recreational use by building occupants or the general public. If Green Roof Area is intended for recreational use, it shall be designed and maintained to ensure that the vegetation will endure the anticipated use throughout the Green Roof Area's lifetime. 22.33 Types. Green Roof Area shall be classified as one of the three following types: (a) Non-Intensive Green Roof Area shall have a minimum 4-inch layer of growing substrate that requires minimal maintenance, using small, low-growing plant species, particularly succulents. (b) Short Intensive Green Roof Area shall have a minimum 18-inch layer of growing substrate that supports a wider variety of plant types, such as herbaceous and woody plants that are less than two (2) feet tall at maturity. (c) Intensive Green Roof Area shall have a minimum 24-inch layer of growing substrate that supports a wider variety of plant types, such as herbaceous and woody plants that are greater than two (2) feet tall at maturity, and requiring more structural support, irrigation, and maintenance than Short Intensive Green Roof Area. 22.34 Operation and Maintenance Plan. Wherever Green Roof Area is proposed, a long-term operation and maintenance plan shall be created and implemented to ensure that the Green Roof Area functions as designed. The level of detail in these plans should reflect the type of Green Roof Area being proposed, the complexity of the project, and the nature and extent of the impacts that may arise both during and after construction. The owner shall submit the operation and maintenance plan to the Department of Public Works (DPW) for approval before applying for a building permit for any building containing Green Roof Area. DPW shall certify to the Superintendent of Buildings that the operation and maintenance plan has been provided to DPW and approved prior to issuance of a building permit for any Green Roof Area. The Commissioner of Public Works shall have the authority to promulgate regulations for the implementation of this Section. 22.35 Green Roofs Requirement. 22.35.1 Applicability. This Section 22.35, et. seq., shall apply to any new building or structure of twenty-five thousand (25,000) gross square feet or more, except it shall not apply to affordable housing buildings that either are developed under the Affordable Housing Overlay (AHO) as defined in Section 11.207 or have a majority of their units permanently reserved for households at or below 100% of AMI. 22.35.2 Requirement. (a) At least 80% of the roof area of the building as measured in plan view, excluding those portions of the roof listed below, shall be devoted to Green Roof Area, Biosolar Green Roof Area, or Solar Energy Systems. 1. Areas having a slope greater than 3 in 12 or twenty-five percent (25%). 2. Areas designed and managed for use by building occupants or the general public. 3. Vehicular parking decks. 4. Chimneys, water towers, air conditioning equipment, elevator bulkheads, skylights, ventilators and other necessary features appurtenant to buildings which are usually carried above roofs and are not used for human occupancy, in addition to conduit, visual and acoustical screening, access routes for maintenance and service, and other areas that must be clear of obstruction to comply with applicable building and safety codes. (b) In the case of non-residential or mixed-use buildings in which at least half of the Gross Floor Area is devoted to one or more of the non-residential uses listed below (with reference to the Table of Use Regulations, Section 4.30 of this Zoning Ordinance), excluding any municipal buildings, at least 80% of the roof area of the building as measured in plan view, excluding those portions of the roof listed above at 22.35.2(a)(1)-(4), shall be devoted to Green Roof Area or Biosolar Green Roof Area: 1. Transportation, Communication & Utility Uses (Section 4.32); 2. Educational Purposes (Section 4.33-b.); 3. Noncommercial Research Facilities (Section 4.33-c.); 4. Other Institutional Uses (Section 4.33-h.); 5. Office and Laboratory Use (Section 4.34); 6. Retail Business and Consumer Service Establishments (Section 4.35); 7. Open Air or Drive In Retail & Service (Section 4.36); 8. Light Industry, Wholesale Business and Storage (Section 4.37); or 9. Heavy Industry (Section 4.38). 22.35.3 Exemption. The Planning Board may grant a special permit to reduce the required Green Roof Area, Biosolar Green Roof Area, or Solar Energy System below the area required by Section 22.35.2, provided that each square foot so reduced be compensated by a unit price contribution to the Cambridge Affordable Housing Trust. This unit price shall be determined based on the average costs to design, install, and maintain green roofs and rooftop solar energy systems in Cambridge using actual cost figures to the extent possible, shall be subject to annual adjustment based on standard construction cost indices, and shall be calculated, and recalculated approximately every three years, by the Cambridge Community Development Department. All such funds contributed to the Trust shall be dedicated to the design and incorporation of Green Roof Area, Biosolar Green Roof Area, or Solar Energy Systems into new or existing affordable housing developments. 22.35.4 Effective Date. The provisions of this Section 22.35, as adopted on June 1, 2021, shall not apply to structures lawfully in existence or lawfully begun before June 1, 2021, or to a building or special permit issued before June 1, 2021, and shall take effect on June 1, 2021.

(Ord. No. 2020-25, 5-3-2021; Ord. No. 2022-9, 2-24-2023)

Ask a question about Cambridge law

Corpus searches the Cambridge sections it holds and shows the ones that match, with their citations. Free, no sign-in.