For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-5-3 — Grease interceptors

Code of Ordinances of the City of Rochester, Minnesota (Codified through Ordinance No. 4589, enacted June 1, 2026 (Supp. No. 8, Update 2)) · Rochester Code of Ordinances § 12-5-3

Corpus is an independent public-information project, not the official City of Rochester website. Stable reference: corpuslaw.us/code/966e70cf-34be-4139-8fba-b6fe9c3ef810

Sec. 12-5-3. - Grease interceptors.

(a) Waste pretreatment that complies with this chapter is required before an FSE may discharge fats, oils, or grease into the POTW. (b) Except as otherwise provided in this section, any FSE shall discharge all greasy waste from fixtures or sources in food preparation or cleanup areas, including floor drains, trough drains, floor sinks, mop sinks, pre-rinse sinks, and three-compartment (scullery) sinks, through which fats, oils, or grease may be discharged into the POTW into a properly maintained and functioning grease interceptor that complies with the installation and sizing requirements of the plumbing code as adopted by the state and in compliance with this chapter. (1) When a gravity grease interceptor is installed, the discharge from commercial dishwashers, garbage disposals, and prep sinks shall also flow into the gravity grease interceptor. (2) Commercial dishwashers not discharging into a gravity grease interceptor shall have an associated three-compartment sink or a sink large enough to accommodate immersion of the largest equipment and utensils installed to allow for the collection of greasy waste. (3) Garbage disposals or food grinders are prohibited in new construction or renovation of a structure designed to house an FSE with a hydromechanical grease interceptor. (c) Except as otherwise provided in this chapter, new FSEs proposed or constructed after the effective date shall be equipped with a grease interceptor that complies with the requirements of the plumbing code as adopted by the state and this chapter prior to commencement of any discharge into the POTW. (d) Any permitted construction shall be deemed compliant upon issuance of a certificate of compliance or certificate of occupancy for such construction by the city building official or designee. (e) Any new structure designed for or intended to be used for an FSE must have a gravity grease interceptor installed prior to discharging any wastewater into the POTW. Such grease interceptor must be constructed on the property occupied by the structure in a location outside of any building which allows unrestricted access at any time to city representatives for the purposes of inspection, sampling and testing. Such grease interceptor must comply with all plumbing code requirements as adopted by the state. If the owner of any FSE or of any structure in which an FSE is located or to be located demonstrates to the reasonable satisfaction of the manager that installation of a gravity grease interceptor is not feasible, the manager may grant an exemption allowing such owner to install hydromechanical grease interceptors or other alternative treatment technology which will in the managers discretion adequately control the release of FOG from the FSE or the structure into the POTW. The FSE bears the burden of demonstrating that the installation of a grease interceptor is not feasible. (f) Except as otherwise provided in this chapter, existing FSEs that are not equipped with a grease interceptor or that are equipped with a grease interceptor that does not comply with the most recent plumbing code as adopted by the state, shall install a compliant grease interceptor on a date deemed appropriate by the manager after initial inspection of the FSE, when any of the following applies: (1) An FSE within a building or facility that exists on the effective date and application is thereafter made for a building or plumbing permit at the FSE; (2) There is a change of ownership of an FSE within a building or facility that exists on the effective date; (3) The FSE discharges necessitate increased maintenance on the POTW in order to keep stoppages from occurring therein as determined by the manager; or (4) An FSE is not adequately retaining FOG when quantities above FOG discharge limits of 100 milligrams per liter are found by use of an EPA-approved method for testing oil and grease in wastewater. (g) Existing FSEs that are not equipped with a grease interceptor shall pay a surcharge fee of $50.00 per month for additional services required to remove and treat the addition of excessive FOG to the POTW. FSEs that have obtained an exemption for grease interceptor installation; excluding exemptions granted under section 12-5-4(4), are not subject to the $50.00 surcharge fee until there is a change in operations that affects FOG discharge or until section 12-5-3(f) applies. FSEs that have obtained an exemption under section 12-5-4(4) are subject to the $50.00 surcharge fee.

(Code 1965, § 76C.03; Ord. No. 4453, § 2, 12-6-2021; Ord. No. 4489, § 1, 2-6-2023)

Ask a question about Rochester law

Corpus searches the Rochester sections it holds and shows the ones that match, with their citations. Free, no sign-in.