§ 5-873 — - Steam heating - Piping
Code of Ordinances of the City of Dearborn, Michigan (2026 S-07: Code and Zoning updated through September 22, 2026) · Dearborn City Code § 5-873
Corpus is an independent public-information project, not the official City of Dearborn website. Stable reference: corpuslaw.us/code/000e47b3-acd7-4a32-8ccf-1c6fc1abb74c
Sec. 5-873. - Steam heating - Piping.
(a) Black standard steel or wrought iron pipe with steam pattern cast iron fittings shall be used on all steam heating systems except under special conditions when, if approved by the inspector, other equally safe material may be used. (b) In general, piping shall be arranged to pitch in the direction of flow of steam or condensate and shall be adequately dripped and vented. Maximum pressure drop shall not exceed one-half pound total. (c) As far as possible, boilers shall be located to permit the return of condensate by gravity to the boiler and on such gravity systems, a check valve or Hartford loop shall be installed in the main return to the boiler. On cast iron boilers of the exterior return drum type, the main return shall be branched at the boiler to connect to each such drum. (d) Equalizer of the size, at least one-half the diameter of the boiler tappings, of the main steam load shall be provided from the main supply of the boiler to the wet return connection at the boiler in each case, but in no case shall such equalizer be less than two inches in diameter. (e) In one or two pipe gravity steam heating systems, the low point of the steam main or "dry" return shall be at an elevation not less than 27 inches above the normal boiler water line. (f) No piping shall be laid in any coal bin unless protected by suitable tile or other approved material to keep piping from direct contact with coal. (g) No steam or return piping shall be buried directly in concrete without protection by tile pipe and waterproofed covering with drain at end of the crock pipe, nor shall wet return piping other than threaded cast iron pipe or standard brass pipe having not less than 85 percent copper content be buried below or in concrete floors. All trapped returns must have a full size plugged tee or drain cock at lowest point. (h) In building of frame construction where steam pipes are installed with two inches of wood joints, studs, flooring or other combustible construction, they shall be protected by asbestos or other insulation material not less than three-fourths inch in thickness. (i) Steam and return piping shall be run to permit expansion and contraction without putting any undue strain on pipe or fittings using swing joints or expansion joints to accomplish the above. (j) No cutting of girders, beams, joists, studs or other structural members to permit passage of heating pipes will be permitted, except as approved by the building inspector. (Ord. No. 81-65, § 7.8, 11-4-81)
Ask a question about Dearborn law
Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.