§ 22.90 — GREEN FACTOR STANDARD
Code of Ordinances of the City of Cambridge, Massachusetts (Codified through Ordinance No. 2025-8, passed April 7, 2025 (Supp. No. 14)) · Cambridge Zoning Ordinance § 22.90
Corpus is an independent public-information project, not the official City of Cambridge website. Stable reference: corpuslaw.us/code/453780bc-7524-4cd4-abab-bfbf58b8834c
22.90 - GREEN FACTOR STANDARD
22.91 Purpose and Intent. The purpose of this Section is to promote the inclusion of features that have a demonstrable cooling effect on buildings and sites to mitigate urban heat island effect. The performance-based "Green Factor," as defined in Article 2.000, approach is intended to be flexible and provide options that can be tailored to different building and site conditions. It is also intended to work in tandem with other regulations, including existing zoning requirements for open space and permeable area, Green Building Requirements (Section 22.20 of this Zoning Ordinance), stormwater control regulations promulgated by the Department of Public Works (DPW), and other standards. 22.92 Applicability. This Section shall apply to development subject to Section 22.20 Green Building Requirements, and as set forth elsewhere in this Zoning Ordinance. 22.93 Prerequisites. The following requirements shall be met for any development that is required to achieve a minimum Cool Score, as defined in Article 2.000: 22.93.1 High Solar Reflectance Index (SRI) Roof. Where the development involves the construction of a new building roof or replacement of more than 50% of an existing roof, the surface of such roof shall have a minimum initial SRI of 82, with the following exceptions: (a) Roofs with a slope of 2:12 or steeper shall not be subject to a minimum SRI requirement. (b) Components of a Solar Energy System or Green Roof Area, as defined in this Zoning Ordinance, shall not be subject to a minimum SRI requirement. (c) In the case of a locally-designated historic structure, the minimum SRI may be reduced or waived to the extent necessary to comply with the conditions of any Certificate of Appropriateness issued by the Cambridge Historical Commission or by a Neighborhood Conservation District Commission. In the case of a state-designated or federally-designated historic structure, the minimum SRI may be reduced or waived to the extent necessary to comply with a determination of adverse effect by the Executive Director of the Cambridge Historical Commission. 22.94 Calculation. 22.94.1 Cool Target. The Cool Target shall be determined by multiplying the total lot area of the lot or Development Parcel by the total Open Space requirement applicable in the zoning district, or by 20%, whichever is greater (see formula below). The Cool Target shall be expressed in square feet. Total Lot Area x Open Space Requirement (min. 20%) = Cool Target 22.94.2 Cool Area. The Cool Area shall be determined by multiplying the building and site design features listed in the table below (as defined in Article 2.000 of this Zoning Ordinance) by the corresponding weighted values in the table. Features that are located within 20 feet of a street shall use the weighted values in the rightmost column; all other areas shall use the weighted values in the column to the left. The Cool Area for a lot or Development Parcel shall be the sum of the weighted values for all such features located on the lot or Development Parcel, expressed in square feet. Category | Cooling Design Feature | Weighted Value Not Within 20' of Street | Weighted Value Within 20' of Street Preserved Existing Trees | Understory Tree currently <10' canopy spread | 0.80 x 150 square feet per tree | 1.60 x 150 square feet per tree Canopy Tree currently <15' canopy spread | 0.80 x 700 square feet per tree | 1.60 x 700 square feet per tree Understory Tree currently >10' canopy spread | 1.00 x 150 square feet per tree | 2.00 x 150 square feet per tree Canopy Tree currently between 15' and 25' canopy spread | 1.00 x 700 square feet per tree | 2.00 x 700 square feet per tree Canopy Tree currently >25' canopy spread | 1.20 x 700 square feet per tree | 2.40 x 700 square feet per tree New or Transplanted Trees | Understory Tree | 0.60 x 150 square feet per tree | 1.20 x 150 square feet per tree Canopy Tree | 0.70 x 700 square feet per tree | 1.40 x 700 square feet per tree Planting Areas | Lawn Area | 0.30 x area in square feet | 0.60 x area in square feet Low Planting Area | 0.40 x area in square feet | 0.80 x area in square feet High Planting Area | 0.50 x area in square feet | 1.00 x area in square feet Green Roofs & Façades | Green Façade | 0.10 x area in square feet | 0.20 x area in square feet Living Wall | 0.30 x area in square feet | 0.60 x area in square feet Non-Intensive Green Roof Area | 0.30 x area in square feet | 0.60 x area in square feet Short Intensive Green Roof Area | 0.50 x area in square feet | 1.00 x area in square feet Intensive Green Roof Area | 0.60 x area in square feet | 1.20 x area in square feet Paving & Structures | Paved Area with a Minimum Solar Reflective Index (SRI) of 33 | 0.10 x area in square feet | Not Applicable Shaded Area | 0.20 x area in square feet | 0.40 x area in square feet 22.94.3 Cool Score. The Cool Score shall be the Cool Area divided by the Cool Target. It shall be expressed as a numerical value that is less than, equal to, or greater than 1.0. (a) A Cool Score of 1.0 or greater shall be considered to meet the Green Factor standard, except as set forth elsewhere in this Zoning Ordinance. (b) Where a development proposal involves the preservation and/or rehabilitation of a pre-existing building on the site, but does not result in an enlargement of the building footprint or expansion of the existing building on the site, then a Cool Score of less than 1.0 shall be considered to meet the Green Factor standard if it is equal to or greater than the Cool Score attributable to the existing conditions on the site. 22.95 Modifications. Upon granting a special permit, the Planning Board may approve modifications to the development standards set forth above after finding that a proposed development is designed to meet the intent of the standards in a manner that is more appropriate to the unique conditions of the development or the site. 22.96 Administrative Review Procedures. Before applying for any special permit from the Planning Board, any development review procedure under Article 19.000 of the Zoning Ordinance, or a Building Permit, whichever occurs sooner, the documentation listed below shall be submitted to the Community Development Department (CDD) for review. Within thirty (30) days after receiving a complete set of documentation, CDD shall provide written notice that the documentation sufficiently demonstrates compliance with the requirements of this Section or shall provide a written explanation of deficiencies to be corrected in a revised submission. To verify continued compliance, revised documentation incorporating any design modifications shall be submitted to CDD and reviewed in accordance with the aforementioned procedures before applying for any Building Permit or Certificate of Occupancy that is sought after the initial submission. (a) Green Factor Score Sheet. A tabulation of the Cool Score of a lot, to be submitted on a form provided by CDD and updated by CDD from time to time. (b) Site and Roof Plans. A set of plans that depict the location and extent of all building and site features identified as contributing to the Cool Score, and also delineate which portions of the lot are within 20 feet of a street. 22.97 Implementation of Green Factor Standard. (a) The Assistant City Manager for Community Development in consultation with the City Engineer may develop standards and procedures appropriate to and consistent with the provisions of this Section. (b) All features used in calculation of the Cool Score shall be designed, installed, and maintained in accordance with such guidelines promulgated by the City. (c) This Green Factor Standard shall become effective ninety (90) days after the date of adoption by the City Council.
(Ord. No. 2022-9, 2-27-2023)
Ask a question about Cambridge law
Corpus searches the Cambridge sections it holds and shows the ones that match, with their citations. Free, no sign-in.
