§ 3.30 — Wind energy
Code of Ordinances of the City of Kentwood, Michigan (Codified through Ordinance No. 6-26, adopted June 2, 2026. (Supp. No. 18)) · Kentwood Code of Ordinances § 3.30
Corpus is an independent public-information project, not the official City of Kentwood website. Stable reference: corpuslaw.us/code/7d07e893-ff5c-40f9-837c-2c5dbc83c332
Section 3.30. - Wind energy.
A. Intent and purpose. 1. It is the intent and purpose of this regulation to promote the safe, effective and efficient use of small wind energy systems installed to reduce the on-site consumption of utility supplied electricity. B. Definitions. As used in this section, the following terms shall have the indicated meanings: Anemometer: A device to measure wind speed. Small wind energy system: A wind energy conversion system consisting of a wind turbine, a tower and associated control or conversion electronics, which has a rated capacity of not more than 100 kW and which is intended to primarily reduce on-site consumption of utility power. Tower height: The height above grade of the fixed portion of the tower, excluding the wind turbine itself. Wind energy system height: The total height of the entire wind energy system including the top of the blade in its vertical position. C. General requirements. 1. Small wind energy systems are permitted as an accessory use in all zoning districts. 2. Height. a. In residential and open space districts, towers of up to 30 feet would be permitted uses. Towers greater than 30 feet in height up to a maximum of 60 feet would be a special land use (see Section 13.04). b. In commercial and office districts, towers of up to 45 feet in height would be permitted uses. Towers greater than 45 feet in height up to a maximum of 60 feet would be a special land use (see Section 13.04). c. In industrial districts, towers up to 60 feet in height would be permitted uses. Towers greater than 60 feet in height up to a maximum of 120 feet would be a special land use (see Section 13.04). d. In all zoning districts, rooftop mounted systems extending not more than 15 feet above the existing roofline are permitted uses. Any rooftop system extending more than 15 feet above and existing roofline would be a special land use (see Section 13.04). 3. Setback. The tower setback shall be the height of the system, including the top of the blade in its vertical position; no other part of the system, guy wires for example, can extend closer than ten feet to a lot line. 4. Location. In residential districts small wind energy systems mounted on towers are restricted to the rear yard. In commercial and industrial districts small wind energy systems mounted on towers are be permitted in rear or side yards. Towers located in the front yard of commercial or industrial district may be permitted as a special land use. 5. Anemometer towers. The same restrictions for height, location and setback that apply to wind energy systems also apply to anemometer towers (MET) which are used to conduct a wind site assessment for possible installation of a small wind energy system. 6. Noise. Small wind energy systems shall not exceed 60dBA, as measured at the closest neighboring inhabited dwelling. This level may be exceeded during short-term events such as utility outages and/or severe wind storms. 7. Construction codes. Utility systems including towers shall comply with all applicable state construction and electrical codes and local building permit requirements, Federal Aviation Administration requirements, the Michigan Airport Zoning Act (Public Act 23 of 1950, MCL 259.432 et seq.), the Michigan Tall Structures Act (Public Act 259 of 1959, MCL 259.481 et seq.), the Gerald R. Ford International Airport Zoning Ordinance height and lighting requirements, applicable utility, Michigan Public Service Commission, and Federal Energy Regulatory Commission interconnection standards. The minimum FAA lighting standards shall not be exceeded. All tower lighting required by the FAA shall be shielded to the extent possible to reduce glare and visibility from the ground. 8. Safety. All small wind energy systems shall have an automatic braking, governing, or feathering system to prevent uncontrolled rotation or over speeding. All wind towers shall have lightning protection. If a tower is supported by guy wires, the wires shall be clearly visible to a height of at least six feet above the guy wire ground anchors. The minimum vertical blade tip clearance from grade shall be 20 feet for a wind energy system employing a horizontal axis rotor. 9. Number. Properties in residential district are limited one small wind energy system. Properties in commercial, office and industrial districts are limited to two small wind energy systems per building.
(Ord. No. 11-08, § 3, 8-29-2008)
Ask a question about Kentwood law
Corpus searches the Kentwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.
