§ 5-888 — - Mechanical warm air heating
Code of Ordinances of the City of Dearborn, Michigan (2026 S-07: Code and Zoning updated through September 22, 2026) · Dearborn City Code § 5-888
Corpus is an independent public-information project, not the official City of Dearborn website. Stable reference: corpuslaw.us/code/c4218e90-1a77-41cd-a355-d2f6f4e38524
Sec. 5-888. - Mechanical warm air heating.
The requirements of this section shall apply to the construction, application and installation of air duct systems and self-contained units employing mechanical means for the movement of air and used for forced air heating systems. (1) A mechanical warm air heating plant shall consist of one or more warm air furnaces enclosed within casings, together with necessary appurtenances thereto, consisting of warm air supply pipes and fittings, cold air or recirculating pipes, ducts, boxes and fittings, smoke pipes and fittings, dampers and registers, faces and grilles, fans or blowers, the same being intended for heating the buildings in which they may be installed. The circulation of air within such a system shall be dependent upon the motive power furnished by a fan or blower, and the duct work in connection therewith shall be designed especially for such system; provided, however, that the incorporation of a booster fan, blower or any power driven device for the purpose of accelerating the air circulation in a gravity warm air heating plant shall be construed as changing the classification of such gravity system to a mechanical system. (2) The amount of air to be provided for each room or space to be heated or conditioned shall be determined in accordance with the Technical Code for the Design and Installation of Mechanical Warm Air Heating Systems, as published by the National Warm Air Heating and Air Conditioning Association, with amendments thereto. (3) A warm air all year air conditioning system shall include a mechanical warm air heating plant, such as defined in section 5-883(2), together with such other devices and such automatic controls as will secure simultaneous control of the temperature, motion and humidity and a reduction in the dust and odor content of the air employed in the ventilation of rooms, but not provided with such devices and automatic controls as will provide for cooling and dehumidifying in summer. (Ord. No. 81-65, § 7.22, 11-4-81)
Ask a question about Dearborn law
Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.
