Sec. 12-5-6. - Operation, maintenance and cleaning of grease interceptors.
(a) The building owner or operator of an FSE that is required to pass wastewater through a grease interceptor shall operate and maintain the grease interceptor so that wastewater exiting the grease interceptor shall not exceed the discharge limit of 100 milligrams per liter of FOG or cause POTW buildup of FOG. (b) The building owner or operator of the FSE shall cause the grease interceptor to be cleaned as hereinafter required when FOG and solids reach 25 percent of the design liquid depth of the grease interceptor, or sooner if necessary to prevent carry-over of grease from the grease interceptor into the POTW. If, prior to cleaning, FOG and solids have exceeded 25 percent of the design liquid depth in the grease interceptor, cleaning frequency must be increased. At a minimum, all grease interceptors shall be cleaned and inspected at three-month intervals. (c) FSEs that have an extended shutdown of operations or have a minimal discharge of grease may submit to the manager for an exception to clean their grease interceptor at a frequency less often than every three months. (d) All personnel cleaning a grease interceptor must complete the course of training offered by the manager in the cleaning of grease interceptors and maintain certification. (e) Any person who cleans a grease interceptor shall do so in accordance with the following procedures and requirements. The person cleaning the grease interceptor shall: (1) Measure and record the depths of solids on the bottom and FOG on the top of the grease interceptor. Also, record the total percent of FOG and solids compared to the design liquid depth. (2) Completely empty and remove the contents (liquids and solids) of all vaults of the grease interceptor, and remove the grease mat and scrapings from the interior walls. (3) Dispose of waste and wastewater removed from a grease interceptor at the wastewater utility or at a facility approved for disposal of such waste. Waste and wastewater removed from a grease interceptor shall not be discharged to any public or private sanitary or storm sewer system. (4) Not deposit waste and wastewater removed from a grease interceptor back into the grease interceptor from which the waste or wastewater was removed or into any other grease interceptor for the purpose of reducing the volume of waste and wastewater to be disposed of. (5) Not introduce enzymes, emulsifying chemicals, hot water or other agents into a grease interceptor to dissolve or emulsify grease or as a grease abatement method. Introduction of bacteria as a grease degradation agent is permitted with prior written approval by the manager. (6) Not use an automatic grease removal system to clean a grease interceptor without prior written approval of the manager, and if, the use of an automatic grease removal system is approved, shall operate same in a manner that the grease wastewater discharge limit, as measured from the system's outlet, is consistently achieved. (f) As part of each cleaning of a grease interceptor, the building owner or operator of the FSE, or the licensed waste hauler employed by the building owner or operator, shall perform the following maintenance activities: (1) Check that the sanitary tees on the inlet and outlet sides of the grease interceptor are not obstructed, loose, or missing. (2) Verify that the baffle is secure and in place. (3) Inspect the grease interceptor for any cracks or other defects. (4) Check that lids are securely and properly seated after completion of cleaning. (5) Check that the flow restrictor is secure. (6) Completely fill out the cleaning and maintenance log sheet provided by the manager and kept at each FSE. (g) The manager may make exceptions to the above requirements, or may approve alternative operational requirements or cleaning and maintenance methods, provided that such exceptions or approvals shall be made in writing by the manager.
(Code 1965, § 76C.06; Ord. No. 4453, § 4, 12-6-2021)
Ask a question about Rochester law
Corpus searches the Rochester sections it holds and shows the ones that match, with their citations. Free, no sign-in.